Schneider Electric I/O & Function Modules
Schneider Electric 140EHC20800SC
High-speed counter module
Genuine surplus Schneider Electric 140EHC20800SC high-speed counter module — verified, tested, and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Counting Input Type | Incremental or quadrature |
|---|---|
| Counting Frequency | 500000 Hz |
| Input Resistance | 10 kOhm discrete input |
| Discrete Output Number | 4 |
| Discrete Output Type | Field Effect Transistor (FET) |
| Load Current | 0.5 A |
| Maximum Leakage Current | 0.4 mA state off |
| Protection Type | 36 V transorb discrete output |
| Output Short-Circuit Protection | Blown fuse 2.5 A |
| External Power Requirement | 19.2 to 30 V |
Description
When a Modicon Quantum high-speed counter module fails on a running line, every hour of downtime costs output. The Schneider Electric 140EHC20800SC is a genuine surplus option for maintenance teams that need a verified replacement fast, without waiting on OEM lead times or paying full list price. Autronexa stocks tested, refurbished units with clear condition reporting.
What This Counter Module Does in a Quantum Rack
The 140EHC20800SC is a high-speed counter module for the Modicon Quantum platform. It accepts incremental or quadrature input types, so it fits encoder-based position and speed feedback as well as pulse counting from flow meters and similar devices. The counting frequency reaches 500000 Hz, which matters when a slow scan cycle would otherwise miss fast pulses. Four discrete outputs use Field Effect Transistor (FET) technology and handle 0.5 A load current each, letting the module trigger downstream actions without a separate output card. Input resistance is 10 kOhm for discrete inputs, a practical value that keeps integration straightforward in existing panels.

Protection and Environmental Ratings That Matter on the Floor
From a service standpoint, the protection design is the part worth checking first. Each discrete output carries a 36 V transorb and a 2.5 A blown-fuse short-circuit protection scheme, so a field fault is contained at the module rather than propagating through the rack. Maximum leakage current is 0.4 mA in the off state. The module requires an external supply of 19.2 to 30 V and resists electromagnetic fields to 9.1 V/m, which helps in cabinets near drives and contactors. Operating altitude is rated to 5000 m. During periodic inspection, check output fuses and terminal torque, and follow the manufacturer safety manual for any internal work.

Why Genuine Surplus Fits This Module
Quantum installations are long-lived, and a failed counter card often stops a line while the rest of the rack is healthy. Autronexa sources genuine surplus and refurbished units, each tested against OEM datasheet specifications and functionally verified by our sourcing team. That gives you a practical alternative to OEM lead time and full list price on a module that is already proven in service. Because condition varies by unit, we report it clearly before you commit. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140EHC20800SC, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not copies.
What condition will the module arrive in?
Units are supplied refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition report on the unit available now.
How fast can you ship the 140EHC20800SC?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does this module work with incremental and quadrature encoders?
Yes. The module accepts incremental or quadrature input types and counts at up to 500000 Hz, so it suits encoder feedback as well as pulse counting from other field devices.
Is the 140EHC20800SC still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
BMENOP0300
Genuine surplus Schneider Electric BMENOP0300 communication module for Modicon M580 PACs — verified condition, ready to ship.
Schneider Electric
BMXDDI1604T
Genuine surplus Schneider Electric BMXDDI1604T Modicon X80 16-channel 24 V DC input module with per-channel diagnostics, verified and…
Schneider Electric · Advantys STB
STBACO0120
Genuine surplus Schneider STBACO0120 analog output module — 1-channel 4-20 mA, 15-bit, hot-swappable, verified and ready to ship.
Schneider Electric
PC-E984-258C
Genuine surplus Schneider Electric PC-E984-258C compact CPU — 512K memory, Modbus ports, conformal coating. Verified condition, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…