Schneider Electric I/O & Function Modules
Schneider Electric 140HLI34000
I/O & Function Modules
Modicon Quantum - latch/interrupt module - 16 I - fast isolated 140HLI34000 Main Range of Product Modicon Quantum automation platform Product or Component Type Latch/interrupt module Complementary Number of inputs…
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Number of inputs | 16 |
|---|---|
| Absolute maximum input | 30 V DC |
| Voltage state 0 guaranteed | -3...5 V |
| Voltage state 1 guaranteed | 15...30 V |
| Current state 0 guaranteed | 2...8 mA |
| Current state 1 guaranteed | <= 0.5 mA |
| Response time | 130 µs Off-On |
| Reverse polarity protection | Internal in 30 V |
| Isolation between channels | 500 V 60 s AC |
| Bus current requirement | 400 mA |
| Power dissipation | 2.0 W + (0.3 x number of points on) |
| Resistance to electrostatic discharge | 4 kV contact IEC 801-2 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3 |
| Ambient air temperature for operation | 32…140 °F (0…60 °C) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) |
| Relative humidity | 95 % without condensation |
| Operating altitude | <= 16404.2 ft (5000 m) |
| Standards | UL 508 |
Description
The 140HLI34000 is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number
Electrical Ratings
Voltage state 0 guaranteed is -3…5 V. Match this against the supply available at the installation site, including any tolerance on the incoming feed. Voltage state 1 guaranteed is 15…30 V. Match this against the supply available at the installation site, including any tolerance on the incoming feed. Current state 0 guaranteed is 2…8 mA. Confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Current state 1 guaranteed is <= 0.5 mA. Confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Bus current requirement is 400 mA. Confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Power dissipation is 2.0 W + (0.3 x number of points on). Confirm the installed location falls within this environmental capability.
Input Characteristics & Isolation
Absolute maximum input is 30 V DC. Use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Response time is 130 µs Off-On. Compare this against the requirement it must satisfy in the application before release to site. Reverse polarity protection is Internal in 30 V. Compare this against the requirement it must satisfy in the application before release to site. Isolation between channels is 500 V 60 s AC. This defines what the part reads or drives; confirm it matches the transducer or signal source wired to it.
Environmental & Compliance Ratings
Resistance to electrostatic discharge is 4 kV contact IEC 801-2. Use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Resistance to electromagnetic fields is 9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3. Use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Ambient air temperature for operation is 32…140 °F (0…60 °C). Check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Ambient air temperature for storage is -40…185 °F (-40…85 °C). Check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Relative humidity is 95 % without condensation. Maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms. Operating altitude is <= 16404.2 ft (5000 m). Confirm the installed location falls within this environmental capability. Standards is UL 508. Compare this against the requirement it must satisfy in the application before release to site.
Mechanical & Dimensional Data
Number of inputs is 16. Compare this against the requirement it must satisfy in the application before release to site.
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record.
Request a Quote
Autronexa supplies the 140HLI34000 as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the 140HLI34000?
Schneider Electric 140HLI34000 is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the 140HLI34000 in stock, and what is the lead time?
We list the 140HLI34000 as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the 140HLI34000?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the 140HLI34000 be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the 140HLI34000 together with your application details and we will confirm compatibility and alternatives.
What is the 140HLI34000 and what is it used for?
The 140HLI34000 is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
How do I confirm the 140HLI34000 is the correct replacement?
Compare the part number on the unit being replaced with the ordering code for this entry, character by character including any option suffix, then check the values in the technical specification table against the nameplate on the existing unit.
Related & compatible parts
Schneider Electric
BMEH584040C
Genuine surplus Schneider BMEH584040C redundant processor for Modicon M580 — verified condition, faster than OEM lead times.
Schneider Electric
170ADI35000
Genuine surplus Schneider Electric 170ADI35000 Modicon Momentum 32-channel 24V DC input module — verified condition, sourcing help, faster…
Schneider Electric
PC-E984-285C
Genuine surplus PC-E984-285C compact controller with 32K logic memory, 256 digital I/O, and PROFIBUS-DP — verified and ready…
Schneider Electric
170AAO92100
Genuine surplus Schneider Electric 170AAO92100 analog output base module — 4 outputs, 16-bit signed, verified condition and ready…
News & guides for Schneider Electric
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Schneider Electric at Datacenter Korea 2026 and Tech Show Madrid: The Integrated AI Data Center Stack
Schneider Electric is pitching an integrated AI data center stack — power, cooling, and software as one system — at…
Schneider Electric spare parts: buying guide, series overview and how to order
Schneider Electric spare parts buying guide: 8 parts online, popular series, condition options and how our RFQ process works.
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
EPC’s New 100 V GaN Inverter Boards: 35 ARMS, 100 kHz, 80 V Bus
In short: On 27 October 2026 EPC announced the EPC91124 and EPC91125, two 100 V three-phase BLDC inverter evaluation boards…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…