| Range of product | Modicon X80 |
|---|---|
| Primary voltage | 100...240 V |
| Supply circuit type | AC |
| Secondary power | 10.8 W 24 V DC sensor; 16.8 W 24 V DC I/O and processor; 8.3 W 3.3 V DC logic |
| Network frequency | 50/60 Hz |
| Protection type | Internal fuse (primary); overload, overvoltage, short-circuit (secondary) |
| IP degree of protection | IP20 |
| Net weight | 0.3 kg |
| Ambient air temperature for operation | 0…60 °C |
Description
The Schneider Electric BMXCPS2000 is a power supply module for the Modicon X80 range, converting AC line supply into the DC rails that X80 I/O modules and processors need. Maintenance teams and automation engineers reach for genuine surplus or refurbished units when an OEM lead time would leave a rack idle. Autronexa supplies verified stock with practical turnaround.
What This Power Supply Does in an X80 Rack
The BMXCPS2000 accepts an AC supply circuit and delivers three secondary outputs: 10.8 W at 24 V DC for sensor power, 16.8 W at 24 V DC for I/O module power and the processor, and 8.3 W at 3.3 V DC for I/O module logic. In practical terms, one module feeds the sensor loop, the I/O backplane, and the logic rail together, which is why a failure takes the whole rack down rather than a single channel.
Primary voltage limits are 85…264 V, and network frequency limits are 47…63 Hz, so the unit tolerates the brownouts and frequency drift common on older plant supplies. Protection covers the secondary circuit against overload, overvoltage, and short circuit, and an internal fuse protects the primary. Two green status LEDs report rack voltage OK and sensor voltage, giving a technician a first-line diagnostic before any meter work. A RESET push-button provides cold restart. The module is not compatible with BMEXBP..02 backplanes, so confirm your backplane reference before ordering.

Why Genuine Surplus Fits This Module
Power supplies are a high-wear item in any rack: they run continuously, carry inrush current at every energisation, and sit behind whatever thermal conditions the enclosure allows. That makes them one of the most frequently replaced X80 components, and one of the most commonly counterfeited. A refurbished unit from Autronexa is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. You get genuine parts, verified, without waiting on a factory allocation.

Sourcing Checklist Before You Buy
Match the exact part number and confirm backplane compatibility — the BMEXBP..02 exclusion is the first thing to check. Decide whether your application needs surplus, refurbished, or new condition, and ask for the condition grade in writing. Verify the electrical connection points you need: the module provides a 2-pin alarm relay connector and a 5-pin connector for line supply, protective earth, and 24 V DC sensor input. Finally, confirm the operating environment: 0…60 °C ambient, IP20 protection, and operation up to 2000 m without derating. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXCPS2000 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the BMXCPS2000 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — ask for the condition grade in writing when you request a quote.
How fast can Autronexa ship the BMXCPS2000?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm verified condition and current availability, then quote a shipping date.
Is the BMXCPS2000 compatible with every Modicon X80 backplane?
No. The module is not compatible with BMEXBP..02 backplanes. Confirm your backplane reference before ordering, and our sourcing team can help you cross-check it.
Is the BMXCPS2000 still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before you commit to a replacement plan.
Related & compatible parts
Schneider Electric
BMXDDM16025
Genuine surplus BMXDDM16025 mixed I/O module — 8 DI + 8 relay DO, verified condition, faster than OEM…
Schneider Electric
TM3AI8
Genuine surplus Schneider TM3AI8: 8-channel, 12-bit analog input module for Modicon M221/M241/M251/M262. Verified condition, ready to ship.
Schneider Electric
BMXDDO1602
Genuine surplus BMXDDO1602 discrete output module — 16 outputs, 24 V DC, verified condition and faster lead time…
Schneider Electric
STBNIP2212
Genuine surplus Schneider Electric STBNIP2212 Modbus TCP/IP network interface module — verified condition, sourcing help, faster than OEM…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…