ABB I/O & Function Modules

ABB AI910S

ABB Analog Input Module

Manufacturer: ABB Part Number: AI910S

Genuine surplus ABB AI910S analog input module for S900 I/O — 4-channel 4...20 mA, ATEX Zone 1, verified condition and ready to ship.

  • 12 Month
  • Refurbished
  • In Stock
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Article number 3KDE175511L9100
Number of channels 4
Signal type 4...20 mA
HART No
Intrinsic safety Yes
Hazardous location ATEX Zone 1
Corrosive atmosphere ISA-S71.04 G3
Ambient temperature -20 °C...60 °C
Dimensions (W x D x H) 20 mm x 104 mm x 104 mm
Weight 0.14 kg

Description

When a remote I/O station must feed four loop-powered transmitters inside a Zone 1 hazardous area, the wiring and certification burden can stall a maintenance window. The ABB AI910S analog input module answers that challenge: a genuine S900 I/O card that supplies and reads 4…20 mA two-wire devices while carrying ATEX Zone 1 approval. Autronexa stocks verified surplus and refurbished units for buyers who need the exact configuration without OEM lead time.

What the AI910S Does in an S900 I/O Station

This unit (article number 3KDE175511L9100) is a four-channel analog input card in ABB’s S900 I/O family. It provides both the input and the power supply for 4…20 mA loop-powered two-wire transmitters, so field devices connect directly without separate supply hardware. Each channel offers short and break detection, and electrical isolation separates input from bus and input from power. A common return serves all four inputs. The card is built for the S900 I/O type S variant, which installs in hazardous area Zone 1 and connects intrinsically safe field devices located in Zone 2, Zone 1 or Zone 0. Because the S900 system communicates with the control level over PROFIBUS DP, this module fits existing remote I/O architectures rather than requiring a new network layer. The G3 coating protects all components against corrosive atmospheres rated ISA-S71.04 G3, and the module operates from -20 °C to 60 °C at up to 93 % relative humidity.

Figure 1: Front view of the ABB AI910S ABB Analog Input Module showing its physical design and enclosure.

Why Genuine Surplus Fits This Module

Hazardous-area I/O cards are rarely stocked deeply by distributors, and a single failed channel can hold an entire Zone 1 marshalling cabinet offline. Autronexa sources surplus and refurbished ABB S900 modules and verifies each unit against OEM datasheet markings and part-number cross-reference before it ships. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. For this card, that means confirming the four input channels, the loop power supply behaviour, and the isolation boundaries described in the datasheet. The practical result is a shorter path to a spare than a factory order, with condition stated clearly before purchase. Please verify current lifecycle status and availability with Autronexa before ordering.

Sourcing Checklist for This unit

Before committing to a replacement, confirm the article number 3KDE175511L9100 matches your existing card — This unit designation alone can appear across S900 documentation. Check that your application needs the Ex variant for Zone 1 installation rather than a non-hazardous S900 card, and that four 4…20 mA channels with a common return suit your field wiring. Note that HART is not supported on this type, and redundancy is listed as No, so verify those points against your loop design. Ask for the condition grade — surplus or refurbished — and request the verification record. Autronexa supplies genuine parts, verified, with technical sourcing help across ABB and related automation brands. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is this AI910S a genuine ABB module or a clone?

Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, including the article number 3KDE175511L9100, before it is listed. We supply genuine surplus and refurbished automation components, not grey-market copies.

What condition will the AI910S arrive in?

Our default condition is Refurbished: units are tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the condition grade with Autronexa before ordering.

How fast can you ship the AI910S?

Lead time depends on current stock. Contact Autronexa for the current lead time and availability for article number 3KDE175511L9100.

Does the AI910S work with our existing S900 I/O station?

The module is part of the S900 I/O type S system, which communicates with the control level using PROFIBUS DP. Confirm your station variant and backplane compatibility with Autronexa before ordering.

Is the AI910S still supported by ABB?

Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.

Related & compatible parts

ABB

V18345-1010120001

Genuine surplus ABB TZIDC positioner, 4–20 mA two-wire, IP 65, single-acting fail-safe — verified condition, ready to ship.

In Stock

ABB

DI802

Genuine ABB DI802 8-channel 120 V a.c./d.c. digital input module for S800 I/O — individually isolated channels, verified…

In Stock

ABB

TU890

Genuine surplus ABB TU890 MTU for S800 I/O — verified condition, 8 channels, intrinsic-safety ready, ready to ship…

In Stock

ABB

DO801

Genuine surplus ABB DO801 16-channel 24 V digital output module for S800 I/O — verified condition, tested, and…

In Stock

News & guides for ABB

View all articles

Request a quote for this part

Part number: AI910S

We reply within one business day.

AI910S Quote reply within 1 business day