Schneider Electric I/O & Function Modules
Schneider Electric AS-B872-002
Output module
Genuine surplus Schneider AS-B872-002 analog output module for Modicon 984 — 4-channel 4–20 mA, verified and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Output Type | Analog Output |
|---|---|
| Number of Output Points | 4 points |
| Output Current Range | 4 to 20 mA per channel |
| Compatibility | Modicon 984 Series Controller Platform |
| Electrical Isolation | Yes, output electrically isolated from controller logic |
| Status Indicators | LED indicators |
| Mounting | Any slot within the 800 Series I/O structure |
| Weight | 1.31 lbs (0.60 kg) |
| Surge Withstand | Meets IEEE and ANSI standards |
Description
When an analog output channel drops out on a running Modicon 984 system, every hour of downtime adds cost. The Schneider Electric AS-B872-002 is a four-point analog output module rated 4 to 20 mA per channel, built for the 800 Series I/O structure. Autronexa supplies this module as genuine surplus, verified against OEM datasheet markings before it ships.
What the AS-B872-002 Does in a Modicon 984 System
The module converts controller signals into analog current outputs for field devices. Four output points each carry 4 to 20 mA, so one module covers four loops. Electrical isolation separates the outputs from controller logic, which limits fault propagation between field wiring and the backplane. LED status indicators let technicians confirm channel state at a glance without pulling the module. A non-conductive front panel and integrated handle support safe handling during installation and maintenance. The unit inserts into any slot within the 800 Series I/O structure, so expansion does not require a dedicated slot position. Surge withstand capability meets IEEE and ANSI standards, which matters on plant floors where transient events are routine.

Surplus Sourcing Versus OEM Lead Time
Modicon 984 hardware is long-established, and OEM lead times for legacy I/O modules can stretch well beyond a planned outage window. Surplus and refurbished stock closes that gap. Each unit we list is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. Buyers get a genuine module with documented condition rather than an unverified pull. For maintenance managers holding spares budgets, the surplus route also avoids full OEM list pricing on a platform that is already installed and validated. If your site runs multiple 984 racks, consolidating spare output modules through one verified source simplifies inventory control.

Matching This Module to Your Rack
Before ordering, confirm the exact part number and that your application needs analog current output rather than another I/O type. Check that the target rack is an 800 Series I/O structure with a free slot, and that the Modicon 984 controller platform is the host system. Review whether the four output points and 4 to 20 mA range cover your loop count; sites with more loops need additional modules. Ask for the condition grade and any revision notes before purchase. Autronexa can cross-reference markings and confirm fitment from your existing module’s label. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this AS-B872-002 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the AS-B872-002 arrive in?
Units ship in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade on current stock.
How fast can Autronexa ship this output module?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus units typically move faster than OEM factory orders.
Does this module work with the Modicon 984 controller platform?
Yes. The AS-B872-002 is specified for the Modicon 984 Series Controller platform and mounts in any slot within the 800 Series I/O structure.
Is the AS-B872-002 still supported by Schneider Electric?
Lifecycle status is not stated in our source data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
Schneider Electric
TCSESU053FN0
Genuine surplus Schneider Electric TCSESU053FN0 ConneXium 5-port unmanaged Ethernet switch — verified condition, ready to ship.
Schneider Electric
TSXAEY414
Genuine surplus Schneider Electric TSXAEY414 analog input module — verified condition, faster lead times than OEM, and expert…
Schneider Electric
TSXCAY41
Genuine surplus Schneider Electric TSXCAY41 motion control module for Modicon Premium — 4-axis servo control, verified and ready…
Schneider Electric
SR2B121BD
Genuine surplus Schneider Electric SR2B121BD Zelio Logic smart relay, 12 I/O, 24V DC — verified condition and clear…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…