Schneider Electric I/O & Function Modules
Schneider Electric TM5ACTB12PS
Terminal Block
Genuine Schneider Electric TM5ACTB12PS 12-pin spring terminal block for Modicon TM5 — verified surplus stock, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Terminal block (accessory) |
|---|---|
| Channels | 12 pins |
| Wiring | Spring-cage terminal, 12-pin |
| Operating temperature | 0...+55 °C |
| Storage temperature | -25...+70 °C |
| Protection rating | IP20 |
| Compatible platforms | Modicon M241, M251, M258, LMC058 |
| Lifecycle | Active (Last verified: 2026-09) |
Description
The Schneider Electric TM5ACTB12PS is a 12-pin spring-cage terminal block for Modicon TM5 I/O modules, and maintenance teams turn to genuine surplus stock when a wiring point fails mid-shift and the OEM channel cannot deliver quickly. This accessory is a passive part, so its reliability depends on the spring contacts and housing rather than electronics, which makes verified condition the deciding factor.
What This Terminal Block Does in a TM5 System
The TM5ACTB12PS is a field-wiring interface, not an active module. It seats onto a TM5 I/O slice and gives each of its 12 pins a spring-cage termination point, so technicians can land sensor and actuator conductors without screw terminals. Because the block is passive, it carries no supply voltage, bus current, or diagnostics of its own — the host module handles all signal processing. In practice, this means a failed terminal block rarely shows up as a module fault; it appears as an intermittent connection, a loose conductor, or a pin that no longer grips. Keeping a spare on the shelf shortens the repair window considerably. The part is rated for 0…+55 °C operation and -25…+70 °C storage, with an IP20 protection rating suited to cabinet-interior mounting.

Compatibility Across the Modicon Range
The terminal block is listed as compatible with Modicon M241, M251, M258, and LMC058 platforms, where it serves as the terminal accessory for TM5 modules. Before ordering, confirm the host slice model and revision, because terminal accessories are matched to specific module widths and pin counts. The 12-pin spring-cage layout must align with the module’s terminal assignment; a block from a different slice will not seat correctly. If your installation mixes TM5 slices across these controllers, note the exact module reference alongside the terminal block part number when you request a quote, and our sourcing team will cross-check the pairing against the datasheet.

Why Genuine Surplus Fits This Part
Terminal blocks are high-wear accessories: they are removed during module swaps, re-terminated during panel modifications, and stressed by repeated conductor insertion. A refurbished unit that has been inspected for spring tension and housing integrity is a practical alternative to waiting on a factory order. Autronexa supplies genuine surplus and refurbished components, with each unit checked against OEM datasheet specifications and functionally verified before dispatch. The lifecycle status is active, last verified in September 2026, so the part remains a current platform accessory rather than an obsolete item. That said, please verify current lifecycle status and availability with Autronexa before ordering, since stock levels on accessories move quickly. For maintenance planners, holding one or two verified spares removes the terminal block from the critical-path list during a module replacement.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TM5ACTB12PS, or a compatible copy?
Autronexa supplies genuine Schneider Electric units. Each terminal block is checked against OEM datasheet markings and the part-number cross-reference before it is listed, so the 12-pin spring-cage configuration matches the original specification.
What condition will the terminal block arrive in?
Units ship in refurbished condition as the site default. Each block is inspected for spring-cage tension and housing integrity, then functionally verified by our sourcing team before dispatch.
How fast can you ship the TM5ACTB12PS?
Lead time depends on current stock. Contact Autronexa for the present lead time and availability; surplus and refurbished units are typically ready to ship once verified.
Does this terminal block work with Modicon M241 and M251 controllers?
The datasheet lists compatibility with Modicon M241, M251, M258, and LMC058 platforms as a TM5 module terminal accessory. Confirm your host slice model and revision before ordering.
Is the TM5ACTB12PS still supported by Schneider Electric?
Lifecycle status is listed as active, last verified in September 2026. Contact Autronexa to confirm current OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
ATV610U07N4
Genuine surplus Schneider ATV610U07N4 drive, 0.75 kW, 380...460 V, with C3 EMC filter — verified condition and practical…
Schneider Electric
490NAA27101
Genuine surplus Schneider Electric 490NAA27101 Modbus Plus trunk cable, 1 m — verified condition, ready to ship from…
Schneider Electric
BMENOS0300
Genuine surplus BMENOS0300 switch module for Modicon X80 — verified condition, faster lead times than OEM.
Schneider Electric
TSXCDP203
Genuine surplus Schneider Electric TSXCDP203 2m HE10 connecting cable for Modicon PLCs — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
