| Product Compatibility | 140CRA21210, 140CRA21220 |
|---|---|
| Number of Ports | 1 Modbus RS232 twisted pair redundant copper; 2 Modbus Plus RS485 twisted pair redundant copper |
| Transmission Rate | 1 Mbit/s |
| I/O Words | 30 I/32 O |
| Power Dissipation | 4 W |
| Bus Current Requirement | 780 mA |
| Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) |
| Relative Humidity | 95 % without condensation |
| Product Certifications | UL 508, CSA, FM Class 1 Division 2, GOST, GL, RINA, RMRS, DNV, C-tick |
Description
When a Modicon Quantum DIO network stalls, the head-end adaptor is often the first suspect — and the hardest part to source quickly. The Schneider Electric 140NOM21200 is a DIO head-end adaptor for the Modicon Quantum automation platform, compatible with 140CRA21210 and 140CRA21220 remote adaptors. Autronexa supplies this unit as genuine surplus, verified and functionally tested, so you avoid OEM lead times without risking a clone.
What This Adaptor Does in a Quantum System
The 140NOM21200 sits at the head of a distributed I/O drop, linking the Quantum CPU to remote adaptors over redundant copper twisted-pair cabling. It provides one Modbus RS232 port and two Modbus Plus RS485 ports, all on redundant twisted-pair copper, and runs at a transmission rate of 1 Mbit/s. The module handles 30 input and 32 output I/O words. Power dissipation is 4 W with a bus current requirement of 780 mA — figures worth checking against your rack power budget before installation. The adaptor carries UL 508, CSA, FM Class 1 Division 2, GOST, GL, RINA, RMRS, DNV and C-tick certifications, so it fits installations where those approvals are specified.

Surplus Advantage for This unit
Modicon Quantum is a mature platform, and head-end adaptors like this one are increasingly sourced from the surplus market rather than through standard OEM channels. That shift carries risk: unverified units with unknown service history circulate widely. Autronexa’s approach is practical — each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it enters stock. You get a genuine part with a known condition, not a pulled unit of uncertain origin. For maintenance teams holding spares of 140CRA21210 or 140CRA21220 remote adaptors, keeping a verified head-end adaptor on the shelf shortens recovery time when a drop goes down. Please verify current lifecycle status and availability with Autronexa before ordering.

Environmental Limits and Sourcing Checks
The adaptor is rated for operation from 32…140 °F (0…60 °C) and storage from -40…185 °F (-40…85 °C), with relative humidity up to 95 % without condensation and operating altitude up to 5000 m. Its EMC immunity includes 9.1 V/m (10 V/m) across 80…2000 MHz per IEC 801-3, plus 4 kV contact and 8 kV air electrostatic discharge per IEC 801-2. Before you commit, confirm the exact revision on your existing unit, verify that your remote adaptor model matches the compatibility list, and decide whether surplus or refurbished condition suits your spares policy. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 140NOM21200, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before stocking. We supply genuine surplus and refurbished parts, not grey-market copies.
What condition will the 140NOM21200 arrive in?
Units ship in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us if you need a specific condition grade.
How fast can you ship the 140NOM21200?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus units often ship faster than OEM backorder cycles.
Does this adaptor work with my existing remote adaptors?
The 140NOM21200 is listed as compatible with 140CRA21210 and 140CRA21220 remote adaptors on the Modicon Quantum platform. Confirm your exact remote adaptor model before ordering.
Is the 140NOM21200 still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before you plan a replacement.
Related & compatible parts
Schneider Electric
TSXDMZ28AR
Genuine surplus TSXDMZ28AR discrete I/O module for TSX Micro PLCs — 28 channels, DIN rail mount, verified and…
Schneider Electric
170DNT11000
Genuine surplus Schneider Electric 170DNT11000 Profibus DP adaptor for Modicon Momentum — verified condition, ready to ship.
Schneider Electric
ATV930C16N4
Genuine surplus Schneider ATV930C16N4 Altivar 930 drive — 160 kW ND, dual-rated, STO safety, verified and ready to…
Schneider Electric
ATV71HD30N4
Genuine surplus Schneider ATV71HD30N4 30 kW variable speed drive — verified condition, practical sourcing support, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…