ABB TU830V1
Extended Module Termination Unit
Genuine surplus ABB TU830V1 termination unit — 16 channels, DIN rail mount, tested and ready for your S800 I/O system.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Channels | 16 |
|---|---|
| Maximum voltage | 50 V |
| Max current per channel | 2 A |
| Max current process connection | 5 A |
| Acceptable wire sizes (solid) | 0.2 – 4 mm² |
| Acceptable wire sizes (stranded) | 0.2 – 2.5 mm², 24 – 12 AWG |
| Recommended torque | 0.5 – 0.6 Nm |
| Stripping length | 7 mm |
| Operating temperature | 0 to +55 °C |
| Protection class | IP20 |
Description
When field wiring needs a reliable interface to S800 I/O modules, the ABB TU830V1 Extended Module Termination Unit delivers 16 channels of passive connectivity with integrated ModuleBus distribution. Maintenance teams choose genuine surplus or refurbished units to restore system integrity without OEM lead-time delays. Autronexa supplies verified, tested units ready for installation.
What This Termination Unit Does in Your System
The TU830V1 is a passive termination unit that connects field wiring to I/O modules and carries part of the ModuleBus. It supports up to 16 I/O channels, each with two I/O connections and one ZP connection, and provides two process voltage connections that can be individually isolated. Each group includes a 6.3 A fuse, and the maximum rated voltage is 50 V with a maximum current of 2 A per channel. The unit distributes the ModuleBus to the next MTU and generates the correct address for the I/O module by shifting outgoing position signals. Mechanical keying prevents insertion of the wrong I/O module, and a latching device secures the unit to DIN rail for grounding. This unit works with a wide range of ABB I/O modules including AI810, AO810, DI810, DO810, and DP820 series.

Technical Specs That Matter for Maintenance
Three specifications stand out for serviceability. First, acceptable wire sizes: solid conductors from 0.2 to 4 mm² and stranded conductors from 0.2 to 2.5 mm² (24–12 AWG), with a recommended torque of 0.5–0.6 Nm and a stripping length of 7 mm — these values ensure secure, repeatable terminations during field wiring. Second, corrosion protection rated ISA-S71.04: G3, which suits many industrial environments where airborne contaminants are a concern. Third, RoHS compliance to EN 50581:2012 confirms the unit meets current material restrictions. This unit also carries CE marking and is rated for operating temperatures from 0 to +55 °C, with approvals issued for +5 to +55 °C. Its IP20 protection class is appropriate for cabinet-mounted installations. For maintenance engineers, the keying and latching features reduce the risk of misconnection during module swaps, and the fused process voltage groups simplify troubleshooting.
Surplus Advantage: Why Refurbished Makes Sense Here
As a passive termination unit, This unit has no active electronics that wear out — its reliability hinges on mechanical integrity and connection quality. A professionally refurbished unit is tested against OEM datasheet specifications and functionally verified by our sourcing team, so you get a part that meets original performance without paying OEM list price or waiting for new production. Autronexa specializes in genuine surplus and refurbished automation components, and this termination unit is a regularly requested item. Because This unit is used across many S800 I/O configurations, availability from surplus channels is often better than OEM lead times. When you need to restore a system quickly, a verified refurbished unit can be the practical choice. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB TU830V1, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference. We supply only genuine surplus or refurbished ABB components, never grey-market clones.
What condition will the TU830V1 arrive in?
Our default condition is refurbished: tested against OEM specifications and functionally verified. We can also supply surplus units in original condition — contact us for current stock and grading.
How fast can you ship the TU830V1?
Lead time varies with stock. Contact Autronexa for current availability and lead time — we prioritize urgent maintenance requests.
Does the TU830V1 work with my existing S800 I/O modules?
The TU830V1 is compatible with a wide range of ABB I/O modules including AI810, AO810, DI810, DO810, and DP820 series. Check your module list against the compatibility data or contact us for confirmation.
Is the TU830V1 still supported by ABB?
Lifecycle status can vary. Please verify current lifecycle status and availability with Autronexa before ordering — we can confirm OEM support status and offer suitable alternatives if needed.
Related & compatible parts
ABB
PM867K02
Genuine surplus ABB PM867K02 Redundant Processor Unit HI (3BSE081638R1) — SIL3-certified, verified condition, ready to ship from Autronexa.
ABB
TK811V050
Genuine ABB TK811V050 5m duplex POF cable for ModuleBus — verified surplus stock with clear lead times from…
ABB
07AI91
Genuine surplus ABB 07AI91 analog input module: 8 configurable channels for temperature or voltage on the CS31 system…
ABB
SD833
Genuine surplus ABB SD833 power supply: 24 V DC, 10 A, 240 W, DIN-rail, SELV/PELV. Verified condition and…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…