Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBDDI3230
Digital input module
Genuine surplus Schneider Electric STBDDI3230 2-channel digital input module for Advantys STB — verified condition, practical sourcing support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard digital input module |
|---|---|
| Channels | 2 (sink) |
| Signal type | 24V DC, IEC/EN 61131-2 Type 2 |
| Isolation | 1500V DC field-to-bus for 1 minute |
| Hot swapping | Yes |
| Supply voltage | 24V DC (via PDM) |
| Bus current | 60 mA @5V DC |
| I/O base | STBXBA1000 (13.9 mm) |
| PDM | STBPDT3100 (24V DC) |
| Protection rating | IP20 |
| Weight | 0.110 kg |
Description
The Schneider Electric STBDDI3230 is a standard 2-channel digital input module for the Advantys STB distributed I/O system. Maintenance and automation teams running legacy STB installations need a genuine replacement when an input channel fails, and this discontinued module is exactly the kind of part Autronexa verifies and supplies as surplus or refurbished stock.
What This Module Does in an STB System
The STBDDI3230 accepts two sink-type digital signals at 24V DC, rated to IEC/EN 61131-2 Type 2. That Type 2 rating matters in practice: it defines the input current and threshold behaviour expected from industrial sensors, so the module behaves predictably with standard 24V DC field devices rather than drifting at the switching margin. Field-to-bus isolation is rated at 1500V DC for one minute, which separates the field wiring from the bus electronics. Hot swapping is supported, so a failed channel can be replaced without shutting down the rest of the island. The module draws 60 mA at 5V DC from the bus and sits on the STBXBA1000 I/O base (13.9 mm wide), powered through the STBPDT3100 24V DC PDM. It carries an IP20 protection rating and weighs 0.110 kg.

Surplus Advantage: Why This Part Still Matters
Schneider Electric lists This unit as discontinued, superseded by the Modicon X80 range (last verified 2026-09). For plants still running Advantys STB islands, that status is the real sourcing problem: the platform is no longer the current line, so OEM-channel availability is limited and a migration to X80 is a project, not a quick fix. A verified surplus or refurbished module keeps the existing island running while a migration is planned on your schedule. Autronexa supplies units tested against OEM datasheet specifications and functionally verified by our sourcing team, so you receive a genuine part with known condition rather than an untested pull. Please verify current lifecycle status and availability with Autronexa before ordering.

Selection and Sourcing Guide
Before you order, confirm the exact model on the failed unit and check that your island uses the STBXBA1000 base and STBPDT3100 PDM, since the module is designed around that combination. Decide whether your application needs surplus or refurbished condition and ask for the condition grading in writing. Compare the alternatives below before committing:
- Genuine surplus or refurbished (Autronexa): correct Advantys STB form factor, verified condition, no re-engineering.
- Modicon X80 migration: supported platform, but requires new hardware, wiring review, and engineering time.
- Grey-market pulls: lower upfront cost, but no verification of authenticity or function.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric STBDDI3230, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the module arrive in?
Units are supplied in the site default condition, refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Ask us for the condition grading on the specific unit before ordering.
How fast can you ship the STBDDI3230?
Lead time depends on current stock. Contact Autronexa for the current lead time and availability on this discontinued Advantys STB module.
Does this module work with my existing Advantys STB island?
It is designed for the STBXBA1000 I/O base (13.9 mm) and STBPDT3100 24V DC PDM. Confirm your island uses that base and PDM combination before ordering.
Is the STBDDI3230 still supported by Schneider Electric?
Schneider Electric lists it as discontinued and superseded by the Modicon X80 range (last verified 2026-09). Contact Autronexa to verify current OEM support status and availability.
Related & compatible parts
Schneider Electric
170DDI16001
Genuine surplus Schneider Electric 170DDI16001 Modicon Momentum 16-channel 24V DC input module — verified condition, ready to ship.
Schneider Electric
140ACI05100SC
Genuine surplus Schneider Electric 140ACI05100SC input module — 32-point, 12/16-bit resolution, verified condition and ready to ship.
Schneider Electric
170INT11001
Genuine surplus Schneider Electric 170INT11001 INTERBUS-S adapter for Modicon Momentum I/O — verified condition, ready to ship.
Schneider Electric
BMXDDO1612
Genuine surplus BMXDDO1612: 16-channel 24V DC transistor output module for Modicon X80, verified and ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…