Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBDAO5260
Digital output module
Genuine surplus Schneider STBDAO5260: 2-channel 115V AC isolated digital output module for Advantys STB. Verified condition, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard digital output module (isolated) |
|---|---|
| Channels | 2 |
| Signal type | 115V AC |
| Output current | 2 A per channel |
| Isolation | 1780V AC field-to-bus |
| Hot swapping | Yes |
| Supply voltage | 115V AC (via PDM) |
| I/O base | STBXBA2000 (18.4 mm) |
| PDM | STBPDT2100 (115/230V AC) |
| Protection rating | IP20 |
Description
When a legacy Advantys STB island loses an output channel, the replacement module must match the existing base and PDM exactly — a mismatch stalls the whole segment. The Schneider Electric STBDAO5260 is a standard 2-channel 115V AC isolated digital output module, and Autronexa supplies it as genuine surplus so maintenance teams can restore the island without redesigning the I/O architecture.
What This Output Module Does in an Advantys STB Island
The STBDAO5260 is an isolated digital output module built for the Advantys STB distributed I/O family. It provides two output channels switching 115V AC loads at 2 A per channel, with 1780V AC field-to-bus isolation separating the load side from the communication backplane. That isolation matters in panels where AC solenoids, contactors, or valve banks share an enclosure with sensitive bus electronics.
The module is designed for hot swapping, so a failed channel can be replaced without powering down the entire island — a practical advantage on continuous-process lines. It mounts on the STBXBA2000 I/O base (18.4 mm) and receives its 115V AC supply through the STBPDT2100 PDM (115/230V AC). The IP20 protection rating suits it to cabinet-mounted installations, not exposed field locations.

Surplus Advantage: Why Refurbished Fits This Discontinued Module
Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. That status changes the sourcing calculation: OEM-channel stock is finite, and migrating a working STB island to X80 means new bases, new wiring, and engineering time. For a single failed output channel, that is rarely the economical path.
Autronexa stocks genuine surplus and refurbished Advantys STB components, and each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before it ships. Buyers get a verified part with a clear lead time instead of an open-ended OEM backorder or an unverifiable grey-market listing. Please verify current lifecycle status and availability with Autronexa before ordering.
Sourcing Checklist Before You Order
Confirm three things. First, the exact model — unit, not a sibling output variant with a different signal type. Second, the base and PDM in your island: this module is specified for the STBXBA2000 base and STBPDT2100 PDM, so verify your existing hardware matches. Third, condition: ask whether the unit is surplus or refurbished and request the verification record.
Because the series is discontinued, also confirm whether your site plans to stay on Advantys STB or migrate. If you are staying, keeping a verified spare on the shelf is the practical move. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric STBDAO5260, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished Schneider Electric components, not grey-market copies.
What condition will the STBDAO5260 arrive in?
Units are supplied in the site default condition, Refurbished, and are tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the verification record for the specific unit in stock.
How fast can you ship this module?
Lead time depends on current stock. Contact Autronexa for the current lead time and availability on the STBDAO5260 before placing your order.
Does the STBDAO5260 work with my existing Advantys STB island?
It is specified for the STBXBA2000 I/O base (18.4 mm) and the STBPDT2100 PDM (115/230V AC), with 115V AC supply via the PDM. Confirm your base and PDM match before ordering.
Is the STBDAO5260 still supported by Schneider Electric?
Schneider Electric lists this module as discontinued, superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and discuss spare-part planning for your STB island.
Related & compatible parts
Schneider Electric
ATV930U15N4
Genuine surplus Schneider ATV930U15N4 Altivar 930 drive — dual-rated 1.5 kW ND / 0.75 kW HD, verified condition…
Schneider Electric
ATV930C25N4F
Genuine surplus Schneider Electric ATV930C25N4F Altivar Process drive — 250 kW ND, IP21 floor-standing, verified condition and lead…
Schneider Electric
ATV610D45N4Z
Genuine surplus Schneider ATV610D45N4Z, 45 kW pump/fan drive with C3 EMC filter and Modbus — verified condition, ready…
Schneider Electric
XBTGT1130
Genuine surplus Schneider XBTGT1130 HMI display: 3.8 in LCD, 320 x 240 pixels, Ethernet/RS232/RS485. Verified condition, ready to…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…