Schneider Electric PLCs & Controllers
Schneider Electric TSX17-ACC1
Backup power module
Genuine surplus Schneider Electric TSX17-ACC1 backup power module for TSX Micro PLCs — verified 3.6 V DC, 1200 mAh lithium cell.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | TSX Micro PLCs |
|---|---|
| Nominal Voltage | 3.6 volts DC output |
| Energy Storage Capacity | 1200 milliampere-hours (mAh) |
| Electrochemical Composition | Lithium-based primary cell chemistry (non-rechargeable) |
| Maximum Discharge Current | 100 milliamperes (0.1 A) continuous load capacity |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -60°C to +85°C |
| Shelf Life | Up to 10 years at 20°C |
| Weight | 0.06 lbs (0.03 kg) |
| Safety Certifications | Compliant with IEC 60086 and UL 1642 standards |
Description
The Schneider Electric TSX17-ACC1 is a backup power module for the TSX Micro PLCs series, rated at a nominal 3.6 volts DC with 1200 mAh energy storage. Maintenance and procurement teams choose genuine surplus units like this one to keep PLC memory supported without waiting on OEM lead times or paying full list price.
What This Module Does in a TSX Micro System
The module is a non-rechargeable lithium-based primary cell that holds low-current backup duty inside the TSX Micro PLCs family. Its 1200 mAh capacity and flat discharge curve suit the steady, low-draw load of PLC backup applications, where a stable voltage matters more than peak current. Continuous load capacity is 100 milliamperes, so it is intended for sustaining backup circuits rather than powering active I/O. The cell weighs 0.06 lbs (0.03 kg), which keeps handling and replacement straightforward during routine service. Because the chemistry is non-rechargeable, the unit is a consumable-style backup component rather than a rechargeable battery. Please verify current lifecycle status and availability with Autronexa before ordering.

How It Compares With Other Backup Options
Buyers often weigh this module against rechargeable battery packs and generic coin-cell substitutes. The table below sets out the practical differences based on the published data for this unit.
| Option | Chemistry | Nominal Output | Backup Suitability |
|---|---|---|---|
| TSX17-ACC1 (this module) | Lithium-based primary, non-rechargeable | 3.6 volts DC | Flat voltage curve for low-current PLC backup |
| Rechargeable battery pack | Rechargeable chemistry | Varies by pack | Requires charging circuitry; not a drop-in for this cell |
| Generic coin cell | Often unspecified | Often unspecified | No published IEC 60086 / UL 1642 compliance |
This unit is stated as compliant with IEC 60086 and UL 1642 standards, which is a useful checkpoint when comparing against unbranded alternatives. The operating range of -40°C to +85°C and storage range of -60°C to +85°C also give maintenance planners clear environmental limits for cabinet and stores conditions.

Surplus Advantage and Sourcing Checks
Genuine surplus and refurbished stock makes practical sense for a backup module with a published shelf life of up to 10 years at 20°C. Autronexa verifies units against OEM datasheet markings and part-number cross-reference, so you know the module you receive is the genuine article rather than a lookalike. Before ordering, confirm the exact model match for your TSX Micro PLCs installation, check whether you need surplus or refurbished condition, and ask for the current lead time. Our sourcing team works with Allen-Bradley, Bently Nevada, Siemens and Schneider systems daily and can help you confirm fit. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSX17-ACC1, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed, so you receive a genuine Schneider Electric module rather than a copy.
What condition will the TSX17-ACC1 arrive in?
Our default condition is refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition you need when you enquire.
How fast can you ship the TSX17-ACC1?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm verified condition and the current lead time before you order.
What is the shelf life of this backup module?
The published shelf life is up to 10 years at 20°C, with a storage temperature range of -60°C to +85°C. Store units within those limits to preserve backup performance.
Is the TSX17-ACC1 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
TSX3721001
Genuine surplus Schneider Electric TSX3721001 modular base controller — verified condition, tested, and ready to ship from Autronexa.
Schneider Electric
140XBP01600
Genuine surplus Schneider Electric 140XBP01600 16-slot Modicon Quantum backplane rack — verified condition, panel mount, ready to ship.
Schneider Electric
BMXSRA0405
Genuine surplus Schneider Electric BMXSRA0405 Modicon X80 safety relay output module — 4 isolated outputs, verified condition, ready…
Schneider Electric
BMEH582040S
Genuine surplus Schneider BMEH582040S SIL3 Hot Standby CPU — verified condition, faster than OEM lead time, sourcing help…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…