Technical specifications
| Product Line | Modicon |
|---|---|
| Power Supply Voltage | 110 to 240 Volts AC |
| Number of Inputs/Outputs | 24 inputs/outputs |
| Input Type | 24 Volts DC input |
| Output Type | Relay output |
| Status Indicator Type | 5 LED indicators |
| Supply Frequency | 50 to 60 Hertz |
| Ambient Operating Temperature | 5 to 55°C (non-condensing) |
| Weight | 2.63 lbs (1.19 kg) |
Description
How do you keep a Modicon-based control cabinet running when the OEM lead time stretches into weeks? The Schneider Electric TSX1702028 programmable controller is the answer for maintenance teams that need a verified, genuine replacement without waiting on a factory backlog. This 24 I/O unit runs on 110 to 240 Volts AC and pairs 24 Volts DC inputs with relay outputs, so it slots into existing automation panels with minimal rework. Autronexa stocks genuine surplus and refurbished units, each checked against OEM datasheet markings before it ships.
What This Modicon Controller Does in a Panel
The TSX1702028 sits in Schneider Electric’s Modicon product line and handles the core logic and switching duties of a compact control system. Its 24 input/output points split into 24 Volts DC inputs and relay outputs — a combination that lets the controller read sensor and switch signals while directly driving contactors, solenoids, and indicator circuits without extra interposing relays. Five LED status indicators give technicians a fast visual read on operating state during troubleshooting. The unit accepts a supply frequency of 50 to 60 Hertz with a frequency limit of 47 to 63 Hertz, and it tolerates supply voltage fluctuation from 96 to 264 Volts AC, which matters in plants where line voltage drifts. At 2.63 lbs (1.19 kg), it is manageable for one-person installation.

Why Genuine Surplus Fits This Controller
Programmable controllers in the Modicon family are often retired from service long before the surrounding panel is upgraded, which puts steady demand on the surplus market. That is where Autronexa’s model works in your favor: refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so you know the 24 Volts DC input thresholds and relay output behavior meet the original published values before the part reaches your dock. Compared with an OEM list price or an open-ended factory lead time, a verified surplus unit keeps spares budgets predictable and gets the panel back online sooner. Genuine parts, verified — not grey-market substitutes.

Sourcing Checklist Before You Order
Match the exact model and confirm your panel’s I/O count and signal types align with the 24-point, 24 Volts DC input, relay output configuration described here. Check the environmental envelope: the controller is rated for 5 to 55°C ambient operating temperature and -25 to 70°C storage, both in non-condensing conditions, with humidity tolerance of 30% to 95% relative humidity without condensation. Decide whether surplus or refurbished condition suits your application, and confirm any accessory or terminal compatibility with your supplier. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this TSX1702028 a genuine Schneider Electric unit or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before listing. The controller you receive is a genuine Schneider Electric Modicon part, not a copy or grey-market substitute.
What condition will the TSX1702028 arrive in?
Our default condition is Refurbished — tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available; confirm the condition you need when you request a quote.
How fast can Autronexa ship the TSX1702028?
Contact Autronexa for current lead time. Stocked surplus and refurbished units are ready to ship once condition and availability are confirmed for your order.
Does the TSX1702028 support 24 Volts DC inputs and relay outputs together?
Yes. The published configuration lists 24 total input/output points with 24 Volts DC inputs and relay outputs, plus five LED status indicators for operational feedback.
Is the TSX1702028 still supported by Schneider Electric?
Lifecycle status is not stated in our available data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
Schneider Electric
140CPU65860
Genuine surplus Schneider Electric 140CPU65860 Unity processor for Modicon Quantum — verified condition, practical lead times, and sourcing…
Schneider Electric
490NAC0100
Genuine surplus Schneider 490NAC0100 hot standby copper adapter for Modicon M580 redundant processors — verified condition, ready to…
Schneider Electric
TSXPSY1610M
Genuine surplus Schneider Electric TSXPSY1610M power supply for TSX Micro PLCs — verified, tested, and ready to ship…
Schneider Electric
140XBP01600
Genuine surplus Schneider Electric 140XBP01600 16-slot Modicon Quantum backplane rack — verified condition, panel mount, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…