Schneider Electric PLCs & Controllers
Schneider Electric TSXP575634M
Unity processor
Genuine surplus Schneider Electric TSXP575634M Unity processor — verified condition, faster lead times than OEM, and sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | TSX Micro PLCs |
|---|---|
| Internal RAM | 32 Kwords data and program (without PCMCIA card) |
| PCMCIA Card Capacity | 128 Kwords additional data, 64 Kwords program |
| Execution Time per Instruction | 0.5 µs Boolean without PCMCIA card, 0.6 µs with card |
| Current Consumption | 440 mA at 5 V DC |
| Discrete I/O Capacity | 512 I/O |
| Analogue I/O Capacity | 24 I/O |
| Integrated Connection | Non-isolated serial link, 2 female mini DIN, 19.2 kbit/s |
| Weight | 1.00 lbs (0.45 kg) |
Description
When a TSX Micro PLC processor faults on a running line, every hour of downtime adds cost. The Schneider Electric TSXP575634M Unity processor is the genuine replacement you need — sourced as verified surplus or refurbished stock, so you restore control without waiting on OEM lead times.
What This Processor Brings to a TSX Micro System
The TSXP575634M is a Unity processor for the Modicon Premium automation platform, programmed with Unity Pro software. It ships with 32 Kwords of internal RAM shared between program and data. Adding a PCMCIA card raises data storage by 128 Kwords and program memory by 64 Kwords. Execution runs at 0.5 µs per Boolean instruction without the card and 0.6 µs with it, so scan time stays predictable either way. Local signalling covers four LEDs: green for RUN, red for I/O or configuration fault, red for processor or system fault, and yellow for terminal-port activity. Maintenance technicians can read basic health at a glance without opening the cabinet.

Why Genuine Surplus Fits This Processor
Legacy TSX Micro and Premium platforms still run critical processes, yet OEM lead times for spares can stretch. Autronexa stocks genuine surplus and refurbished units of this processor, each tested against OEM datasheet specifications and functionally verified by our sourcing team. That means you get a part with the correct 32 Kword memory map and 440 mA at 5 V DC current draw, not a lookalike. For maintenance engineers, the practical benefit is a drop-in replacement that avoids rewiring or reconfiguration surprises. Refurbished units arrive cleaned and inspected, with clear lead times quoted before you commit.

Sourcing Checklist Before You Order
Confirm the exact part number and any revision suffix on your existing processor. Check whether your application relies on a PCMCIA card, since the card changes memory and execution figures. Verify rack configuration: this module supports two racks of 12 slots or four racks of 4, 6, or 8 slots. Also confirm the integrated non-isolated serial link (two female mini-DIN ports at 19.2 kbit/s) matches your terminal cabling. Autronexa can cross-reference your current unit against available surplus stock and advise on condition. Please verify current lifecycle status and availability with Autronexa before ordering.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSXP575634M, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished processors, not clones or copies.
What condition will the TSXP575634M arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock.
How fast can you ship the TSXP575634M?
Lead time depends on current stock. Contact Autronexa for a quoted lead time before ordering.
Does this processor work with my existing TSX Micro racks?
The TSXP575634M supports two racks of 12 slots or four racks of 4, 6, or 8 slots. Confirm your rack configuration with Autronexa before purchase.
Is the TSXP575634M still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability.
Related & compatible parts
Schneider Electric
ABE7E16EPN20
Genuine surplus Schneider Electric ABE7E16EPN20 passive discrete I/O sub-base — 16 channels, 24 V DC, verified condition, ready…
Schneider Electric
TSXCANCADD03
Genuine Schneider Electric TSXCANCADD03 CANopen cordset, 0.3 m, molded SUB-D9, IP20. Verified surplus stock ready to ship from…
Schneider Electric
990NAD21930
Genuine surplus Schneider Electric 990NAD21930 Modbus Plus drop cable, 6 m, SUB-D 9 to flying leads — verified…
Schneider Electric
171CCC96020
Genuine surplus Schneider Electric 171CCC96020 processor adapter for Modicon Momentum — verified condition, Ethernet and I/O bus connectivity.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…