Technical specifications

Discrete output number 8 EN/IEC 61131-2
Discrete output type Solid state, not isolated
Discrete output voltage 24 V 19...30 V DC
Discrete output current 0.5 A
Current per channel 0.625 A
Maximum current per module 10 A
Response time on output 1.2 ms
Power dissipation in W 4.4 W
IP degree of protection IP20
Product weight 0.26 lb(US) (0.12 kg)

Description

The BMXSDO0802 is a Schneider Electric Modicon X80 discrete output module with eight solid-state, positive-logic 24 V DC outputs rated 0.5 A per channel. Maintenance teams specify this module when they need a genuine, verified replacement for a failed output card without waiting on OEM lead times — surplus and refurbished stock keeps the line running.

What the BMXSDO0802 Does in a Modicon X80 Rack

This module drives eight discrete loads from a Modicon X80 system, switching positive 24 V DC at 0.5 A per channel and up to 10 A per module. Outputs are solid state and not isolated, with a maximum voltage drop of <1.2 V at state 1 and a maximum leakage current of 0.5 mA at state 0 — values that matter when driving sensitive input circuits downstream. The response time on output is 1.2 ms, and outputs can be paralleled two maximum for higher current. Each channel carries its own green diagnostic LED, alongside module RUN, ERR and I/O indicators, so a technician can localise a fault at the rack without a meter. Reverse polarity, overload, overvoltage and short-circuit protection are built in, with a 2 A external fuse specified for short-circuit protection. The module weighs 0.12 kg and operates from -25 to 60 °C.

Figure 1: Front view of the Schneider Electric BMXSDO0802 Discrete output module showing its physical design and enclosure.

Why Genuine Surplus Fits This Output Card

Discrete output modules are wear items in any panel: they take the switching duty and the field faults. When one fails, the priority is a verified replacement, not a purchase order in a queue. Autronexa supplies this module as genuine surplus or professionally refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. That means the eight outputs, the diagnostic LEDs and the protection circuits are checked before dispatch. For maintenance engineers, the practical benefit is a shorter path from fault finding to restart, with clear lead times confirmed at the point of enquiry. The part is returnable per the manufacturer’s schedule, and country of origin is FR.

Figure 2: Technical layout and connection details for the Schneider Electric BMXSDO0802 Discrete output module.

Selection and Sourcing Checks Before You Order

Confirm three things before committing: the exact part number unit, the Modicon X80 rack position and backplane compatibility, and whether your field devices present an IEC 61131-2 type 3 DC input load, which this module supports. Note that the output is not isolated, so review your panel’s grounding arrangement. The module ships with conformal coating and IP20 protection, suitable for a clean control cabinet rather than a washdown area. Because lifecycle status is not stated in our data, please verify current lifecycle status and availability with Autronexa before ordering. Send your part number and rack details and our sourcing team will confirm condition, lead time and price.

Frequently asked questions

Is this BMXSDO0802 a genuine Schneider Electric module or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not copies.

What condition will the BMXSDO0802 arrive in?

Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us if you need a surplus unit in as-removed condition instead.

How fast can Autronexa ship the BMXSDO0802?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm dispatch dates before you order.

Does this module work with IEC 61131-2 type 3 DC input devices?

Yes. The datasheet lists output compatibility with IEC 61131-2 type 3 DC input, and the module is not compatible with standard IEC 61131-2 DC input. Check your field device type before ordering.

Is the BMXSDO0802 still supported by Schneider Electric?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before committing to a maintenance plan.

Related & compatible parts

Schneider Electric

BMEP586040

Genuine surplus BMEP586040 processor module for Modicon M580 — verified condition, faster lead time than OEM, practical sourcing…

In Stock

Schneider Electric · Advantys STB

STBDAI5230

Genuine surplus STBDAI5230 digital input module — 2-channel 115V AC, hot-swappable, verified condition from Autronexa.

In Stock

Schneider Electric

ATV610D11N4Z

Genuine surplus Schneider ATV610D11N4Z, 11 kW drive with C3 EMC filter — verified condition, ready to ship from…

In Stock

Schneider Electric

140CPU53414A

Genuine surplus Schneider Electric 140CPU53414A processor unit for Modicon Quantum — verified condition, ready to ship.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: BMXSDO0802

We reply within one business day.

BMXSDO0802 Quote reply within 1 business day