ABB CI856
Realized
Genuine surplus ABB CI856 S100 I/O interface for AC 800M — verified, tested, and ready to ship with clear lead times.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article Number | 3BSE026055R1 |
|---|---|
| Communication Protocol | ABB's S100 I/O |
| Master or Slave | Master |
| Hot Swap | Yes |
| Max Units on CEX Bus | 12 |
| Connector | Miniribbon (36-pin) |
| 24 V Consumption (typ.) | 120 mA |
| Operating Temperature | 0 to +55 °C (+32 to +131 °F) |
| Protection Class | IP20 according to EN60529, IEC 529 |
| Dimensions (W × H × D) | 59 mm × 185 mm × 127.5 mm |
Description
When an S100 I/O link fails on a running AC 800M system, every hour of downtime adds cost. The ABB CI856 communication interface connects up to five S100 I/O racks to the CEX-Bus, letting you reuse existing field wiring and terminations instead of rewiring entire cabinets. Autronexa supplies genuine surplus and refurbished units, verified against OEM datasheet markings, so you restore communication without paying full OEM list price or waiting on a long factory lead time.
What the CI856 Does in an AC 800M System
This unit is a master interface that mounts on a base plate and connects to the CEX-Bus, drawing its power from the processor unit through that bus. No separate external power supply is needed, which removes one power and wiring cost from your cabinet build. The base plate TP856 carries a ribbon connector to bus extender boards in the S100 I/O racks and provides simple DIN-rail mounting. Each connected rack can hold up to 20 I/O boards, and one interface supports up to five racks. A code-locking device prevents mounting incompatible components, protecting you from a mismatched part that would otherwise stall commissioning.

Cost and Efficiency Advantages of Genuine Surplus
The biggest cost lever with this interface is reuse. It lets you keep the majority of an existing I/O installation, including terminations and field wiring, in ABB Master and Advant OCS installations. That means less new cable, fewer terminations, and shorter shutdowns during migration or repair. Hot swap functionality lets you replace the module without shutting down the rack, reducing production interruption. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so you get a verified part at surplus pricing rather than a grey-market unit with unknown history. For a running line, that combination of lower part cost and faster availability directly reduces total repair cost.

Sourcing Checklist for This unit
Before ordering, confirm the article number matches your system documentation, since This unit family carries more than one article variant. Check that your application uses the S100 I/O protocol and that the CEX-Bus slot count stays within the maximum of 12 units on the bus. Verify the operating environment: the module is rated 0 to +55 °C with IP20 protection, so cabinet airflow and dust control matter. Ask whether you need the TP856 base plate included, because the module alone will not mount without it. Autronexa can cross-reference your existing part number and confirm condition, whether surplus or refurbished, before shipment. Please verify current lifecycle status and availability with Autronexa before ordering.
Frequently asked questions
Is this ABB CI856 a genuine unit or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference before it enters stock. We supply genuine surplus and refurbished ABB components, not grey-market copies.
What condition will the CI856 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — confirm the exact condition with Autronexa when you request a quote.
How fast can Autronexa ship the CI856?
Lead time depends on current stock. Contact Autronexa with your part number for verified condition and current availability; in-stock surplus and refurbished units are ready to ship.
Does the CI856 work with existing ABB Master and Advant OCS wiring?
Yes. The interface is designed to reuse the majority of existing I/O installations, including terminations and field wiring, in ABB Master and Advant OCS systems. It communicates over ABB's S100 I/O protocol as a master.
Is the CI856 still supported by ABB?
Lifecycle status is not stated in our current data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
ABB
SD833
Genuine surplus ABB SD833 power supply: 24 V DC, 10 A, 240 W, DIN-rail, SELV/PELV. Verified condition and…
ABB
V18345-1010221001
Genuine surplus ABB TZIDC-120 valve positioner, 4–20 mA two-wire, IP 65, with analog feedback. Verified condition, ready to…
ABB
CI865
Genuine surplus ABB CI865 module for AC 800M — bridges Satt I/O with hot-swap support. Verified condition, ready…
ABB
AI563
Genuine surplus ABB AI563 analog input module with 4 configurable thermocouple inputs. Verified condition and fast lead times…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
