ABB CI801
Comprehensive
Genuine surplus ABB CI801 PROFIBUS DP-V1 interface — verified condition, faster than OEM lead time, sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3BSE022366R1 |
|---|---|
| Communication protocol | PROFIBUS DP-V1 |
| Master or slave | Slave |
| 24 V consumption | typ. 140 mA |
| Operating temperature | 0 to +55 °C (+32 to +131 °F), approvals issued for +5 to +55 °C |
| Protection class | IP20 according to EN60529, IEC 529 |
| Dimensions (W × H × D) | 85.8 mm × 136 mm × 58.5 mm |
| Weight | 0.3 kg (0.66 lbs.) |
Description
When a PROFIBUS DP-V1 segment needs a reliable communication interface, the ABB CI801 Fieldbus Communication Interface module keeps S800 I/O talking to the parent controller. Maintenance teams and integrators choose genuine surplus or refurbished units for this exact model because verified condition and faster availability beat waiting on factory lead times.
What the CI801 Does in an S800 I/O System
The S800 I/O family is a distributed, modular process I/O system that communicates with controllers over industry-standard field buses. This unit sits at the heart of that link as a configurable communication interface. It performs signal processing, gathers supervision information, handles OSP (output set as predetermined) behavior, supports Hot Configuration InRun, passes HART data through, and configures the I/O modules on its ModuleBus. It connects to the controller over PROFIBUS-DPV1 and operates as a slave, so it responds to the master controller rather than initiating bus traffic. Because it is used together with HI Controllers, this module is a practical fit for existing ABB installations that need a like-for-like replacement rather than a redesign. The unit also provides an isolated power supply to the I/O modules and a fused input power path, which protects downstream electronics from a fault on the supply side.

Technical Specs That Matter on the Bus
Power draw is modest: typical 24 V consumption is 140 mA, so the module adds little load to an existing 24 V rail. Environmental ratings shape where the unit can live. Operating temperature spans 0 to +55 °C, though approvals are issued for +5 to +55 °C, and vertical mounting lowers the maximum ambient to 40 °C. Storage range is -40 to +70 °C. The housing is IP20 per EN60529 and IEC 529, with pollution degree 2 per IEC 60664-1 and corrosion protection to ISA-S71.04: G3. Relative humidity of 5 to 95 % non-condensing is acceptable. The module measures 85.8 mm wide, 136 mm high including latch, and 58.5 mm deep, and weighs 0.3 kg. Electrical safety follows EN 61010-1, UL 61010-1, EN 61010-2-201, and UL 61010-2-201. Hazardous-location approvals cover C1 Div 2 cULus, C1 Zone 2 cULus, and ATEX Zone 2, and marine certificates include ABS, BV, DNV-GL, and LR. CE marking and RoHS compliance under DIRECTIVE/2011/65/EU (EN 50581:2012) are both stated.

Why Genuine Surplus Fits This Module
New-from-OEM lead times on process I/O communication modules can stretch while a line waits. A verified surplus or refurbished unit keeps the existing architecture intact — no re-engineering, no new bus configuration — and typically costs less than OEM list price. Autronexa sources these units as genuine parts, verified against OEM datasheet markings and part-number cross-references, and functionally tested by our sourcing team. Because the module is used with HI Controllers and supports Hot Configuration InRun, a tested replacement can be swapped in with minimal disruption to a running configuration. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB CI801, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished automation components, not grey-market copies.
What condition will the CI801 arrive in?
Units are supplied in refurbished condition, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the specific condition grade of the unit in stock.
How fast can you ship the CI801?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does the CI801 work with my existing S800 I/O and HI Controller setup?
The module is designed for use with HI Controllers over PROFIBUS-DPV1 as a slave interface. Confirm your controller and bus configuration with Autronexa before ordering.
Is the CI801 still supported by ABB?
Lifecycle status is not stated in our data. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
ABB
AI930B
Genuine surplus ABB AI930B analog input module — 4 channels, 4...20 mA, HART, ATEX Zone 2. Verified condition,…
ABB
DI821
Genuine surplus ABB DI821 digital input module for S800 I/O — 8 isolated channels, 230 V a.c./220 V…
ABB
AI910N
Genuine surplus ABB AI910N analog input module for S900 I/O — 4 channels, 4...20 mA, G3 coating, verified…
ABB
DI828
Genuine surplus ABB DI828 digital input module — 16 isolated channels, 120V AC/DC, verified and ready to ship.
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…