Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBART0200
Analog input module
Genuine surplus Schneider Electric STBART0200 Advantys STB 2-channel RTD/TC/mV analog input module — verified condition, sourcing help included.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module Type | Standard analog input module (RTD/TC/mV) |
|---|---|
| Channels | 2 (individually configurable) |
| Signal Type | RTD (Pt100, Pt1000, Ni100, Ni1000, Cu10; 2/3/4-wire), Thermocouple (B, E, J, K, R, S, T), ±80 mV |
| Resolution | 15 bits + sign |
| Maximum Input | ±7.5V DC |
| Isolation | 1500V AC field-to-bus |
| Hot Swapping | Yes |
| Supply Voltage | 24V DC (via PDM) |
| I/O Base | STBXBA1000 (13.9 mm) |
| Protection Rating | IP20 |
Description
When an Advantys STB analog input module fails, the whole I/O segment can stall, and sourcing a genuine replacement quickly matters. The Schneider Electric STBART0200 is a standard 2-channel RTD/TC/mV analog input module for Advantys STB systems. Autronexa supplies it as verified surplus or refurbished stock, giving maintenance and procurement teams a practical alternative to waiting on OEM lead times.
What This Module Does in an Advantys STB Segment
The STBART0200 handles temperature and low-level voltage signals inside an Advantys STB distributed I/O island. Its two input channels are individually configurable, so one module can serve two different sensor types without extra hardware. The signal range is broad: RTD inputs cover Pt100, Pt1000, Ni100, Ni1000 and Cu10 in 2-, 3- or 4-wire connection; thermocouple inputs accept B, E, J, K, R, S and T types; and a ±80 mV range handles millivolt-level sources. Resolution is 15 bits plus sign, which supports fine temperature resolution. Field-to-bus isolation is rated 1500V AC, separating sensor wiring from the bus side. The module supports hot swapping, so a replacement can be fitted without powering down the segment — a real advantage when a sensor channel drops out during production.

Technical Specs That Matter on the Panel
Three values shape installation and spares planning. First, the I/O base is STBXBA1000 at 13.9 mm, so the module occupies a narrow slot in the island and replacement must match that base. Second, supply is 24V DC via the PDM, specifically the STBPDT3100 (24V DC) — confirm the existing PDM before ordering. Third, the maximum input is ±7.5V DC, which defines the safe input ceiling and protects the module from overrange signals. The IP20 protection rating means the module belongs inside an enclosure, not in exposed washdown areas. Note that operating and storage temperature figures are not published in our current data — ask Autronexa for verified values if your panel runs hot.
Surplus Sourcing for a Discontinued Advantys STB Module
This unit is discontinued, superseded by the Modicon X80 range. That status changes the sourcing picture: OEM channels may no longer stock the exact Advantys STB part, while installed islands still need matching modules. Genuine surplus and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the replacement matches the original configuration. For buyers maintaining existing Advantys STB installations, this is often faster than redesigning a segment around a newer platform. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is the STBART0200 a genuine Schneider Electric module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished Schneider Electric modules, not grey-market copies.
What condition will the STBART0200 arrive in?
Units are supplied as refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade of current stock.
How fast can Autronexa ship the STBART0200?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability before ordering.
The STBART0200 is discontinued — can I still get one?
Yes, through genuine surplus and refurbished channels. The module is superseded by the Modicon X80 range, but existing Advantys STB islands still require the original part. Autronexa sources verified units for these installations.
Does the STBART0200 need a specific I/O base and PDM?
It mounts on the STBXBA1000 I/O base (13.9 mm) and is supplied 24V DC via the STBPDT3100 PDM. Confirm your existing base and PDM match before ordering.
Related & compatible parts
Schneider Electric
BMXXBP1200
Genuine surplus Schneider Electric BMXXBP1200 12-slot rack for Modicon M340 — verified condition, sourcing support from Autronexa.
Schneider Electric
ATV610D55N4Z
Genuine surplus Schneider ATV610D55N4Z drive — 55 kW normal duty, C3 EMC filter, Modbus. Verified condition, faster than…
Schneider Electric · Advantys STB
STBDRC3210
Genuine surplus STBDRC3210 relay output module — 2-channel Form C, hot-swappable, verified condition and clear lead times from…
Schneider Electric
ATV61HU40N4
Genuine surplus Schneider Electric ATV61HU40N4 Altivar 61 drive, 4 kW, 380–480 V, verified condition and ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…