ABB FENA-21
FENA-01/-11/-21 Ethernet Adapter Dual Port
Genuine ABB FENA-21 dual-port Ethernet adapter for drives — PROFINET IO, EtherNet/IP, Modbus TCP. Verified surplus, ready to ship.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Accessory Type | Ethernet Adapter Dual Port |
|---|---|
| For Use With | Converters and Inverters, ABB Drives |
| Supported Protocols | PROFINET IO, EtherNet/IP, Modbus TCP |
| PROFINET Features | PROFINET IO DP-V1, PROFIdrive profile, ABB drive profile, transparent modes (16-bit and 32-bit words) |
| EtherNet/IP Features | EtherNet/IP server, ODVA AC/DC Drive, ABB drive, Transparent profiles; explicit and implicit messaging |
| Modbus TCP Features | Modbus TCP server, ABB drive profiles, read/write single- and multi-register function codes |
| Protocol Selection | Via drive parameter |
Description
The ABB FENA-21 Ethernet Adapter Dual Port connects converters and inverters to industrial networks via PROFINET IO, EtherNet/IP, or Modbus TCP. Maintenance teams and automation engineers choose genuine surplus or refurbished units to restore drive communications quickly without OEM lead times or full list price.
What This Adapter Does in a Drive System
The FENA-21 is a two-port Ethernet adapter that slots into ABB drives, giving them a network presence. Protocol selection happens inside the drive through a single parameter — no hardware swaps. For PROFINET, it supports PROFINET IO DP-V1 with the PROFIdrive profile or ABB drive profile, plus transparent modes for 16-bit and 32-bit words. As an EtherNet/IP server, it handles ODVA AC/DC Drive, ABB drive, and Transparent profiles, with explicit messaging for per-attribute settings and implicit messaging using input and output instances. In Modbus TCP mode, it acts as a server supporting ABB drive profiles and generic read/write single- and multi-register function codes. This flexibility means one adapter part can serve multiple network standards, reducing spares complexity across a plant.

Why Genuine Surplus Makes Sense Here
Network adapters like this are often the first component to fail when a drive goes offline, and OEM lead times can stretch weeks. Autronexa stocks verified surplus and refurbished unit units that are tested against OEM datasheet specifications and functionally verified by our sourcing team. You get a genuine ABB adapter — not a clone — with clear condition notes and current availability. For maintenance managers, that means faster restoration of PROFINET, EtherNet/IP, or Modbus TCP communications without paying new-list pricing. Because the adapter is parameter-configured, a refurbished unit behaves identically to a new one once installed and set up.
Sourcing Checklist for This Adapter
Before ordering, confirm the exact adapter variant your drive requires — FENA-01, FENA-11, and unit share the same family but may differ in port count or protocol support. Verify that your drive firmware accepts the adapter and that the desired protocol (PROFINET IO, EtherNet/IP, or Modbus TCP) is enabled. Check condition: surplus units are typically unused old stock, while refurbished units have been tested and verified. Ask for the specific condition grade and any included accessories. Autronexa provides hands-on sourcing help across ABB and other automation brands, so you can confirm compatibility before shipment. Please verify current lifecycle status and availability with Autronexa before ordering.
Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB FENA-21 adapter, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished ABB adapters, not grey-market copies.
What condition will the FENA-21 arrive in?
Our default condition is refurbished: tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units may also be available — contact us for current condition grades.
How fast can you ship the FENA-21?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; we aim to ship verified units as quickly as possible.
Does this adapter work with PROFINET, EtherNet/IP, and Modbus TCP?
Yes. The FENA-21 supports all three protocols, selected via a drive parameter. It supports PROFINET IO DP-V1, EtherNet/IP server profiles, and Modbus TCP server function codes as described in the datasheet.
Is the FENA-21 still supported by ABB?
Lifecycle status is not stated in our data. Contact Autronexa to verify OEM support status and availability before ordering.
Related & compatible parts
ABB
AO845A
Genuine surplus ABB AO845A analog output module: 8 channels, 4-20 mA, HART pass-through, redundancy-ready. Verified condition and sourcing…
ABB
CI858
Genuine surplus ABB CI858 DriveBus interface for AC 800M — verified, tested, and ready to ship with clear…
ABB
DO828
Genuine surplus ABB DO828 relay driver: 16 isolated channels, 125V DC/250V AC, 2A, S800 I/O. Verified condition and…
ABB
AI563
Genuine surplus ABB AI563 analog input module with 4 configurable thermocouple inputs. Verified condition and fast lead times…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
