ABB CI855
Also implemented
Genuine surplus ABB CI855 MasterBus 300 interface for AC 800M — verified condition, peer-to-peer bridge to legacy Advant controllers, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Communication protocol | ABB's MasterBus 300 |
|---|---|
| Transmission speed | 10 Mbit/s, 200 Datasets/s |
| Master or slave | Master |
| Line redundancy | Yes |
| Hot swap | Yes |
| Max units on CEX bus | 12 |
| Connector | RJ-45 female (8-pin) |
| 24 V consumption | typ. 150 mA |
| Operating temperature | 0 to +55 °C (+32 to +131 °F) |
| Protection class | IP20 according to EN60529, IEC 529 |
Description
The ABB CI855 is a MasterBus 300 communication interface module for the AC 800M controller, letting new System 800xA plant sections exchange data peer-to-peer with legacy Advant OCS and MasterPiece controllers. Maintenance and automation teams sourcing this module need a genuine, verified unit — not a clone — because it carries live process data between old and new control layers. Autronexa supplies tested surplus and refurbished units with clear lead times.
What the CI855 Does in an AC 800M System
The module implements ABB’s MasterBus 300 protocol inside the AC 800M controller, connecting to the CEX-Bus through a TP853 baseplate. That baseplate carries RJ45 connectors for two Ethernet ports, enabling network redundancy, and mounts simply on DIN rail. The interface runs as a master on the bus at 10 Mbit/s and handles up to 200 datasets per second. It supports clock synchronization, DataSet communication, and hot swap, so a faulty module can be replaced without a full rack shutdown. Up to 12 units can sit on one CEX-Bus. The practical payoff is peer-to-peer communication between new 800xA sections and existing MB 300-based controllers such as Advant Controller 410, Advant Controller 450, and MasterPiece 200/1.

Surplus Advantage for This Interface
Legacy bridge modules like This unit sit at the seam between supported and retired platforms, and OEM lead times on such interfaces can stretch while a line waits. A genuine surplus or refurbished unit removes that wait. Autronexa’s refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. Because the module is hot-swappable, a verified spare on the shelf turns a potential outage into a short maintenance window. Compare sourcing routes below.
| Sourcing Route | Lead Time | Condition | Verification |
|---|---|---|---|
| OEM new | Often extended for legacy bridges | New | OEM |
| Grey market | Variable | Unknown | Unverified |
| Autronexa surplus/refurbished | Clear, quoted per unit | Refurbished | Tested and functionally verified |
Selection and Sourcing Checks
Before ordering, confirm the article number on the module label matches your system documentation; This unit carries article number 3BSE018106R1, while the related 3BSE018133R1 designation also appears in ABB literature, so state both when requesting a quote. Verify whether your installation needs the TP853 baseplate, since the module connects through it. Confirm the CEX-Bus unit count stays within the 12-unit limit. Decide between surplus and refurbished condition based on criticality. The module is rated IP20, operates from 0 to +55 °C, and draws typically 150 mA at 24 V. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB CI855, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before listing. We supply genuine surplus and refurbished modules, not grey-market copies.
What condition will the CI855 arrive in?
Our default is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available — state your preferred condition when requesting a quote.
How fast can you ship the CI855?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; we quote lead time per unit.
Does the CI855 work with legacy Advant controllers?
Yes. It implements MasterBus 300 in the AC 800M and enables peer-to-peer communication with MB 300-based controllers including Advant Controller 410, Advant Controller 450, and MasterPiece 200/1.
Is the CI855 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
AI930B
Genuine surplus ABB AI930B analog input module — 4 channels, 4...20 mA, HART, ATEX Zone 2. Verified condition,…
ABB
07 KT 98
Genuine surplus ABB 07 KT 98 Controller 31 basic unit — verified condition, CS31 field bus, 24 DI/16…
ABB
TU847
Genuine surplus ABB TU847 termination unit for redundant CI840/CI840A — verified condition, faster than OEM lead time.
ABB
AO810
Genuine surplus ABB AO810 analog output module with 8 channels, 14-bit resolution, and open-circuit diagnostics — verified and…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…