Schneider Electric PLCs & Controllers
Schneider Electric TSX1722028
PLC Module
Genuine surplus Schneider Electric TSX1722028 PLC module — 10 inputs/10 outputs, 120/240 VAC, panel mount. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Product Line | Modicon |
|---|---|
| Input Voltage | 120/240 VAC |
| Current Rating (Input) | 0.5/0.25 AMP |
| I/O Type | 10 Inputs / 10 Outputs |
| Output Type | Digital (Discrete) |
| Relay Type | Relays |
| Signal Voltage | 24V DC for I/O |
| Mounting Type | Panel Mount |
| Temperature Range | -10°C to +60°C |
| Weight | 3.44 lbs (1.56 kg) |
Description
When a digital control loop stalls on a running line, every hour of downtime adds cost. The Schneider Electric TSX1722028 PLC module — a Modicon-series, panel-mount unit with 10 inputs and 10 outputs — is the kind of genuine surplus part Autronexa stocks to get that loop back online without waiting on OEM lead times.
What This Modicon Module Does in a Control Cabinet
The TSX1722028 is an AC-powered, standalone PLC module built for discrete control. It accepts 120/240 VAC at 0.5/0.25 AMP and switches relay outputs, so it can drive contactors, solenoids, and indicator circuits directly without an intermediate interface relay — a real saving in panel space and wiring cost. Its I/O signal voltage is 24V DC, and the 10-in/10-out count covers small-to-mid control tasks where a full rack PLC would be over-specified. Because it has no communication interface, it runs independently: no network gateway, no protocol licence, no firmware dependency to manage. That standalone design lowers integration cost and removes a common failure point in legacy cabinets. The unit weighs 3.44 lbs (1.56 kg) and panel-mounts directly.

Why Genuine Surplus Fits This Module
Modicon-series discrete modules like this one are frequently requested by maintenance teams keeping existing panels running. Buying new from the OEM channel can mean extended lead time and full list price for a part that is often available as verified surplus. Autronexa sources genuine units and has them tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch — so you get a part you can trust at a fraction of the new-part cost. For a standalone module with no firmware or network configuration to re-establish, a verified refurbished unit is a practical drop-in replacement: swap it, re-terminate the existing wiring, and the control logic continues unchanged. That is genuine parts, verified — and surplus and refurbished, ready to ship.

Sourcing Checklist Before You Order
Confirm three things before committing. First, match the exact model and revision: This unit is a specific Modicon configuration, and mixing it with a different I/O count or voltage variant will not fit your panel. Second, confirm the operating environment: the module is rated for -10°C to +60°C, so verify your cabinet stays inside that band, since overheating is a leading cause of repeat failures and unplanned cost. Third, decide condition: surplus, refurbished, or new — each carries a different price and lead-time trade-off. Ask for the condition grade in writing. Autronexa can cross-reference the part number against OEM markings and confirm accessory and terminal compatibility before you buy. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this a genuine Schneider Electric TSX1722028, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the TSX1722028 arrive in?
Our default condition is Refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific condition grade on the unit reserved for you.
How fast can you ship this PLC module?
Contact Autronexa with your part number for current lead time and availability. Surplus and refurbished stock is ready to ship once condition is confirmed.
Does the TSX1722028 need a communication network to operate?
No. This module is a standalone unit with no communication interface, so it runs independently of any fieldbus or network — which simplifies installation and reduces integration cost.
Is the TSX1722028 still supported by Schneider Electric?
Contact Autronexa to verify current OEM support and lifecycle status. We can confirm what is available from surplus and refurbished stock either way.
Related & compatible parts
Schneider Electric
140NOE25110C
Genuine surplus Schneider Electric 140NOE25110C TCP/IP module for Modicon Quantum — 8 channels, fiber support, verified condition.
Schneider Electric
140CPS21400C
Genuine surplus Schneider Electric 140CPS21400C power supply for Modicon Quantum — verified condition, tested, ready to ship.
Schneider Electric
iC60N 2P C63
Genuine Schneider Electric iC60N 2P C63 miniature circuit breaker — verified surplus/refurbished stock with clear lead times from…
Schneider Electric
TM2DDI8DT
Genuine surplus Schneider Electric TM2DDI8DT discrete input module — 8 inputs, 24 V DC, verified condition, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
