Schneider Electric Circuit Protection

Schneider Electric iC60N 2P C10

Circuit Breaker

Manufacturer: Schneider Electric Part Number: iC60N 2P C10

Genuine surplus Schneider Electric iC60N 2P C10 10A C-curve breaker — verified condition, clear lead times, practical sourcing support.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Poles 2P
Rated current 10A
Trip curve C (thermal-magnetic, magnetic trip 8×In ±20%)
Breaking capacity 6 kA @ 230/400V (IEC 60898-1)
Rated voltage 400V AC, 125V DC
Mounting 35 mm DIN rail
Operating temperature -35 to 70 °C
Mechanical life 20,000 cycles
Electrical life 10,000 cycles
Dimensions (H×W×D) 85 × 36 × 78.5 mm

Description

When a 10A final circuit trips and will not reset, the bottleneck is rarely the load — it is getting the right breaker back on the DIN rail. The Schneider Electric iC60N 2P C10 is a 2-pole, 10A C-curve miniature circuit breaker from the Acti9 iC60 range, and Autronexa supplies it as genuine surplus or refurbished stock so maintenance teams can restore protection without waiting on a full OEM order cycle.

What This Breaker Does in a Distribution Board

The Acti9 iC60 family is built for final distribution and control-panel protection, and this variant combines two poles in a single 36 mm module. The C trip curve uses thermal-magnetic protection with a magnetic trip at 8×In ±20%, which suits circuits that carry short inrush currents on start-up without nuisance tripping. Rated current is 10A, rated voltage is 400V AC or 125V DC, and breaking capacity is 6 kA at 230/400V under IEC 60898-1. The unit mounts on 35 mm DIN rail, measures 85 × 36 × 78.5 mm, and weighs 0.25 kg. Mechanical life is rated at 20,000 cycles and electrical life at 10,000 cycles, so the operating count is a practical wear indicator during inspection.

Figure 1: Front view of the Schneider Electric iC60N 2P C10 Circuit Breaker showing its physical design and enclosure.

Why Surplus and Refurbished Fits This Model

Lifecycle data lists this breaker as Active in the Acti9 range, verified in September 2026, so it is not an obsolete line. That matters because buyers sometimes assume surplus means end-of-life stock. Here, surplus and refurbished supply is a faster route to a current-production part: units are tested against OEM datasheet specifications and functionally verified by our sourcing team, and lead times are quoted clearly rather than left open. For a panel rebuild or a single failed pole, that can mean getting the board back into service without holding the job for a factory lead time. Genuine parts, verified — that is the standard we apply to every Acti9 unit we move.

Buyer Checklist Before You Order

Start with the exact configuration: 2 poles, 10A, C curve, iC60N breaking capacity of 6 kA. A B-curve or 1-pole unit will not substitute in the same way, so match the printed rating on the existing device. Confirm the busbar and DIN rail arrangement — this module is 36 mm wide on 35 mm rail — and check whether the enclosure expects the Acti9 iC60 profile. Ask for condition grading: surplus versus refurbished changes what documentation you should expect. Autronexa can cross-reference the part number against OEM markings and confirm current availability; contact Autronexa with your part number for verified condition and current availability. Please verify current lifecycle status and availability with Autronexa before ordering.

📄 Download Datasheet: iC60N 2P C10-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric iC60N 2P C10, or a clone?

Autronexa verifies units against OEM datasheet markings and part-number cross-reference before listing. The breaker is supplied as genuine surplus or refurbished stock, not a grey-market copy.

What condition will the breaker arrive in?

The site default condition is Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask Autronexa for the specific grading on the unit reserved for you.

How fast can you ship the iC60N 2P C10?

Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we quote lead times directly rather than leaving them open.

Does this breaker suit a 400V AC panel?

Yes — rated voltage is 400V AC or 125V DC, with 6 kA breaking capacity at 230/400V under IEC 60898-1. Confirm your panel voltage and trip curve before ordering.

Is the Acti9 iC60 range still in production?

Lifecycle data lists this model as Active in the Acti9 range, last verified September 2026. Contact Autronexa to confirm OEM support status at the time of your order.

Related & compatible parts

Schneider Electric

TM3DQ16R

Genuine surplus Schneider Electric TM3DQ16R relay output module — 16 channels, 2 A per channel, verified condition and…

In Stock

Schneider Electric

BMXDRA0804T

Genuine surplus Schneider Electric BMXDRA0804T: 8-channel relay output module with diagnostics, verified and ready to ship.

In Stock

Schneider Electric

ATV610D15N4

Genuine surplus Schneider Electric ATV610D15N4 drive: 15 kW, 380–460 V three-phase, C3 EMC filter, Modbus RTU. Verified condition,…

In Stock

Schneider Electric

140CRA21220C

Genuine surplus Schneider Electric 140CRA21220C DIO drop interface with two redundant ports — verified condition, ready to ship.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: iC60N 2P C10

We reply within one business day.

iC60N 2P C10 Quote reply within 1 business day