Schneider Electric I/O & Function Modules
Schneider Electric TM2AMM6HT
Input/output analog module
Genuine surplus TM2AMM6HT analog I/O module for Modicon M238 — 4 current/voltage inputs, 2 outputs, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Analogue input number | 4 |
|---|---|
| Analogue output number | 2 |
| Input type | Current 4...20 mA non differential; Voltage 0...10 V non differential |
| Output type | Current 4...20 mA; Voltage 0...10 V |
| Resolution | 12 bits input and output |
| Supply voltage | 24 V DC (limits 19.2...30 V) |
| Current consumption | 60 mA at 5 V DC internal; 80 mA at 24 V DC external |
| Dimensions | 0.93 in (23.5 mm) W x 2.76 in (70 mm) D x 3.54 in (90 mm) H |
| Product weight | 0.19 lb(US) (0.085 kg) |
Description
When an analog I/O module fails on a running Modicon M238 line, every hour of downtime adds cost. The TM2AMM6HT from Schneider Electric is a 4-input, 2-output analog module built for current and voltage signals, and sourcing a genuine surplus unit keeps that line moving without OEM lead-time delays.
What This Module Does in a Modicon M238 System
The TM2AMM6HT handles high-level analog signals where precise measurement matters. It provides four non-differential inputs configurable for 4…20 mA current or 0…10 V voltage, plus two analog outputs on the same signal ranges. Both input and output resolution is 12 bits, with an LSB value of 2.5 mV for voltage and 4 µA for current. The module uses a shielded cable and photocoupler insulation between channel and internal logic, which helps isolate field wiring from the controller backplane. A removable screw terminal block simplifies field wiring and replacement during maintenance. The unit draws 60 mA at 5 V DC internally and 80 mA at 24 V DC from an external supply, with a rated supply of 24 V DC and limits of 19.2…30 V.

Technical Specs That Matter on the Floor
The 12-bit resolution on both inputs and outputs gives maintenance teams enough granularity for most process-control loops without external signal conditioners. Measurement error is +/- 0.5 % of full scale at 25 °C for both 0…10 V and 4…20 mA ranges, and the temperature coefficient is +/- 0.02 %FS/°C, so accuracy holds across normal panel temperature swings. Conversion time is 20 ms plus one controller cycle, and sampling duration is <= 16 ms, which is adequate for monitoring and control tasks that do not demand high-speed acquisition. The module tolerates a permissible continuous overload of 13 V or 40 mA, giving some headroom against field transients. For load matching, the current output supports ohmic loads = 2000 Ohm. Input impedance is = 1 Ohm for voltage.

Surplus Advantage: Verified and Ready to Ship
Autronexa supplies this module as genuine surplus and refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. For maintenance engineers, that means a replacement that matches the original part number and form factor without waiting on OEM allocation. The module weighs 0.19 lb (0.085 kg) and measures 0.93 in wide, 2.76 in deep, and 3.54 in high, so it fits the same panel space as the original. Because analog modules are often the first component pulled when a controller is decommissioned, surplus supply can be more consistent than new-production channels for older Modicon M238 installations. Each unit is inspected for terminal-block integrity and channel function before dispatch. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TM2AMM6HT, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the module arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade.
How fast can you ship the TM2AMM6HT?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability.
Does this module work with Modicon M238 and Advantys OTB?
The datasheet lists range compatibility with Modicon M238 logic controller, Advantys OTB, and Twido. Confirm your exact controller revision with Autronexa before ordering.
Is the TM2AMM6HT still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability.
Related & compatible parts
Schneider Electric
BMXDDI1603
Genuine surplus Schneider Electric BMXDDI1603 Modicon X80 16-channel discrete input module, verified and ready to ship.
Schneider Electric
TSXP571634
Genuine surplus Schneider Electric TSXP571634 Unity Processor — verified, refurbished, with 512 discrete and 24 analogue I/O capacity.
Schneider Electric
BMXP342030
Genuine surplus BMXP342030 Modicon M340 CPU — ARM9, CANopen + Ethernet, verified condition, faster than OEM lead time.
Schneider Electric
iC60H 2P C20
Genuine surplus iC60H 2P C20 from Schneider Electric: 20A C-curve, 10 kA breaking capacity, verified condition and clear…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…