Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBNMP2212
Module
Genuine surplus Schneider STBNMP2212 Advantys STB network interface module — Modbus Plus, 24V DC, verified condition and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Protocols | Modbus Plus |
|---|---|
| Built-in ports | 9-pin SUB-D (DB-9S) |
| Supply voltage | 24V DC |
| Addressable I/O modules | max 32 per island |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 128.3 × 70 × 40 mm |
| Weight | 0.145 kg |
| Lifecycle | Discontinued (superseded by Modicon X80 range) (Last verified: 2026-09) |
Description
The Schneider Electric STBNMP2212 is a standard network interface module for the Advantys STB distributed I/O family, built for maintenance and controls teams still running Modbus Plus islands. Because Schneider has discontinued this NIM in favour of the Modicon X80 range, genuine surplus stock is now the practical route to keeping an existing island online without redesigning the network. Autronexa supplies verified surplus and refurbished units with clear condition notes and current availability.
What This Advantys STB Interface Module Does
The NIM is the head of an Advantys STB island: it owns the network connection and manages the I/O modules attached behind it. This variant carries a single 9-pin SUB-D (DB-9S) built-in port and speaks Modbus Plus, so it slots into the network architecture already wired on site rather than forcing a protocol change. It addresses up to 32 I/O modules per island, which covers typical mid-sized distributed racks. Power comes from a 24V DC supply, and the housing measures 128.3 × 70 × 40 mm at 0.145 kg — compact enough for panel mounting where depth is tight. The IP20 protection rating suits it to clean control cabinets, not washdown or exposed field locations.

Why Genuine Surplus Fits This Discontinued NIM
Schneider lists this module as discontinued and superseded by the Modicon X80 range, which means new-from-OEM supply is no longer the answer for an existing STB island. Replacing the whole island to chase a single failed NIM is rarely the cheapest or fastest path. That is where surplus and refurbished stock earns its place: units are tested against OEM datasheet specifications and functionally verified by our sourcing team before they are offered. You get the correct Modbus Plus interface, the original form factor and the 24V DC supply compatibility your panel was built around, without a migration project. For buyers comparing against grey-market sellers, the difference is traceability — every unit is checked against OEM markings and the part-number cross-reference.
Buyer’s Checklist Before You Order
Start with the network: confirm the island is Modbus Plus and that the DB-9S port matches your cabling, because this NIM will not bridge to another fieldbus. Next, count the I/O modules on the island — the 32-module ceiling is a hard limit, so a larger rack needs a different head module. Check cabinet conditions against the IP20 rating and the 24V DC supply. Then decide condition: surplus, refurbished or new, and ask for the grading in writing. Finally, confirm the exact model and any revision notes, since Advantys STB parts are not interchangeable across every variant. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this STBNMP2212 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished automation components, not grey-market copies, and we will share the verification details for the specific unit on request.
What condition will the module arrive in?
The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available depending on stock, so confirm the condition grading for your order before purchase.
How fast can you ship the STBNMP2212?
Lead time depends on current stock, and the source data does not state a fixed shipping window. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the lead time for the unit we hold.
Does this NIM work with my existing Advantys STB island?
It is the standard network interface module for Advantys STB and supports Modbus Plus over a 9-pin SUB-D (DB-9S) port, addressing up to 32 I/O modules per island. Confirm your island uses Modbus Plus and stays within that module count before ordering.
Is the STBNMP2212 still supported by Schneider Electric?
Schneider Electric lists this module as discontinued and superseded by the Modicon X80 range, last verified 2026-09. For ongoing support options, contact Autronexa to verify OEM support status and discuss surplus availability.
Related & compatible parts
Schneider Electric
TSXDMZ28DR
Genuine surplus TSXDMZ28DR relay I/O base for TSX Micro PLCs — verified condition, tested, and ready to ship…
Schneider Electric
TSXCANCD300
Genuine surplus Schneider Electric TSXCANCD300 CANopen cable, 300 m, IP20 — verified condition and clear lead times from…
Schneider Electric
ATV930D15N4
Genuine surplus Schneider ATV930D15N4 drive — 15 kW ND/11 kW HD, dual-rated, with built-in braking unit. Verified condition,…
Schneider Electric · Advantys STB
STBDDI3230
Genuine surplus Schneider Electric STBDDI3230 2-channel digital input module for Advantys STB — verified condition, practical sourcing support.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…