Technical specifications
| Rated motor power | 0.75 kW (1 HP) normal duty; 0.37 kW (0.5 HP) heavy duty |
|---|---|
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 2.2 A (normal duty) |
| Maximum input current | 3.1 A at 380 V, 2.6 A at 460 V (normal duty) |
| Integrated EMC filter | Category C3 |
| Integrated HMI | Plain text display terminal VW3A1113 (2 lines, white backlit LCD, RJ45) |
| Digital inputs | 6, 24 V DC (2 programmable as pulse inputs) |
| Analog inputs | 3, software-configurable 0...10 V / 0...20 mA |
| Operating temperature | -15...+45 °C without derating; up to +60 °C with power derating |
| Dimensions (H×W×D) | 297 × 145 × 203 mm |
Description
When a pump or fan drive drops out on a live process, every hour of downtime adds cost. The Schneider Electric ATV610U07N4 is a 0.75 kW (1 HP) normal-duty variable speed drive from the Easy Altivar 610 series, built for 380…460 V three-phase supply with an integrated C3 EMC filter and plain text display terminal. For maintenance and procurement teams, a genuine surplus or refurbished unit is often the fastest route back to running condition without paying full OEM list price.
What This Drive Does in a Pump or Fan Circuit
The unit is an AC frequency inverter for three-phase asynchronous and synchronous motors in open loop. Its quadratic U/f control profile (UFQ) suits variable-torque loads such as centrifugal pumps and fans, while standard and 5-point U/f curves cover constant-torque duties. The integrated plain text display terminal VW3A1113 gives two lines of white backlit LCD over RJ45, so commissioning and fault reading happen at the enclosure without a laptop. A Category C3 EMC filter is built in, which simplifies panel design where that emission class is acceptable. The drive ships in frame size 1 at 297 × 145 × 203 mm and 3.135 kg, and its fan is field-replaceable in under five minutes without special tools — a practical point when a cooling fan is the only worn item after years of service.

Electrical and I/O Fit for Retrofit Work
On the electrical side, maximum input current is 3.1 A at 380 V and 2.6 A at 460 V, with 2.2 A maximum continuous output current in normal duty and 2.4 A transient for 60 s. Heavy duty is rated 0.37 kW at 1.5 A continuous. The drive accepts 2…12 kHz switching frequency with 4 kHz nominal, and motor cable runs up to 100 m shielded or 150 m unshielded without a dv/dt filter, with an output filter recommended above 50 m. Control connectivity includes 3 analog inputs configurable 0…10 V or 0…20 mA, 6 digital inputs at 24 V DC (two programmable as pulse inputs), 2 analog outputs and 3 relay outputs. Two RJ45 ports are provided — one Modbus field network, one HMI multidrop — and Slot A accepts an Extended I/O module VW3A3203, Extended relay module VW3A3204 or PROFIBUS DP V1 module VW3A3607. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier.

Why Genuine Surplus Makes Sense Here
Autronexa supplies genuine surplus and refurbished automation components, and this series is one we handle regularly. A refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team, so you know the input current, output rating and I/O behaviour match the published data before it ships. Compared with waiting on an OEM factory lead time, surplus stock often shortens the path back to production, and the cost saving versus OEM list price is meaningful on a frame size 1 drive. Before ordering, confirm the exact model and any revision notes, decide whether surplus or refurbished condition fits your spares policy, and check accessory compatibility for Slot A modules you intend to reuse. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this ATV610U07N4 a genuine Schneider Electric drive, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. The drive is supplied as genuine surplus or refurbished Schneider Electric equipment, not a copy.
What condition will the drive arrive in?
The site default condition is Refurbished. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need surplus condition instead.
How fast can you ship this drive?
Lead time depends on current stock. Contact Autronexa for current lead time and availability before placing your order.
Does this drive support Modbus and PROFIBUS DP?
Yes. Two RJ45 ports provide a Modbus field network and HMI multidrop link, and Slot A accepts the PROFIBUS DP V1 module VW3A3607. Confirm cabling and gateway requirements with your supplier.
Is the Easy Altivar 610 line still supported by Schneider Electric?
Official product pages for the Easy Altivar 610 line were active as of 2026-10. Contact Autronexa to verify current OEM support status for your specific unit.
Related & compatible parts
Schneider Electric
140AII33000C
Genuine surplus Schneider Electric 140AII33000C input module — verified, tested against OEM specs, and ready to ship from…
Schneider Electric
ATV610D75N4
Genuine surplus Schneider ATV610D75N4 75 kW drive, verified and ready to ship from Autronexa.
Schneider Electric
TM2AMM6HT
Genuine surplus TM2AMM6HT analog I/O module for Modicon M238 — 4 current/voltage inputs, 2 outputs, verified and ready…
Schneider Electric
140DAI74000
Genuine surplus Schneider Electric 140DAI74000: 16-channel 230 V AC discrete input module for Modicon Quantum, verified and ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…