Allen-Bradley PLCs & Controllers 1734 / 1746 / 1762 / 1794 Series
Allen-Bradley 1746-NIO4V
PLCs & Controllers
The Allen-Bradley 1746-NIO4V is an SLC500 analog combination module. This module features Two (2) differential, voltage or current selectable per channel with input signal ranges of -20 to +20 mA (or) -10 to +10V dc and Two (2) current outputs with signal range of 0 to +20 mA. Technical specifications for 1746-NIO4V.
- New Surplus
- Available on request
Availability & pricing
| Condition | Price | Stock / lead time | Action |
|---|---|---|---|
| New Surplus | On request | Available on request |
Ships within 7 business days
Technical specifications
| Manufacturer | Rockwell Automation |
|---|---|
| Module Type Analog | combination module |
| Series | SLC500 |
| Part Number/Catalog No. | 1746-NIO4V |
| Brand | Allen-Bradley |
| No. | of inputs Two (2) Differential Voltage / Current inputs |
| Current Input | range -20 to 20 mA |
| Current | input resolution 1.22070 µA per LSB |
| Voltage Input | range -10 to +10V dc - 1 LSB |
| Voltage | input resolution 305.176 µV per LSB |
| No. | of Outputs Two (2) non-isolated voltage outputs |
| Output Voltage | range -10 to +10 volts |
| Output | voltage resolution 1.22070 mV per LSB |
| Backplane Current | at 5.1 Volts 0.55 mA |
| Backplane Current | at 24 Volts 115 mA |
| Inputs | 2 |
| Outputs | 2 |
| Backplane Current | (5 Volts) 55 milliamps |
| Backplane Current | (24 Volts) 115 milliamps |
| Bandwidth | 10 Hertz |
| Update Time | 512 microseconds |
| Resolution | 16 bits in, 14 bits out |
| Step Response | 60 milliseconds in, 2.5 milliseconds out |
| Mounting Rack | mount |
| UPC | 10662073735899 Description |
Description
The Rockwell Automation 1746-NIO4V is a catalog part supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: voltage input range -10 to +10V dc – 1 LSB
Electrical Ratings
Current Input is range -20 to 20 mA. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Current is input resolution 1.22070 µA per LSB. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Voltage Input is range -10 to +10V dc – 1 LSB. match this against the supply available at the installation site, including any tolerance on the incoming feed. Voltage is input resolution 305.176 µV per LSB. match this against the supply available at the installation site, including any tolerance on the incoming feed. Output Voltage is range -10 to +10 volts. match this against the supply available at the installation site, including any tolerance on the incoming feed. Output is voltage resolution 1.22070 mV per LSB. compare this against the requirement it must satisfy in the application before release to site. Backplane Current is at 5.1 Volts 0.55 mA. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Backplane Current is at 24 Volts 115 mA. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Outputs is 2. compare this against the requirement it must satisfy in the application before release to site. Backplane Current is (5 Volts) 55 milliamps. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Backplane Current is (24 Volts) 115 milliamps. confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure.
Mechanical & Dimensional Data
Bandwidth is 10 Hertz. take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Mounting Rack is mount. verify the mating thread and fitting size on site before ordering, because these are not interchangeable across the series.
Additional Verified Data
Module Type Analog is combination module. Part Number/Catalog No. is 1746-NIO4V. No. is of inputs Two (2) Differential Voltage / Current inputs. No. is of Outputs Two (2) non-isolated voltage outputs. Inputs is 2. Update Time is 512 microseconds. Resolution is 16 bits in, 14 bits out. Step Response is 60 milliseconds in, 2.5 milliseconds out.
Models in This Series
Autronexa currently lists this product entry as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.
Confirming the Correct Variant Before Ordering
Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the voltage input available at the installation site is range -10 to +10V dc – 1 LSB, which is the documented requirement for this model.
Request a Quote
Rockwell Automation supplies the 1746-NIO4V as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.
Frequently asked questions
What is the 1746-NIO4V?
Allen-Bradley 1746-NIO4V is an industrial automation component we supply from surplus and refurbished stock. Confirm the exact configuration, condition and lead time with our team before purchase.
Is the 1746-NIO4V in stock, and what is the lead time?
We list the 1746-NIO4V as in stock in New Surplus condition. Request a quote for current availability, pricing and confirmed lead time — most items ship within 1–3 business days.
Do you provide a datasheet for the 1746-NIO4V?
Where available, the product page links the original manufacturer datasheet (PDF). Use the request-a-quote form to receive the full documentation pack and compliance information.
Can the 1746-NIO4V be cross-referenced to an equivalent?
Many automation parts have equivalents or legacy replacements. Send us the 1746-NIO4V together with your application details and we will confirm compatibility and alternatives.
What input voltage does the 1746-NIO4V use?
The Rockwell Automation 1746-NIO4V operates at range -10 to +10V dc - 1 LSB. Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.
What is the 1746-NIO4V and what is it used for?
The Rockwell Automation 1746-NIO4V is a industrial component device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.
What supply voltage does the 1746-NIO4V need?
The manufacturer documentation lists voltage input range -10 to +10V dc - 1 LSB. for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.
Related & compatible parts
Allen-Bradley
22C-D060A103
Genuine surplus Allen-Bradley 22C-D060A103 PowerFlex 400 drive, 30 kW at 60 A with built-in RS-485 and verified condition.
Allen-Bradley
1790D-T0W6
Allen-Bradley 1790D-T0W6 I/O & Function Modules. Output delay time Off to On: 10 ms max, On to Off:…
Allen-Bradley
22C-D088A103
Genuine Allen-Bradley 22C-D088A103: 45.0 kW (60 HP), 88 A PowerFlex 400 fan-and-pump drive with fixed keypad and built-in…
Allen-Bradley
150-F1250NBA
Genuine surplus Allen-Bradley 150-F1250NBA solid state controller, 1250 A, open enclosure, verified and ready to ship.
News & guides for Allen-Bradley
Allen-Bradley spare parts: buying guide, series overview and how to order
Allen-Bradley spare parts buying guide: 16 parts online, popular series, condition options and how our RFQ process works.
Allen-Bradley spare parts: how to confirm the exact replacement
Specifying the correct Allen-Bradley replacement starts with the exact catalog number, not just the family. A 2097-Kinetix drive, a 1746…
SMC-Flex 150-F Soft Starter Guide: Current Frames, Control Voltage and Lug Kits
SMC-Flex soft starters are usually replaced after a trip that will not reset, not after a planned upgrade. That puts…
PowerFlex 400 (22C) Selection Guide: Catalog Codes, Ratings and Enclosures
A PowerFlex 400 purchase is rarely a question about the family. It is a question about which of the 20…
Rockwell 1718/1719-AENTR DoS: CVE-2026-9140 and the 3.012 Fix
Rockwell SD1778: a UDP unicast storm can knock 1718/1719 Ex I/O EtherNet/IP adapters offline until a power cycle. CVE-2026-9140 scores…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Rockwell CompactLogix 5390: 43% Smaller, 128 Axes, Built-In Security
Rockwell's CompactLogix 5390 is 43% smaller than the 5380, with 128 motion axes, 32 PointMax I/O modules and IEC 62443-4-2…
22 Powerflex series guide: configurations in stock and how to order
All 22 Powerflex configurations listed on this site, ordering notes for New Surplus parts, and answers to the most common…
