ABB CI845
Ethernet networked
Genuine surplus ABB CI845 Ethernet FCI module for Select I/O and S800 — verified, tested, and ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3BSE075853R1 |
|---|---|
| Communication Protocol | Ethernet |
| Type | Ethernet FCI Module |
| Master or Slave | Slave |
| HART | Yes |
| SOE | Yes |
| Redundancy | Yes |
| Hot Swap | Yes |
| Input Voltage Range | 19.2 ... 30 V |
| Power Dissipation | 5 W |
| Operating Temperature | -40 °C (-40 °F) to +70 °C (158 °F) |
| Protection Class | IP20 acc. to IEC 60529 |
| Dimensions (W x D x H) | 30 mm x 121.7 mm x 135 mm |
| Weight (including base) | 225 g |
Description
The ABB CI845 is an Ethernet Fieldbus Communication Interface module that links S800 I/O and Select I/O to AC 800M controllers. For maintenance and procurement teams running ABB Ability System 800xA, a verified surplus or refurbished unit keeps redundant architectures intact without OEM lead-time delays.
What This Module Does in an ABB System
The CI845 acts as a slave communication interface, handling data exchange between I/O racks and the controller over Ethernet. It supports both Select I/O and S800 on the same network, accommodating up to 12 single or 12 redundant S800 I/O modules, or up to 192 Select I/O channels. Redundant configurations require two units installed in a TU860 or TU865 MTU, and the module supports hot swap — a practical advantage when replacing a failed unit in a running line. Built-in diagnostics cover internal hardware, communication, incoming power supplies A and B, and cabinet temperature, giving maintenance staff actionable fault data without external tools. HART v7 pass-through and Sequence of Events support are included, and the module carries ATEX and IECEx hazardous-area ratings for Zone 2 installations.

Technical Specifications That Matter on Site
The 19.2 to 30 V input voltage range with built-in power voting and supervision of both supply inputs allows the module to ride through common plant power variations. Galvanic isolation between the power supply and I/O modules protects sensitive field wiring from ground loops. At 5 W power dissipation, the unit adds minimal heat load inside sealed cabinets. The operating temperature range of -40 °C to +70 °C suits both climate-controlled control rooms and harsher field enclosures. Measuring 30 mm wide, 121.7 mm deep, and 135 mm high at 225 g including base, it fits standard Select I/O cabinet layouts without rework. A mechanical locking slider cuts power before removal, and mechanical keying prevents incorrect module insertion.

Surplus Sourcing for This unit
ABB 800xA systems often stay in service for decades, and OEM lead times for communication modules can stretch well beyond planned maintenance windows. Autronexa supplies genuine surplus and professionally refurbished unit units tested against OEM datasheet specifications and functionally verified by our sourcing team. Each unit is checked for communication integrity, power supervision, and diagnostic function before dispatch. Because this module is often stocked as a critical spare, we help maintenance teams avoid the cost and delay of buying new from the OEM while keeping the original ABB form factor and firmware compatibility. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB CI845, or a clone?
Autronexa verifies every CI845 against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units only — no grey-market copies.
What condition will the CI845 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — contact us for current stock and grading.
How fast can you ship the CI845?
Lead time depends on current stock. Contact Autronexa for verified availability and dispatch timing for your location.
Does the CI845 work with both Select I/O and S800?
Yes. The module supports both Select I/O and S800 on Ethernet, with capacity for up to 12 single or 12 redundant S800 I/O modules or up to 192 Select I/O channels.
Is the CI845 still supported by ABB?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
ABB
SD833
Genuine surplus ABB SD833 power supply: 24 V DC, 10 A, 240 W, DIN-rail, SELV/PELV. Verified condition and…
ABB
V18345-1010221001
Genuine surplus ABB TZIDC-120 valve positioner, 4–20 mA two-wire, IP 65, with analog feedback. Verified condition, ready to…
ABB
DI830
Genuine surplus ABB DI830 16-channel digital input module for S800 I/O — verified condition, faster than OEM lead…
ABB
TU814V1
Genuine surplus ABB TU814V1 termination unit — 16 I/O channels, 50 V rated, crimp snap-in connectors. Verified condition,…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…