Schneider Electric PLCs & Controllers
Schneider Electric TSXP47425
Series controller
Genuine surplus Schneider TSXP47425 Modicon controller, verified and ready to ship — 24V DC, 256 digital I/O, Modbus/Ethernet/CANopen/Profibus DP.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated Voltage | 24V DC |
|---|---|
| Input Voltage Range | 20V to 30V DC |
| Rated Current | 1.2 A |
| Power Consumption | 15W |
| Operating Temperature Range | -10°C to +60°C |
| Storage Temperature Range | -25°C to +70°C |
| Degree of Protection | IP20 |
| Communication Interface | Modbus, Ethernet, CANopen, and Profibus DP |
| Memory Capacity | 1MB program memory, 128KB data memory |
| I/O Capacity | 256 digital I/O, 128 analog I/O |
Description
When a Modicon-based line stops because a controller has failed, every hour of downtime adds cost. The Schneider Electric TSXP47425 is a Modicon series controller rated at 24V DC with 15W power consumption, and sourcing a genuine surplus or refurbished unit is often the fastest route back to production. Autronexa supplies verified genuine units with clear lead times.
What This Controller Solves on the Panel
The TSXP47425 addresses the common problem of fitting capable control into a standard enclosure. It runs on a 24V DC rated supply with an input voltage range of 20V to 30V DC and draws 1.2 A, so it suits panels already built around a 24V DC bus. Its IP20 degree of protection and DIN rail mounting keep installation straightforward in control cabinets. The unit measures 130 mm wide, 160 mm high and 115 mm deep and weighs 1.19 kg, which matters when you are matching an existing panel layout without redesign. An integrated, battery-backed real-time clock supports time-sensitive routines, and the operating temperature range of -10°C to +60°C covers typical plant-floor conditions.

Capacity and Communications Under Load
A frequent engineering pain point is running out of I/O or memory mid-project. This controller provides 256 digital I/O and 128 analog I/O points, with 1MB of program memory and 128KB of data memory. The program scan time of 1 ms per 1K of program memory keeps cycle times predictable as logic grows. Four expansion slots let you add modules as requirements expand rather than replacing the controller. For integration, the unit supports Modbus, Ethernet, CANopen and Profibus DP. Integration Note: wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier.

Why Genuine Surplus Fits This Model
OEM lead times on legacy Modicon controllers can stretch while a line sits idle. Autronexa stocks genuine surplus and refurbished automation components, and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. That gives you a practical alternative to full OEM list price without accepting grey-market clones. Because this is a Modicon series controller with four expansion slots and broad protocol support, buyers should confirm the exact model and revision match, the condition grade (surplus versus refurbished), and accessory compatibility before ordering. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine Schneider Electric TSXP47425, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the controller arrive in?
Our default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition grade you need when you request a quote.
How fast can you ship the TSXP47425?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the shipping date before you order.
Does this controller support my existing network?
The unit lists Modbus, Ethernet, CANopen and Profibus DP interfaces. Wiring into such networks may require an external gateway or connection module — confirm required cables and gateways with your supplier before installation.
Is the TSXP47425 still supported by Schneider Electric?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering, and we will confirm what we can about OEM support.
Related & compatible parts
Schneider Electric
BMXDDO6402K
Genuine surplus and refurbished Schneider Electric BMXDDO6402K Modicon X80 64-channel transistor output module, verified and ready to ship.
Schneider Electric
ATV320U15N4B
Genuine surplus ATV320U15N4B drive: 1.5 kW, 380–500 V three-phase, integrated EMC filter, verified and ready to ship.
Schneider Electric
ATV320U22N4B
Genuine surplus Schneider ATV320U22N4B drive, 2.2 kW, 380–500 V three-phase, C2 EMC filter — verified condition and fast…
Schneider Electric
140DDO15310C
Genuine surplus Schneider 140DDO15310C TTL output module — 32 channels, 5 V DC, verified condition and fast lead…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…