Schneider Electric I/O & Function Modules
Schneider Electric TM3DI8
Digital Input Module
Genuine surplus Schneider Electric TM3DI8 digital input module — 8 channels, 24 Vdc, verified condition and practical lead times from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module Type | Digital input |
|---|---|
| Channels | 8 |
| Signal Type | 24 Vdc, sink/source (Type 1 per IEC 61131-2) |
| Input Range | 24 Vdc nominal, 19.2–28.8 Vdc |
| Input Current | 7 mA per channel (at 24 Vdc) |
| Response Time | 4 ms max. (turn on/off) |
| Isolation | 500 V AC between input and internal logic; no isolation between channel groups |
| Operating Temperature | 0...+55 °C |
| Protection Rating | IP20 |
| Dimensions (H×W×D) | 90 × 27.4 × 84.6 mm |
Description
The Schneider Electric TM3DI8 is an 8-channel, 24 Vdc digital input module for Modicon TM3 expansion systems, used by maintenance and controls teams to add discrete sensing to M221, M241, M251 and M262 platforms. Genuine surplus and refurbished units give buyers a verified alternative when OEM lead times stretch.
What This Module Does in a Modicon TM3 System
The TM3DI8 is a digital input slice: eight channels accept 24 Vdc sink/source signals (Type 1 per IEC 61131-2), with a nominal range of 24 Vdc and an operating window of 19.2–28.8 Vdc. Each channel draws 7 mA at 24 Vdc, and the module responds within 4 ms maximum on turn-on or turn-off — practical for standard discrete sensing such as limit switches, pushbuttons and relay contacts.
Isolation is 500 V AC between input and internal logic, with no isolation between channel groups, so plan field wiring with that grouping in mind. Module status and bus status diagnostics are available for troubleshooting. The removable screw terminal block uses a 5.08 mm pitch, which simplifies field replacement without re-terminating every conductor.

Technical Specs Breakdown
Three specifications drive most selection decisions on this module. First, the 8-channel count and 7 mA per-channel input current at 24 Vdc set the load your sensor circuit must support. Second, the 4 ms maximum response time defines the fastest discrete event the module will report reliably. Third, the 500 V AC input-to-logic isolation and IP20 protection rating frame where the module can be installed — inside a suitable enclosure, across an operating temperature range of 0…+55 °C.
Physically, the unit measures 90 × 27.4 × 84.6 mm and weighs 0.085 kg, so it occupies a single narrow slice on the TM3 bus. Bus current draw is 22 mA at 5 V DC with all inputs off. Power consumption figures are not published for this configuration, so confirm any supply budgeting with our sourcing team before ordering.
Surplus Advantage and Sourcing Guidance
Because This unit is listed as Active (last verified 2026-09), buyers have two routes: new from the OEM channel, or genuine surplus and refurbished stock from Autronexa. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, which keeps the cost position practical without gambling on unverified grey-market stock.
Before ordering, confirm four things: the exact model and any revision markings on the unit, the condition grade you need (surplus versus refurbished), compatibility with your specific Modicon M221, M241, M251 or M262 platform, and the accessory terminal block arrangement. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TM3DI8, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the TM3DI8 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the grade you need when you request a quote.
How fast can Autronexa ship the TM3DI8?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping window before you commit.
Does the TM3DI8 work with my Modicon controller?
The module is compatible with Modicon M221, M241, M251 and M262 platforms per the datasheet. Confirm your exact controller model and firmware revision with our sourcing team before ordering.
Is the TM3DI8 still supported by Schneider Electric?
The datasheet lists the lifecycle as Active, last verified 2026-09. Contact Autronexa to confirm current OEM support status and availability at the time of your order.
Related & compatible parts
Schneider Electric
BMEH584040C
Genuine surplus Schneider BMEH584040C redundant processor for Modicon M580 — verified condition, faster than OEM lead times.
Schneider Electric
ATV310HU22N4E
Genuine surplus Schneider ATV310HU22N4E 2.2 kW drive — verified condition, faster than OEM lead times, with practical sourcing…
Schneider Electric
ATV310HD18N4E
Genuine surplus Schneider ATV310HD18N4E, 18.5 kW heavy-duty drive — verified condition, tested, and ready to ship from Autronexa.
Schneider Electric
TSXP573623AM
Genuine surplus Schneider Electric TSXP573623AM micro PLC with Ethernet TCP/IP and 16-rack capacity — verified and ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…