Schneider Electric Circuit Protection
Schneider Electric iC60N 3P C32
Circuit Breaker
Genuine surplus Schneider iC60N 3P C32 breaker — verified 32A C-curve, 6 kA, DIN rail, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated current | 32A |
|---|---|
| Poles | 3P |
| Trip curve | C (thermal-magnetic, magnetic trip 8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated voltage | 400V AC |
| Mounting | 35 mm DIN rail |
| Operating temperature | -35 to 70 °C |
| Dimensions (H×W×D) | 85 × 54 × 78.5 mm |
| Weight | 0.375 kg |
| Standards | EN/IEC 60898-1, EN/IEC 60947-2 |
Description
The Schneider Electric iC60N 3P C32 is a 32 A, three-pole miniature circuit breaker from the Acti9 iC60 range, built for 400 V AC distribution boards on 35 mm DIN rail. Maintenance teams specify it when they need a genuine, verified replacement without waiting on OEM lead times — surplus and refurbished stock gives you a practical route to the exact unit.
What This Breaker Does in Your Panel
The Acti9 iC60N sits in the final distribution layer, protecting three-phase circuits against overload and short circuit. Its C-curve trip characteristic uses thermal-magnetic protection with a magnetic trip at 8×In ±20%, which suits mixed loads where inrush is moderate rather than severe. Rated breaking capacity is 6 kA at 230/400 V under IEC 60898-1, so it covers typical commercial and light industrial sub-distribution where prospective fault current stays within that envelope. The three-pole configuration switches all phases together, which matters for three-phase motors, distribution feeders and equipment isolators. At 85 × 54 × 78.5 mm and 0.375 kg, it occupies three standard DIN modules — plan panel space accordingly before you order.

Technical Specifications That Drive Selection
Three values deserve attention when you match this unit to an existing installation. First, the 32 A rating and C-curve: confirm the downstream cable and load profile align, because a C-curve tolerates brief surges but will not suit high-inrush transformer or capacitor loads without verification. Second, the 6 kA breaking capacity at 230/400 V — check your panel’s prospective fault level; if it exceeds 6 kA, this device is the wrong selection. Third, the operating temperature range of -35 to 70 °C supports demanding enclosure environments, though ambient derating should always be checked against the manufacturer’s data. Mechanical life is 20,000 cycles and electrical life 10,000 cycles, giving a clear basis for planned replacement intervals. Standards compliance covers EN/IEC 60898-1 and EN/IEC 60947-2.
Why Genuine Surplus Makes Sense Here
This model is listed as active in the Acti9 range, last verified 2026-09, so availability is generally good — but OEM lead times still bite when a panel is down. Autronexa holds surplus and refurbished units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a genuine part with a known condition, not a grey-market clone. For a device protecting three-phase circuits, authenticity is not a detail: a copy may not meet the 6 kA rating or the 8×In magnetic trip tolerance. If you are specifying a replacement or stocking a critical spares shelf, contact Autronexa with your part number for verified condition and current availability. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric iC60N 3P C32, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components only — no clones or copies.
What condition will the breaker arrive in?
Our default condition is Refurbished: each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact us for the specific condition grade of current stock.
How fast can you ship the iC60N 3P C32?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus units typically move faster than OEM factory orders.
Does this breaker suit a 400 V three-phase panel?
Yes — it is rated 400 V AC with 6 kA breaking capacity at 230/400 V under IEC 60898-1, and mounts on 35 mm DIN rail. Confirm your prospective fault level does not exceed 6 kA before ordering.
Is the iC60N 3P C32 still in production?
The Acti9 iC60 range is listed as active, last verified 2026-09. Contact Autronexa to confirm OEM support status and current availability for your order.
Related & compatible parts
Schneider Electric
ATV71HD75N4
Genuine surplus Schneider ATV71HD75N4 75 kW drive — verified condition, faster than OEM lead times, with sourcing support…
Schneider Electric
TSXP575634M
Genuine surplus Schneider Electric TSXP575634M Unity processor — verified condition, faster lead times than OEM, and sourcing support…
Schneider Electric
TM3DQ8R
Genuine surplus Schneider TM3DQ8R: 8 relay outputs, 24 V DC, screw terminals. Verified condition, faster than OEM lead…
Schneider Electric
TM3AQ2
Genuine surplus TM3AQ2 analog output module — 2 channels, 12-bit, verified and ready to ship from Autronexa.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…