ABB CI854B
High speed multipurpose bus protocol
Genuine surplus ABB CI854B PROFIBUS DP-V1 master interface with dual ports, line and master redundancy, and hot swap support.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Communication protocol | PROFIBUS DP-V1 |
|---|---|
| Master or slave | Master |
| Number of channels | 2 |
| Transmission speed | 9.6 - 12 000 kbit/s |
| Line redundancy | Yes |
| Module redundancy | Yes |
| Hot Swap | Yes |
| 24 V consumption | typ. 190 mA |
| Operating temperature | 0 to +55 °C (+32 to +131 °F) |
| Protection class | IP20 according to EN60529, IEC 529 |
Description
When a PROFIBUS DP segment drops offline, every remote I/O rack and drive behind it stops reporting. The ABB CI854B communication interface restores that link for AC 800M controllers, and Autronexa supplies it as a verified genuine surplus module with clear lead times.
What This Interface Solves on an AC 800M
The CI854B connects PROFIBUS DP field devices — remote I/O, drives, low-voltage electrical equipment, and controllers — to the AC 800M controller. It runs PROFIBUS DP-V1 as a master with two DB female 9-pin channels, so one module can serve two segments or a redundant line pair. Transmission speed spans 9.6 to 12 000 kbit/s, letting you match the bus rate to cable length and device count rather than rebuilding the network. Each module is delivered with a unitK01 communication interface and a TP854 baseplate, so the mounting hardware arrives with the part. The module mounts on DIN rail and interfaces directly with the S800 I/O system and other PROFIBUS DP/DP-V1 and FOUNDATION Fieldbus proficient systems.

Redundancy and Hot Swap Without a Full Shutdown
A single master is a single point of failure. This unit supports line redundancy through its two PROFIBUS ports and master redundancy when two modules are paired; that master redundancy can be combined with CPU redundancy and CEXbus redundancy using the BC810. Hot swap support means a failed module can be replaced while the system stays powered, which shortens the window between fault detection and restored communication. The module draws typically 190 mA at 24 V and operates from 0 to +55 °C, with storage rated -40 to +70 °C. It carries CE marking, marine certificates from ABS, BV, DNV-GL and LR, and RoHS and WEEE compliance. Please verify current lifecycle status and availability with Autronexa before ordering.

Why Genuine Surplus Fits This Module
OEM lead times on 800xA communication hardware can stretch well beyond a planned outage window. Autronexa stocks genuine surplus and refurbished ABB modules that are tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch. For a part that must match an existing CEXbus slot count — up to 12 units — and a specific controller firmware, a verified surplus unit keeps the configuration consistent without waiting on a factory order. Note the compatibility boundary: this module works only with System 800xA 6.0.3.2 and Compact Control Builder 6.0.0-2 and onwards. Confirm your controller and builder versions before ordering, and contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this CI854B a genuine ABB module or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, including the CI854BK01 article number 3BSE069449R1, before it is listed as genuine surplus.
What condition will the module arrive in?
Units ship in the site default condition, Refurbished, tested against OEM datasheet specifications and functionally verified by our sourcing team. Each package includes the CI854BK01 communication interface and a TP854 baseplate.
How fast can Autronexa ship a CI854B?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; surplus and refurbished units are ready to ship once confirmed.
Does this module work with my AC 800M and 800xA version?
The CI854B is compatible only with System 800xA 6.0.3.2 and Compact Control Builder 6.0.0-2 and onwards. Confirm your controller and builder versions with Autronexa before ordering.
Can two CI854B modules be paired for redundancy?
Yes. Master redundancy uses two CI854B modules, and it can be combined with CPU redundancy and CEXbus redundancy via the BC810. The module also supports line redundancy through its two PROFIBUS ports.
Related & compatible parts
ABB
DO818
Genuine surplus ABB DO818 digital output module for S800 I/O — 32 channels, 24 V d.c., verified condition…
ABB
CI920AS
Genuine surplus ABB CI920AS communication interface for S900 I/O — PROFIBUS DP-V1, ATEX Zone 1, verified and ready…
ABB
SM812
Genuine surplus ABB SM812 safety module for intelligent controller supervision in SIL1-2 and 1oo2 SIL3 architectures. Verified condition.
ABB
AI563
Genuine surplus ABB AI563 analog input module with 4 configurable thermocouple inputs. Verified condition and fast lead times…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
