Schneider Electric Drives & Inverters
Schneider Electric ATV610D45N4Z
Variable speed drive
Genuine surplus Schneider ATV610D45N4Z, 45 kW pump/fan drive with C3 EMC filter and Modbus — verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power (normal duty) | 45 kW (60 HP) |
|---|---|
| Heavy duty rating | 37 kW, 74.5 A continuous, 112 A transient (60 s) |
| Supply voltage | 380...460 V AC, 50/60 Hz, three-phase |
| Maximum continuous output current | 88 A (normal duty) |
| Maximum transient current (60 s) | 97 A (normal duty) |
| Integrated EMC filter | Category C3 |
| Built-in communication | Modbus RTU; 2 RJ45 ports |
| Dimensions (H×W×D) | 613 × 226 × 271 mm |
| Weight | 25.295 kg (55.77 lb) |
Description
The ATV610D45N4Z is a Schneider Electric Easy Altivar 610 variable speed drive rated 45 kW (60 HP) normal duty, built for three-phase pumps and fans on a 380…460 V supply with an integrated C3 EMC filter. Maintenance and procurement teams choose genuine surplus or refurbished units of this model to replace failed drives without waiting on OEM lead times, and Autronexa verifies each unit against OEM datasheet markings before it ships.
What This Drive Does in a Pump or Fan System
This is an AC frequency inverter for open-loop three-phase asynchronous and synchronous motors. The 45 kW normal-duty rating pairs with 88 A maximum continuous output current and 97 A transient current for 60 s, so it suits variable-torque fan and pump loads that need headroom during acceleration. A dedicated U/f quadratic (UFQ) control mode is available for variable-torque applications. The integrated DC choke reduces input current harmonics; an optional passive filter (VW3A460xx) can achieve THDi below 10%. The drive carries CE marking (EMC directive) and CSA C22.2 No. 274, and the electronic cards have protective conformal coating for 3C3/3S3 environments.

Surplus Advantage for This Configuration
The N4Z suffix means no plain-text display terminal is supplied; a VW3A1113 keypad connects through the RJ45 HMI port as a separate accessory. That configuration is common in panel builds where the HMI lives on the cabinet door, which makes surplus units of this exact variant practical to redeploy. Autronexa supplies refurbished units tested against OEM datasheet specifications and functionally verified by our sourcing team — genuine parts, verified, with clear lead times instead of the long waits that often come with ordering new from the OEM. Because the Easy Altivar 610 line remains active, surplus stock gives you a same-family replacement without a full redesign.

Specs That Matter and How to Compare
| Parameter | This Unit | Typical Alternative |
|---|---|---|
| Rated power (normal duty) | 45 kW (60 HP) | Lower kW frame |
| Continuous output current | 88 A | Below 88 A |
| Integrated EMC filter | Category C3 | External filter needed |
| Built-in protocol | Modbus RTU | Fieldbus module required |
| Integrated HMI | None (N4Z) | Keypad included |
Three specs deserve attention when comparing options. First, the 88 A continuous rating must match your motor’s full-load current, not just its kW label. Second, the C3 EMC filter is integrated, so you avoid adding an external filter in most industrial environments. Third, the two RJ45 ports split Modbus field-network and HMI multidrop duties, and Slot A accepts a PROFIBUS DP V1 module (VW3A3607) or extended I/O modules if your architecture needs them. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier. Verify the exact model and revision against your existing drive before ordering, and confirm whether you need the VW3A1113 keypad separately. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider ATV610D45N4Z, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it ships. We supply genuine surplus and refurbished automation components, not grey-market copies.
What condition will the drive arrive in?
Our default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa if you need a specific condition grade confirmed before purchase.
How fast can you ship the ATV610D45N4Z?
Lead time depends on current stock. Contact Autronexa for current lead time and availability — surplus and refurbished units are often ready to ship faster than OEM factory orders.
Does this drive include a display keypad?
No. The N4Z configuration ships without a plain-text display terminal. A VW3A1113 keypad can be connected via the RJ45 HMI port as a separate accessory.
Can this drive run on a Modbus network?
Yes. It has built-in Modbus RTU on one RJ45 port, with a second RJ45 port for HMI multidrop. Slot A accepts a PROFIBUS DP V1 module (VW3A3607) if your system uses that fieldbus.
Related & compatible parts
Schneider Electric
170ADM37010
Genuine surplus Schneider Electric 170ADM37010 discrete I/O base — 16 inputs, 8 outputs, 24 V DC, verified and…
Schneider Electric
140CRA21110C
Genuine surplus Schneider Electric 140CRA21110C DIO drop interface for Modicon Quantum — verified condition, ready to ship.
Schneider Electric
TSX1702028
Genuine surplus Schneider Electric TSX1702028 programmable controller — 24 I/O, 110–240 VAC, verified condition and ready to ship.
Schneider Electric
ATV71HD15N4
Genuine surplus Schneider ATV71HD15N4, 15 kW 3-phase drive with integrated EMC filter and graphic terminal. Verified condition, ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…