Schneider Electric I/O & Function Modules
Schneider Electric 170ADM37012
Module Modicon Momentum
Genuine surplus Schneider 170ADM37012 mixed I/O module — 16 DI, 8 DO, 4 AI, 2 AO. Verified condition, faster than OEM lead time.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 DI + 8 DO + 4 AI + 2 AO |
|---|---|
| Signal type | 24V DC digital, analog configurable |
| Output type | Solid-state switch |
| Supply voltage | 24V DC |
| Power consumption | 8 W maximum |
| Isolation | 500 V AC for 1 min (analog I/O to operating voltage; to ground) |
| Response time | 2.2 ms (input off-to-on), 3.3 ms (input on-to-off), <0.1 ms (digital output) |
| Diagnostics | 1 red LED per output on overload/short-circuit; I/O error reported to bus adapter |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 125 × 141.5 × 47.5 mm |
Description
When a Modicon Momentum I/O base drops offline, the whole control cabinet loses its field signals — and with the 170ADM37012 discontinued, replacement sourcing becomes the bottleneck. Autronexa supplies this Schneider Electric mixed I/O module as genuine surplus, verified before dispatch, so maintenance teams can restore 16 DI, 8 DO, 4 AI and 2 AO channels without waiting on an OEM allocation.
What This Mixed I/O Base Actually Does
The module packs four signal types onto one base: 16 digital inputs, 8 solid-state digital outputs, 4 analog inputs and 2 analog outputs, all on a 24V DC digital platform with analog configurable channels. That density is the practical answer to a crowded cabinet — one base covers the discrete sensing and the analog loop signals a compact Momentum station typically needs. The digital outputs switch solid-state, and each output carries its own red LED that flags overload or short-circuit, while I/O errors are reported up to the bus adapter. Input response sits at 2.2 ms off-to-on and 3.3 ms on-to-off; digital output response is under 0.1 ms. Analog I/O is isolated at 500 V AC for 1 min to operating voltage and to ground, which matters when analog loops share a panel with switching loads.

Why Surplus Fits a Discontinued Module
Schneider lists this unit as discontinued (last verified 2026-09), so the realistic choice is between waiting on remaining OEM channels and buying verified surplus. Autronexa’s refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team — genuine parts, verified, not pulled-and-shipped unknowns. Power draw is 8 W maximum, the housing is IP20 and measures 125 × 141.5 × 47.5 mm at 0.4 kg, so a drop-in replacement keeps panel space and supply loading unchanged. For plants holding several Momentum stations, buying surplus also removes the single-source risk that comes with an end-of-life base module.

Sourcing Checks Before You Order
Confirm the exact model and revision on your existing base, since mixed I/O configurations are not interchangeable across the family. Decide whether you need surplus or refurbished condition and state it on the request. Check that your bus adapter and terminal accessories match the base you are replacing, and verify the analog channel configuration your process expects. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric 170ADM37012, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module is supplied as genuine surplus, not a grey-market copy.
What condition will the module arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus condition can be quoted on request.
How fast can you ship the 170ADM37012?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus and refurbished units are ready to ship once verified.
The module is discontinued — can I still get one?
Yes, through surplus and refurbished channels. Schneider lists this unit as discontinued (last verified 2026-09), so confirm availability with Autronexa before committing to a maintenance window.
Does the analog isolation suit a mixed panel?
The analog I/O is isolated at 500 V AC for 1 min to operating voltage and to ground, per the datasheet. Confirm your panel's grounding practice with your engineer before installation.
Related & compatible parts
Schneider Electric
170ENT11001
Genuine surplus Schneider Electric 170ENT11001 Ethernet TCP/IP adapter for Modicon Momentum — verified condition, faster than OEM lead…
Schneider Electric
TSXP571634
Genuine surplus Schneider Electric TSXP571634 Unity Processor — verified, refurbished, with 512 discrete and 24 analogue I/O capacity.
Schneider Electric
ATV71HD15N4Z
Genuine surplus Schneider ATV71HD15N4Z Altivar 71 drive, 15 kW, 380–480 V AC, verified condition and ready to ship.
Schneider Electric
TSXCANCADD5
Genuine surplus Schneider Electric TSXCANCADD5 CANopen cordset, 5 m, molded SUB-D9, IP20 — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…