Schneider Electric I/O & Function Modules
Schneider Electric BMXDAO1605
Discrete output module
Genuine surplus Schneider Electric BMXDAO1605 16-output Triac module, 100–240 V AC, verified and ready to ship from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Output Number | 16 |
|---|---|
| Output Type | Triac |
| Discrete Output Voltage | 100 to 240 Volts AC |
| Discrete Output Current per Channel | 0.6 Amps |
| Inrush Current | 20 Amps |
| Maximum Current per Output Common | 2.4 Amps |
| Protection Type | 1 External Fuse Fast Blow |
| IP Rating | IP 20 |
| Operating Temperature | 0...60 Degrees Celsius |
| Weight | 0.50 lbs (0.23 kg) |
Description
When a Modicon X80 rack loses discrete output control on a running line, every hour of downtime adds cost. The Schneider Electric BMXDAO1605 is a 16-output Triac discrete output module rated for 100 to 240 volts AC, and Autronexa supplies it as a genuine surplus or refurbished unit so you can restore switching without waiting on OEM lead times.
What the BMXDAO1605 Does in a Modicon X80 System
This unit is a discrete output module from Schneider Electric’s Modicon X80 family. It provides 16 Triac outputs, each rated at 0.6 amps, with a 20-amp inrush capability that lets it drive loads with high start-up current without nuisance tripping. The module accepts a discrete output voltage range of 100 to 240 volts AC, so it suits AC switching duties across a range of panel designs. A maximum current per output common of 2.4 amps sets the group limit you need to respect when distributing loads across channels. Protection relies on a 1 external fuse fast blow arrangement, and status LEDs on the module front give at-a-glance channel indication during commissioning and fault finding. The unit is rated IP 20 and specified for indoor use at 0 to 60 degrees Celsius.

Why Genuine Surplus Makes Sense for This Module
Modicon X80 racks are long-lived, and a failed output card often strands a working system while a replacement is ordered. Autronexa holds verified surplus and refurbished stock of these modules, with each unit tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. That means you get the correct 16-channel Triac configuration, the 100 to 240 volts AC rating and the 0.6-amp per-channel capability you expect, without paying a brand-new list price or accepting an unverified grey-market card. Because these are genuine parts, verified, the module drops into the same slot and wiring scheme as the original. Lead times are typically shorter than an OEM factory order, which matters when a line is waiting on one card.

Sourcing Checks Before You Order
Before committing, confirm the exact model on your rack drawing matches This unit and that your load current per channel stays within 0.6 amps, with the 2.4-amp common limit respected across grouped outputs. Check that your AC supply falls inside the 100 to 240 volts AC window and that panel ambient stays within 0 to 60 degrees Celsius. Decide whether you need a surplus unit or a refurbished one; both are available, and condition is stated clearly on each quote. Ask about the external fast-blow fuse arrangement so you have the right protection in place. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this BMXDAO1605 a genuine Schneider Electric module or a clone?
Autronexa supplies genuine surplus and refurbished Schneider Electric modules. Each BMXDAO1605 is checked against OEM datasheet markings and part-number cross-reference before it is listed, so you receive a verified unit rather than an unmarked copy.
What condition will the BMXDAO1605 arrive in?
Units ship in the condition stated on your quote, either surplus or refurbished. Refurbished modules are tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.
How fast can Autronexa ship the BMXDAO1605?
Lead time depends on current stock at the time of order. Contact Autronexa with your part number and we will confirm verified condition and the current availability date before you commit.
Can the BMXDAO1605 drive loads with high inrush current?
Yes. Each Triac output is rated at 0.6 amps with a 20-amp inrush capability, which supports loads that draw a high start-up current. Keep the 2.4-amp maximum per output common in mind when grouping channels.
Is the BMXDAO1605 still supported by Schneider Electric?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
140MMB10200
Genuine surplus Schneider 140MMB10200 motion controller — verified, tested, and ready to ship with sourcing support from Autronexa.
Schneider Electric
TSXCTZ2A
Genuine surplus Schneider Electric TSXCTZ2A counter module for Modicon TSX Micro — 2 inputs, 24 V DC, verified…
Schneider Electric
140NOA61110C
Genuine surplus Schneider Electric 140NOA61110C Interbus module for Modicon Quantum — verified condition, faster than OEM lead time.
Schneider Electric
FBM242
Genuine surplus FBM242 discrete output module — 16 isolated channels, Class G3 rated, verified and ready to ship…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…