Technical specifications
| Module type | Digital input (sink) |
|---|---|
| Channels | 16 |
| Signal type | 24 Vdc, sink (Type 1 per IEC 61131-2) |
| Input range | 24 Vdc nominal, 19.2-28.8 Vdc |
| Input current | 3.75 mA per channel (at 24 Vdc) |
| Response time | ≤3 ms (configurable input filter) |
| Power consumption | 2.5 W |
| Operating temperature | 0...+55 °C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 99 × 12.5 × 75 mm |
Description
When a Modicon TM5 slice fails on a running machine, every hour of downtime adds cost. The Schneider Electric TM5SDI16D is a 16-channel, 24 Vdc digital input module for the TM5 distributed I/O platform, and sourcing a genuine surplus or refurbished unit is often the fastest way to restore input capacity without paying full OEM list price. Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Module Does in a TM5 System
The TM5SDI16D is a digital input (sink) slice rated for 24 Vdc signals, Type 1 per IEC 61131-2, with an operating range of 19.2-28.8 Vdc. It draws 3.75 mA per channel at 24 Vdc, so sixteen active inputs add a modest load to the field supply — useful when you are sizing a shared 24 Vdc rail across several slices. The module reports ModuleOK, DcOk, and NetworkOk diagnostics, which lets maintenance staff distinguish a field-wiring fault from a bus or supply problem without swapping cards. A configurable input filter with response time ≤3 ms helps reject contact bounce on mechanical sensors while keeping scan response predictable. At 2.5 W power consumption and 45 mA on the 5 V DC TM5 bus, it adds little heat and bus load to a crowded rack.

Why Genuine Surplus Fits This Module
Because the TM5 platform remains active, buyers often default to a new OEM order — but OEM lead times can stretch when a single slice is backordered, and a full list-price purchase is hard to justify for a spare. Genuine surplus and refurbished unit units give maintenance teams a practical middle path: tested against OEM datasheet specifications and functionally verified by our sourcing team, at a cost below OEM list. For a module with no isolation between channels and 500 Vrms AC isolation between channel and bus, condition matters — a refurbished unit that has been checked for channel-to-bus integrity is a safer bet than an untested pull. Autronexa stocks these as genuine parts, verified, so you know what arrives.

Sourcing Checklist Before You Order
Confirm the exact model and any revision marking on your existing slice, since This unit is one configuration within the Modicon TM5 family. Check that your controller platform is listed as compatible — Modicon M241, M251, M258, or LMC058 — and that your field devices are 24 Vdc sink outputs. Decide whether you need a surplus unit or a refurbished one; both are genuine, but condition grading differs. The module measures 99 × 12.5 × 75 mm and weighs 0.025 kg, so it fits standard TM5 slice spacing. Operating temperature is 0…+55 °C and protection rating is IP20, which suits cabinet-mounted installations. Please verify current lifecycle status and availability with Autronexa before ordering, and contact us with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TM5SDI16D, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the TM5SDI16D arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — confirm the condition you need when you request a quote.
How fast can you ship the TM5SDI16D?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we will confirm the ship date before you order.
Will this module work with my Modicon controller?
The TM5SDI16D is listed as compatible with Modicon M241, M251, M258, and LMC058 platforms. Confirm your controller model and that your field devices are 24 Vdc sink outputs before ordering.
Related & compatible parts
Schneider Electric
140CPU21304C
Genuine surplus Schneider 140CPU21304C Modicon Quantum CPU — conformal coated, 768 KB RAM, verified and ready to ship.
Schneider Electric
140ERT85420
Genuine surplus Schneider Electric 140ERT85420 multifunction input module — 32 inputs, 40 terminals, optocoupler insulation, verified and ready…
Schneider Electric
140CPU67261
Genuine surplus Schneider Electric 140CPU67261 Unity Processor — verified, tested, and ready to ship for Modicon Quantum systems.
Schneider Electric
170BAI03600
Genuine surplus Schneider Electric 170BAI03600 analog input module — 8 channels, 24 V DC, verified condition and ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…