ABB CI858
DriveBus protocol
Genuine surplus ABB CI858 DriveBus interface for AC 800M — verified, tested, and ready to ship with clear lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3BSE018135R1 |
|---|---|
| Communication Protocol | ABB's DriveBus |
| Transmission Speed | 8 Mbit/s |
| Max Units on CEX Bus | 2 |
| Connector | Optical |
| 24 V Consumption | typ. 200 mA |
| Operating Temperature | +5 to +55 °C (+41 to +131 °F) |
| Protection Class | IP20 according to EN60529, IEC 529 |
| Dimensions (W × H × D) | 59 mm × 185 mm × 127.5 mm |
| Weight (including base) | 700 g (1.5 lbs) |
Description
When a paper machine or rolling mill drive line loses its communication link, every minute of downtime compounds. The ABB CI858 DriveBus communication interface restores that link between ABB drives and the AC 800M controller — and sourcing a genuine surplus unit keeps your line running without OEM lead-time delays. Autronexa supplies verified, refurbished CI858 modules with practical sourcing support.
What This unit Does in an ABB Drive System
This unit is a communication interface unit that connects the AC 800M controller to ABB drives and special I/O units over the DriveBus protocol. It plugs into the CEX-Bus and draws its power from the processor unit, so no separate external supply is needed. The module acts as a master on the bus, transmitting at 8 Mbit/s. One unit supports up to 24 ABB drives; an AC 800M controller can host a maximum of two such modules. When more than one drive is connected, an NDBU branching unit is required to build a logical bus with physical star topology, and branching units can be chained. Hot-swap capability means you can replace the module without shutting down the controller — a practical advantage in continuous-process lines.

Technical Specifications That Matter on the Floor
This unit uses an optical connector, which keeps the communication link immune to electrical noise in drive-heavy environments. Power consumption is typically 200 mA at 24 V, a modest load on the CEX-Bus. Operating temperature ranges from +5 to +55 °C, while storage tolerates -40 to +70 °C. The module carries CE marking, RoHS compliance under DIRECTIVE/2011/65/EU, and marine certificates from ABS, BV, DNV-GL, and LR — relevant if your drives sit in harsh or classified locations. Protection class is IP20, so the module belongs inside a control cabinet. Dimensions are 59 mm wide, 185 mm high, and 127.5 mm deep, with a weight of 700 g including base. Corrosion protection is G3 compliant to ISA 71.04.

Why Genuine Surplus Makes Sense for This Module
ABB’s DriveBus interface is a long-life product, but OEM lead times on spare communication modules can stretch when demand spikes. A verified surplus or refurbished unit gives you a tested alternative: each unit is inspected against OEM datasheet specifications and functionally verified by our sourcing team before it ships. You get the genuine article — not a clone — with clear condition notes and current availability. For maintenance teams supporting sectional drive applications in rolling mills or paper machines, keeping a spare unit on the shelf is practical insurance. Autronexa helps you confirm the exact article number 3BSE018135R1 and any revision details before you commit. Please verify current lifecycle status and availability with Autronexa before ordering.
Selecting the Right DriveBus Interface
Before you order, confirm the module will match your AC 800M controller configuration: check that your application uses DriveBus (not another protocol), verify the number of drives on the bus, and confirm whether an NDBU branching unit is already installed. This unit is a master-only interface, so it is not a drop-in for slave roles. Also check cabinet space against the 59 mm width and 127.5 mm depth. If you are replacing an existing unit, note the article number and any visible revision markings. Autronexa can cross-reference your requirements against our surplus stock and advise on compatibility. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB CI858, or a clone?
Autronexa verifies every CI858 against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units, not grey-market copies.
What condition will the CI858 arrive in?
Our default condition is refurbished: each unit is inspected and functionally verified against OEM specifications before shipping. Contact us for specific condition notes on current stock.
How fast can you ship the CI858?
Lead time depends on current stock. Contact Autronexa for verified availability and the fastest shipping option for your location.
Does the CI858 work with my AC 800M controller?
Yes — the CI858 is designed for the AC 800M controller via the CEX-Bus, supporting up to 24 ABB drives per module and a maximum of two modules per controller.
Is the CI858 still supported by ABB?
Lifecycle status can vary. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
07 KT 96
Genuine surplus ABB 07 KT 96 Advant Controller Basic Unit, verified and ready to ship for Advant-based control…
ABB
PM857K01
Genuine surplus ABB PM857K01 CPU board for AC 800M — SIL3-certified, 96 MHz, 32 MB memory, verified condition…
ABB
C1500000STD
Genuine surplus ABB C1500000STD Commander 150 process controller — verified condition, practical lead times, and sourcing support from…
ABB
CI801
Genuine surplus ABB CI801 PROFIBUS DP-V1 interface — verified condition, faster than OEM lead time, sourcing support from…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…