Schneider Electric I/O & Function Modules Advantys STB
Schneider Electric STBDDO3600
Digital output module
Genuine surplus Schneider Electric STBDDO3600 6-channel digital output module — verified condition, clear lead times, sourcing help from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Module type | Standard digital output module |
|---|---|
| Channels | 6 (source) |
| Signal type | 24V DC |
| Output current | 2 A per channel @30 °C, 1 A per channel @60 °C |
| Output voltage range | 19.2-30V DC |
| Response time | 715 µs off-to-on, 955 µs on-to-off @0.5 A |
| Isolation | 1500V DC field-to-bus |
| Protection | Electronic overcurrent per group (2 channels per group) |
| Hot swapping | Yes |
| I/O base | STBXBA1000 (13.9 mm) |
| PDM | STBPDT3100 (24V DC) |
| Bus current | 70 mA @5V DC |
| Protection rating | IP20 |
| Weight | 0.114 kg |
Description
When a 24V DC output channel fails on a running Advantys STB island, every hour of downtime adds cost. The Schneider Electric STBDDO3600 is a standard 6-channel source digital output module for Advantys STB distributed I/O, and Autronexa supplies it as genuine surplus with verified condition and clear lead times.
What This Module Does in an Advantys STB Island
The STBDDO3600 drives six source-type outputs at 24V DC, with 2 A per channel at 30 °C derating to 1 A per channel at 60 °C. It accepts an output voltage range of 19.2–30V DC and switches with response times of 715 µs off-to-on and 955 µs on-to-off at 0.5 A. Each pair of channels shares electronic overcurrent protection, so a fault on one output trips its group rather than the whole module. Field-to-bus isolation is rated 1500V DC, which keeps bus-side electronics separated from field wiring faults. The module draws 70 mA at 5V DC from the bus and mounts on the STBXBA1000 I/O base (13.9 mm) with the STBPDT3100 PDM providing 24V DC supply. Hot swapping is supported, so a replacement can be fitted without shutting down the island.

Why Genuine Surplus Fits a Discontinued Module
Schneider Electric has discontinued the Advantys STB range and superseded it with the Modicon X80 range, so new-from-OEM stock is no longer the practical route for this module. That is where surplus and refurbished stock earns its place: units are tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. For maintenance teams keeping existing STB islands running, a verified surplus module avoids the redesign cost of migrating an entire I/O drop to a new platform. Autronexa holds genuine surplus and refurbished automation components across Allen-Bradley, Bently Nevada, Siemens, Schneider and more, and can confirm condition and current availability against your part number.

Sourcing Checks Before You Order
Confirm the exact model and any revision markings on the failed unit before ordering, because the STB range includes several output variants that are not interchangeable. Check that your island uses the STBXBA1000 base and STBPDT3100 PDM, since the module’s supply and mounting depend on them. Decide whether you need a surplus unit or a refurbished one, and ask for the condition grading in writing. Because lifecycle status is discontinued, please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this STBDDO3600 a genuine Schneider Electric module or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. We supply genuine surplus and refurbished components, not grey-market copies.
What condition will the STBDDO3600 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — request the condition grading with your quote.
How fast can you ship the STBDDO3600?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we confirm lead time before you commit.
Does the STBDDO3600 work with my existing Advantys STB island?
It mounts on the STBXBA1000 I/O base (13.9 mm) and takes 24V DC supply via the STBPDT3100 PDM. Confirm your island uses these before ordering, as other STB bases and PDMs are not interchangeable.
Is the STBDDO3600 still supported by Schneider Electric?
The Advantys STB range is discontinued and superseded by the Modicon X80 range. Contact Autronexa to verify OEM support status and current availability for your application.
Related & compatible parts
Schneider Electric · Advantys STB
STBNCO2212
Genuine surplus Schneider STBNCO2212 Advantys STB CANopen network interface module — verified condition, ready to ship.
Schneider Electric
170FNT11000
Genuine surplus Schneider Electric 170FNT11000 Fipio adapter for Modicon Momentum — verified condition, 1 Mbps, ready to ship.
Schneider Electric
ATV320U55N4B
Genuine surplus Schneider ATV320U55N4B 5.5 kW drive — verified condition, tested against OEM specs, ready to ship.
Schneider Electric
140CRA31908
Genuine surplus Schneider 140CRA31908 Ethernet RIO drop adaptor for Modicon Quantum — verified condition, ready to ship.
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…