ABB 07AI91
Analog Input Module 07 AI 91
Genuine surplus ABB 07AI91 analog input module: 8 configurable channels for temperature or voltage on the CS31 system bus, verified before dispatch.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Number of analog input channels | 8 (each configurable in pairs) |
|---|---|
| Rated supply voltage | 24 V DC |
| Max. current consumption | max. 0.15 A |
| Max. power dissipation | max. 3 W |
| Permissible temperature range during operation | 0...55 °C |
| Voltage measuring ranges | +/- 10 V, +/- 5 V, +/- 500 mV, +/- 50 mV |
| Resolution | 12 bit + sign |
| Dimensions (W x H x D) | 120 x 140 x 85 mm |
| Weight | 450 g |
Description
The ABB 07AI91 analog input module gives CS31 system bus installations eight configurable analog channels for temperature sensors or voltage signals, and Autronexa supplies it as a verified genuine surplus unit rather than a grey-market substitute. Maintenance and procurement teams choose refurbished stock here because the module is a direct drop-in for existing CS31 racks, so no re-engineering cost is added to the repair budget.
What the 07 AI 91 Does in a CS31 System
The module operates as a remote analog input unit on the CS31 system bus, and each of its eight channels uses 16 bits in the word input range. Channels are configured in pairs through DIL switches under the right housing cover, which also set the module address — one group number per unit. That pairing scheme matters for cost: a failing channel pair can be reconfigured around without scrapping the whole module, and spare capacity on partially used cards can be brought online later instead of buying additional hardware. Input ranges cover ± 10 V, ± 5 V, ± 500 mV and ± 50 mV, plus 4…20 mA through an external 250 Ω resistor. Pt100 and Pt1000 sensors are supported with linearization across -50…400 °C, and thermocouples types J, K and S are linearized in the module, which removes the cost of separate temperature transmitters on each loop. Only electrically isolated sensors may be used.

Why Genuine Surplus Fits This Module
Analog input cards sit at the point where measurement accuracy turns directly into process cost — a drifting channel skews control decisions and quietly inflates energy or reagent consumption. Autronexa’s refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team, so the ± 0.5 % of full scale total error on voltage inputs and the 12-bit-plus-sign resolution are confirmed before dispatch, not assumed. Surplus and refurbished stock also shortens the wait compared with an OEM backorder, keeping a CS31 rack productive while a longer-term replacement is planned. Because the CS31 bus interface is electrically isolated from the rest of the unit, a replacement module does not put the bus segment at risk during commissioning.

Specs That Affect Operating Cost
Power and thermal figures shape the enclosure budget. The unit runs on 24 V DC with maximum current consumption of 0.15 A and maximum power dissipation of 3 W, so it adds little load to an existing supply and rarely forces a cabinet cooling upgrade. The permissible operating range of 0…55 °C suits most control rooms without extra climate control. Line frequency suppression is configurable for 50 Hz, 60 Hz or none; with 50/60 Hz suppression the typical update period is 100 ms per channel, falling to about 30 ms with suppression off — a trade-off worth weighing when fast loops share the card with noisy supplies. Unused channels must be bridged, and the module mounts on a 15 mm DIN rail or with four M4 screws at 120 x 140 x 85 mm and 450 g.
Sourcing Checklist Before You Order
Confirm the exact module address setting your rack expects, since the coding switch position is part of the configuration and not the part number. Check whether your loops need the external 250 Ω shunt for current input, and verify sensor isolation before connecting. Ask for the condition grade in writing — surplus and refurbished units differ, and Autronexa states the grade per unit. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB 07AI91, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it enters stock. The module is supplied as genuine surplus or professionally refurbished, never as a grey-market copy.
What condition will the module arrive in?
Units ship in the condition stated at the time of order, with the site default being Refurbished — tested against OEM datasheet specifications and functionally verified by our sourcing team. Request the condition grade in writing with your quote.
How fast can you ship the 07AI91?
Lead time depends on current stock at the time of your request. Contact Autronexa with your part number for verified condition and current availability, and we will confirm the dispatch date before you commit.
Can the module handle both temperature sensors and voltage signals?
Yes. Channels are configured in pairs for ± 10 V, ± 5 V, ± 500 mV or ± 50 mV inputs, 4...20 mA with an external 250 Ω resistor, Pt100/Pt1000 sensors, or thermocouples types J, K and S with linearization. Only electrically isolated sensors may be used.
Is the 07 AI 91 still supported by ABB?
Lifecycle status is not stated in our current documentation for this module. Contact Autronexa to verify OEM support status and availability before you plan a long-term spares strategy.
Related & compatible parts
ABB
TU805
Genuine surplus ABB TU805 kit — 10 terminal units for DI801/DO801, 16 channels, 50 V, verified condition and…
ABB
07 KT 94
Genuine surplus ABB 07 KT 94 Advant Controller with 24 DI, 16 DO, 8 AI/O, 4 AO —…
ABB
ACS880-01-430A-3
Genuine surplus ABB ACS880-01-430A-3 drive, 250 kW / 430 A, verified condition and ready for sourcing.
ABB
V18345-2020521001
Genuine surplus ABB TZIDC positioner with HART, IP 65 aluminium case, and double-acting fail-freeze output — verified and…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…