Schneider Electric I/O & Function Modules

Schneider Electric TSXAEY414

Analog input module

Manufacturer: Schneider Electric Part Number: TSXAEY414

Genuine surplus Schneider Electric TSXAEY414 analog input module — verified condition, faster lead times than OEM, and expert sourcing support.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Analog Input Channels 4 high-level inputs
Input Types Current (4-20 mA), Voltage (±10 V, 0-10 V, 0-5 V, 1-5 V), Thermocouple (B, E, J, K, L, N, R, S, T, U), Resistor (0-400 Ohm, 0-3850 Ohm), Temperature probe (Pt 100, Pt 1000, Ni 1000)
Analog/Digital Conversion 16 bits
Nominal Read Cycle Time 550 ms
Isolation 2830 Vrms between channels and bus, 1780 Vrms between channels and ground
Common Mode Voltage 415 V AC or 200 V DC between channels, 240 V AC or 110 V DC between channels and earth
Operating Temperature 0 to 60°C
Current Consumption 660 mA at 5 V DC
Electrical Connection Screw terminal block

Description

When a TSX Micro PLC rack loses an analog input card, every hour of downtime adds cost. The Schneider Electric TSXAEY414 is a 4-channel analog input module for TSX Micro PLCs, and sourcing a genuine surplus or refurbished unit from Autronexa keeps your line running without OEM lead times or list-price premiums.

What the TSXAEY414 Does in a TSX Micro PLC

This unit accepts four high-level analog inputs and converts them to 16-bit digital values for the PLC. It handles current (4-20 mA), voltage (±10 V, 0-10 V, 0-5 V, 1-5 V), thermocouple types B, E, J, K, L, N, R, S, T, U, resistor (0-400 Ohm, 0-3850 Ohm), and temperature probes (Pt 100, Pt 1000, Ni 1000). That flexibility means one module type covers many measurement points, reducing spare-parts inventory cost. The nominal read cycle time is 550 ms, and the screw terminal block simplifies field wiring. Measurement error varies by input type — for example, 0.13% of full scale for 0-400 Ohm at 25°C — so you can match the module to the accuracy your process needs without overpaying for unused precision.

Figure 1: Front view of the Schneider Electric TSXAEY414 Analog input module showing its physical design and enclosure.

Surplus Advantage: Why Refurbished Makes Sense Here

New-from-OEM TSX Micro modules carry long lead times and premium pricing. Autronexa stocks genuine surplus and refurbished unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. You get the same form, fit, and function at a fraction of the OEM list price, with faster availability. The module’s 2830 Vrms isolation between channels and bus and 1780 Vrms between channels and ground are verified on every unit we ship. For maintenance teams managing legacy TSX Micro systems, this is a practical way to extend asset life without compromising reliability. Contact Autronexa with your part number for verified condition and current availability.

Figure 2: Technical layout and connection details for the Schneider Electric TSXAEY414 Analog input module.

Selection & Sourcing Guide

Before ordering a unit, confirm your rack accepts the standard module format and that your input types match the module’s range. Check the electrical connection — this unit uses a screw terminal block. Verify the operating temperature range (0 to 60°C) suits your panel environment, and note the 660 mA current consumption at 5 V DC when budgeting power. Autronexa provides genuine parts, verified, with clear condition notes and lead times. Please verify current lifecycle status and availability with Autronexa before ordering.

📄 Download Datasheet: TSXAEY414-datasheet.pdf

Frequently asked questions

Is this a genuine Schneider Electric TSXAEY414, or a clone?

Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished modules, not grey-market copies.

What condition will the TSXAEY414 arrive in?

Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us for current stock and condition details.

How fast can you ship the TSXAEY414?

Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus and refurbished units are often ready to ship faster than OEM factory orders.

Does the TSXAEY414 work with my existing TSX Micro PLC rack?

The module is designed for TSX Micro PLCs and uses a standard module format with a screw terminal block. Confirm your rack model and input requirements with our team before ordering.

Is the TSXAEY414 still supported by Schneider Electric?

Lifecycle status varies. Contact Autronexa to verify OEM support status and current availability before ordering.

Related & compatible parts

Schneider Electric

SR2B201FU

Genuine surplus Schneider Electric SR2B201FU Zelio Logic smart relay, 20 I/O, 100-240V AC — verified condition and clear…

In Stock

Schneider Electric

170ADM37012

Genuine surplus Schneider 170ADM37012 mixed I/O module — 16 DI, 8 DO, 4 AI, 2 AO. Verified condition,…

In Stock

Schneider Electric

ATV610D45N4Z

Genuine surplus Schneider ATV610D45N4Z, 45 kW pump/fan drive with C3 EMC filter and Modbus — verified condition, ready…

In Stock

Schneider Electric

BMXXBP1200

Genuine surplus Schneider Electric BMXXBP1200 12-slot rack for Modicon M340 — verified condition, sourcing support from Autronexa.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: TSXAEY414

We reply within one business day.

TSXAEY414 Quote reply within 1 business day