Schneider Electric I/O & Function Modules
Schneider Electric 140DDI35310C
Discrete Input Module
Genuine surplus Schneider 140DDI35310C: 32-channel 24 V DC discrete input module for Modicon Quantum, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Input Channels | 32 |
|---|---|
| Input Voltage | 24 V DC |
| Input Voltage Limits | 19.2...30 V |
| Input Impedance | 2400 Ohm |
| Response Time | <= 1 ms (state 0 to 1 and 1 to 0) |
| Bus Current Requirement | 330 mA |
| Isolation (group to bus) | 1780 Vrms for 1 minute |
| Ambient Temperature | 0 to 60 °C |
| Protective Treatment | Conformal Coating Humiseal 1A33 |
| Standards | UL 508, CSA C22.2 No 142 |
Description
When a Modicon Quantum rack loses input channels, every hour of downtime adds cost. The Schneider Electric 140DDI35310C discrete input module restores 32 channels of 24 V DC monitoring, and genuine surplus stock gets you back online faster than OEM lead times.
What This Module Does in a Quantum System
The 140DDI35310C is a low-voltage DC discrete input module from Schneider Electric’s Modicon Quantum platform. It provides 32 input channels arranged in four groups of eight, with negative (source) logic and a 24 V DC nominal input. The module occupies two input words in the PLC’s addressing scheme, so commissioning is straightforward for maintenance teams familiar with Quantum I/O.
Each channel includes a green status LED, while a red LED flags external faults and a green LED confirms bus communication. That front-panel visibility helps you trace a failed field device without pulling the module. Input protection is resistor-limited, and the conformal coating (Humiseal 1A33) adds resistance to moisture and dust in industrial cabinets.

Technical Specifications That Matter on the Floor
Three specs deserve attention during troubleshooting. First, response time is <= 1 ms from state 0 to state 1 and = 2.5 mA at Us = – 14 V for state 1 and <= 0.5 mA for state 0 — define how much field current your sensors must sink to register reliably. Third, the module tolerates input voltage limits of 19.2…30 V, with an absolute maximum of 30 V continuous, so check your loop supply against those limits before swapping a module.
Isolation between group and bus is rated 1780 Vrms for 1 minute, and between groups 500 Vrms for 1 minute. The unit draws 330 mA from the bus and operates from 0 to 60 °C ambient. It carries CE marking and meets UL 508 and CSA C22.2 No 142 standards.

Why Genuine Surplus Fits This Module
Quantum installations often run well beyond their original design life, and OEM lead times for legacy I/O can stretch. Autronexa stocks genuine surplus and refurbished Quantum modules, each tested against OEM datasheet specifications and functionally verified by our sourcing team. For a module like this, that means you can replace a failed card without re-engineering the rack or paying full list price. Please verify current lifecycle status and availability with Autronexa before ordering.
Sourcing Checklist for Maintenance Engineers
Before you order, confirm the exact part number and any revision suffix on the existing module, since Quantum I/O has several variants. Decide whether your application needs the conformal-coated version — this unit carries Humiseal 1A33 treatment. Check that your field devices meet the state 1 and state 0 current thresholds above. And ask for the module’s condition grade: surplus versus refurbished. Autronexa provides verified condition details and clear lead times with every quote. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this 140DDI35310C a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the specific condition grade when you request a quote.
How fast can you ship the 140DDI35310C?
Lead time depends on current stock. Contact Autronexa for current availability and lead time; surplus and refurbished units are typically ready to ship faster than OEM factory orders.
Does this module work with my existing Modicon Quantum rack?
The 140DDI35310C is a Modicon Quantum discrete input module with 32 channels and 24 V DC input. Confirm your rack's addressing capacity (it requires two input words) and backplane compatibility before ordering.
Is the 140DDI35310C still supported by Schneider Electric?
Lifecycle status varies. Contact Autronexa to verify OEM support status and current availability for this part number.
Related & compatible parts
Schneider Electric
140DDO35301
Genuine surplus Schneider 140DDO35301: 32-output DC module for Modicon Quantum, verified and ready to ship from Autronexa.
Schneider Electric
140ARI03010
Genuine surplus Schneider 140ARI03010 analog input module for Modicon Quantum — 8 differential channels, verified condition, ready to…
Schneider Electric
ATV320U40N4C
Genuine surplus Schneider ATV320U40N4C 4 kW drive — verified condition, faster than OEM lead time, ready to ship.
Schneider Electric
ATV930U55N4
Genuine Schneider ATV930U55N4 Altivar drive, 5.5 kW ND / 4 kW HD, verified surplus and refurbished stock with…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…