Schneider Electric I/O & Function Modules
Schneider Electric TSXAEY1614
Analog input module
Genuine surplus Schneider TSXAEY1614 analog input module — 16 thermocouple/voltage channels, verified condition, faster than OEM lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Analog Input Channels | 16 high-level inputs |
|---|---|
| Analog/Digital Conversion | 16 bits |
| Input Types | Thermocouple (B, E, J, K, L, N, R, S, T, U), Voltage (+/- 80 mV) |
| Nominal Read Cycle Time | 70 ms per channel |
| Isolation | 1000 Vrms between channels and bus; 1000 Vrms between channels and ground |
| Common Mode Voltage | 250 V AC or 280 V AC between channels; 250 V DC between channels and earth |
| Electrical Connection | 2 connectors SUB-D 25 |
| Current Consumption | 300 mA at 5 V DC |
| Operating Temperature | 0 to 60°C |
| IP Degree of Protection | IP20 |
Description
The Schneider Electric TSXAEY1614 is a 16-channel analog input module for TSX Micro PLCs, built to read thermocouple and low-level voltage signals in process monitoring. For maintenance teams replacing a failed unit, genuine surplus stock from Autronexa offers a verified, practical alternative to waiting on OEM lead times.
What This Module Does in a TSX Micro Rack
The TSXAEY1614 occupies a standard module slot and accepts 16 high-level inputs through two SUB-D 25 connectors. It converts each channel with 16-bit resolution and a nominal read cycle time of 70 ms per channel, so a full scan of all inputs completes in roughly 1.1 seconds. That pace suits temperature and millivolt monitoring loops rather than high-speed control.
The input stage handles thermocouple types B, E, J, K, L, N, R, S, T and U, plus voltage at +/- 80 mV. Measurement error depends on the thermocouple selected: 0.8°C for type E at 25°C, rising to 4°C for type B across 0…60°C. Isolation is rated 1000 Vrms between channels and bus and between channels and ground, which matters when sensors sit at different ground potentials. Common mode tolerance reaches 250 V AC or 280 V AC between channels and 250 V DC between channels and earth.

Why Buy This Module as Surplus
TSX Micro hardware is mature, and replacement demand comes from plants keeping existing racks running rather than from new installations. That is exactly where surplus and refurbished stock earns its place. Autronexa sources genuine units and verifies them against OEM datasheet markings and part-number cross-reference before they ship, so you know the module matches the original specification.
Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team. You avoid OEM list pricing and the lead time that comes with ordering legacy automation parts through standard channels. The module carries CE marking and marine certifications including DNV, ABS and LR, and operates from 0 to 60°C at 10 to 95% relative humidity without condensation.

Buyer’s Checklist Before You Order
Confirm your rack is a TSX Micro or Modicon Premium platform, since this module belongs to that family. Check the thermocouple type used at each input against the supported list, and verify your field wiring terminates in the two SUB-D 25 connectors. Note that input overvoltage protection is specified as -15…15 V at state 0 and -30…30 V at state 1, with overcurrent rated -30…30 mA at state 1.
Ask your supplier to confirm condition grading, whether the unit is surplus or refurbished, and the exact revision on the label. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this TSXAEY1614 a genuine Schneider Electric module or a copy?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it ships. We supply genuine surplus and refurbished modules, not clones or grey-market copies.
What condition will the module arrive in?
Units ship in refurbished condition by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the specific grading on the unit currently in stock.
How fast can you ship the TSXAEY1614?
Lead time depends on current stock. Contact Autronexa with your part number and we will confirm availability and the shipping window for your order.
Which thermocouple types does this module accept?
It supports thermocouple types B, E, J, K, L, N, R, S, T and U, plus voltage input at +/- 80 mV, across 16 channels with 16-bit conversion.
Is the TSXAEY1614 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status, and confirm current availability before ordering.
Related & compatible parts
Schneider Electric
BMENUA0100
Genuine surplus Schneider Electric BMENUA0100 serial module for Modicon M580 — verified condition, practical lead times, and sourcing…
Schneider Electric · Advantys STB
STBDDI3420
Genuine surplus Schneider Electric STBDDI3420 digital input module — 4 sink channels, hot-swappable, verified condition and clear lead…
Schneider Electric
140CPU65160
Genuine surplus Schneider 140CPU65160 Unity processor for Modicon Quantum — verified condition, practical lead times, sourcing support from…
Schneider Electric
TSXP57453M
Genuine surplus Schneider TSXP57453M PL7 processor — verified condition, 16-rack support, up to 2040 discrete I/O, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
