Schneider Electric I/O & Function Modules
Schneider Electric BMXSAI0410
Analog input module
Genuine surplus Schneider Electric BMXSAI0410 safety analog input module — 4 isolated 4...20 mA inputs, verified and ready to source.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Analogue input number | 4 |
|---|---|
| Analogue input type | Current 4...20 mA |
| Isolation between channels | Isolated |
| Analogue input resolution | 13 bits, 0...12500 counts |
| Input impedance | 286 Ohm |
| Measurement error | <= 0.3 % of full scale 4...20 mA - 25...60 °C |
| Isolation voltage | 500 V DC between channels; 1500 V DC to ground and bus |
| Net weight | 0.315 lb(US) (0.143 kg) |
| IP degree of protection | IP20 |
Description
What the BMXSAI0410 Does in a Modicon X80 Rack
The Schneider Electric BMXSAI0410 is a safety analog input module for the Modicon X80 platform, carrying four isolated 4…20 mA current inputs for high-level process signals. Maintenance and procurement teams reach for genuine surplus or refurbished units when a channel fails or a spare is needed without waiting on OEM allocation, and Autronexa verifies each unit against OEM datasheet markings before it ships.
Signal Path and Conversion
Each of the four channels accepts a 4…20 mA current loop and converts it with 16-bit analog/digital conversion at 13-bit resolution, giving 0…12500 counts. The module permits 25 mA overload on the 4…20 mA inputs and presents 286 Ohm input impedance, so loop-powered transmitters see a predictable load. A second-order digital filter smooths the reading, and the nominal read cycle time is 6 ms for all four channels together. Measurement resolution is 2 µA, and the digital value format is +/- 32000 in user scale (+/- 10000 by default).
Isolation and Accuracy
Channel-to-channel isolation is rated 500 V DC, with 1500 V DC between channels and ground and between channels and the bus. Minimum crosstalk attenuation is 120 dB. Measurement error is <= 0.3 % of full scale across 4…20 mA at -25…60 °C, and temperature drift is 30 ppm/°C. Recalibration is internal. The module draws 200 mA at 3.3 V DC and 115 mA at 24 V DC, and its MTBF reliability figure is 463000 H.
Surplus Advantage for This Module
Safety-rated analog input modules are rarely stocked deep by distributors, and a single failed channel can hold up a validated loop. Autronexa keeps genuine surplus and refurbished Modicon X80 modules in rotation: each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. That means a verified spare with a clear lead time instead of an open-ended OEM backorder, and cost savings against full OEM list price. Because this is safety-related gear, follow the manufacturer safety manual for inspection and never attempt internal repair. Please verify current lifecycle status and availability with Autronexa before ordering.


Frequently asked questions
Is this BMXSAI0410 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The BMXSAI0410 we supply is genuine Schneider Electric, not a grey-market copy.
What condition will the BMXSAI0410 arrive in?
Our default condition is Refurbished: the module is tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a surplus unit instead.
How fast can you ship the BMXSAI0410?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm lead time before you order.
Does the BMXSAI0410 suit safety-related analog loops?
The module is described as a safety analog input module with four isolated 4...20 mA inputs and carries TÜV, CSA, UL and ATEX certifications. Confirm your specific safety architecture and manual requirements with your engineering team.
Is the BMXSAI0410 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering, and we will confirm OEM support status for you.
Signal Path and Conversion
Each of the four channels accepts a 4...20 mA current loop and converts it with 16-bit analog/digital conversion at 13-bit resolution, giving 0...12500 counts. The module permits 25 mA overload on the 4...20 mA inputs and presents 286 Ohm input impedance, so loop-powered transmitters see a predictable load. A second-order digital filter smooths the reading, and the nominal read cycle time is 6 ms for all four channels together. Measurement resolution is 2 µA, and the digital value format is +/- 32000 in user scale (+/- 10000 by default).
Isolation and Accuracy
Channel-to-channel isolation is rated 500 V DC, with 1500 V DC between channels and ground and between channels and the bus. Minimum crosstalk attenuation is 120 dB. Measurement error is <= 0.3 % of full scale across 4...20 mA at -25...60 °C, and temperature drift is 30 ppm/°C. Recalibration is internal. The module draws 200 mA at 3.3 V DC and 115 mA at 24 V DC, and its MTBF reliability figure is 463000 H.
Surplus Advantage for This Module
Safety-rated analog input modules are rarely stocked deep by distributors, and a single failed channel can hold up a validated loop. Autronexa keeps genuine surplus and refurbished Modicon X80 modules in rotation: each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. That means a verified spare with a clear lead time instead of an open-ended OEM backorder, and cost savings against full OEM list price. Because this is safety-related gear, follow the manufacturer safety manual for inspection and never attempt internal repair. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Schneider Electric · Advantys STB
STBDDI3610
Genuine surplus Schneider Electric STBDDI3610 digital input module — 6 channels, 24V DC, hot-swappable, verified condition and ready…
Schneider Electric
BMXSDI3202
Genuine surplus Schneider Electric BMXSDI3202 Modicon X80 32-channel safety discrete input module, SIL3/PLe rated, verified and ready to…
Schneider Electric
BMXDDO1612
Genuine surplus BMXDDO1612: 16-channel 24V DC transistor output module for Modicon X80, verified and ready to ship.
Schneider Electric
TSX07211622
Genuine surplus TSX07211622 PLC from Schneider Electric — 24 VDC, relay outputs, verified condition and ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…