Schneider Electric I/O & Function Modules Advantys STB

Schneider Electric STBNMP2212

Module

Manufacturer: Schneider Electric Part Number: STBNMP2212

Genuine surplus Schneider STBNMP2212 Advantys STB network interface module — Modbus Plus, 24V DC, verified condition and ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Protocols Modbus Plus
Built-in ports 9-pin SUB-D (DB-9S)
Supply voltage 24V DC
Addressable I/O modules max 32 per island
Protection rating IP20
Dimensions (H×W×D) 128.3 × 70 × 40 mm
Weight 0.145 kg
Lifecycle Discontinued (superseded by Modicon X80 range) (Last verified: 2026-09)

Description

The Schneider Electric STBNMP2212 is a standard network interface module for the Advantys STB distributed I/O family, built for maintenance and controls teams still running Modbus Plus islands. Because Schneider has discontinued this NIM in favour of the Modicon X80 range, genuine surplus stock is now the practical route to keeping an existing island online without redesigning the network. Autronexa supplies verified surplus and refurbished units with clear condition notes and current availability.

What This Advantys STB Interface Module Does

The NIM is the head of an Advantys STB island: it owns the network connection and manages the I/O modules attached behind it. This variant carries a single 9-pin SUB-D (DB-9S) built-in port and speaks Modbus Plus, so it slots into the network architecture already wired on site rather than forcing a protocol change. It addresses up to 32 I/O modules per island, which covers typical mid-sized distributed racks. Power comes from a 24V DC supply, and the housing measures 128.3 × 70 × 40 mm at 0.145 kg — compact enough for panel mounting where depth is tight. The IP20 protection rating suits it to clean control cabinets, not washdown or exposed field locations.

Figure 1: Front view of the Schneider Electric STBNMP2212 Module showing its physical design and enclosure.

Why Genuine Surplus Fits This Discontinued NIM

Schneider lists this module as discontinued and superseded by the Modicon X80 range, which means new-from-OEM supply is no longer the answer for an existing STB island. Replacing the whole island to chase a single failed NIM is rarely the cheapest or fastest path. That is where surplus and refurbished stock earns its place: units are tested against OEM datasheet specifications and functionally verified by our sourcing team before they are offered. You get the correct Modbus Plus interface, the original form factor and the 24V DC supply compatibility your panel was built around, without a migration project. For buyers comparing against grey-market sellers, the difference is traceability — every unit is checked against OEM markings and the part-number cross-reference.

Buyer’s Checklist Before You Order

Start with the network: confirm the island is Modbus Plus and that the DB-9S port matches your cabling, because this NIM will not bridge to another fieldbus. Next, count the I/O modules on the island — the 32-module ceiling is a hard limit, so a larger rack needs a different head module. Check cabinet conditions against the IP20 rating and the 24V DC supply. Then decide condition: surplus, refurbished or new, and ask for the grading in writing. Finally, confirm the exact model and any revision notes, since Advantys STB parts are not interchangeable across every variant. Please verify current lifecycle status and availability with Autronexa before ordering, and contact Autronexa with your part number for verified condition and current availability.

📄 Download Datasheet: STBNMP2212-datasheet.pdf

Frequently asked questions

Is this STBNMP2212 a genuine Schneider Electric module or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished automation components, not grey-market copies, and we will share the verification details for the specific unit on request.

What condition will the module arrive in?

The site default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available depending on stock, so confirm the condition grading for your order before purchase.

How fast can you ship the STBNMP2212?

Lead time depends on current stock, and the source data does not state a fixed shipping window. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the lead time for the unit we hold.

Does this NIM work with my existing Advantys STB island?

It is the standard network interface module for Advantys STB and supports Modbus Plus over a 9-pin SUB-D (DB-9S) port, addressing up to 32 I/O modules per island. Confirm your island uses Modbus Plus and stays within that module count before ordering.

Is the STBNMP2212 still supported by Schneider Electric?

Schneider Electric lists this module as discontinued and superseded by the Modicon X80 range, last verified 2026-09. For ongoing support options, contact Autronexa to verify OEM support status and discuss surplus availability.

Related & compatible parts

Schneider Electric

TSXDMZ28DR

Genuine surplus TSXDMZ28DR relay I/O base for TSX Micro PLCs — verified condition, tested, and ready to ship…

In Stock

Schneider Electric

TSXCANCD300

Genuine surplus Schneider Electric TSXCANCD300 CANopen cable, 300 m, IP20 — verified condition and clear lead times from…

In Stock

Schneider Electric

ATV930D15N4

Genuine surplus Schneider ATV930D15N4 drive — 15 kW ND/11 kW HD, dual-rated, with built-in braking unit. Verified condition,…

In Stock

Schneider Electric · Advantys STB

STBDDI3230

Genuine surplus Schneider Electric STBDDI3230 2-channel digital input module for Advantys STB — verified condition, practical sourcing support.

In Stock

News & guides for Schneider Electric

View all articles

Request a quote for this part

Part number: STBNMP2212

We reply within one business day.

STBNMP2212 Quote reply within 1 business day