ABB TU891
Compact installations
Genuine surplus ABB TU891 MTU for compact I/O: 8 channels, 24 V, 27 gray terminals, mechanical keying for I.S. modules.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Article number | 3BSC840157R1 |
|---|---|
| Channels | 8 |
| Voltage | 24 V |
| Maximum current per I/O channel | 2 A |
| Process connections | 27 gray terminals |
| Wire sizes, process connector | Solid 0.2 - 4 mm²; stranded 0.2 - 2.5 mm², 24 - 12 AWG |
| Wire sizes, power supply connector | 0.25 - 2.5 mm², 24 - 14 AWG |
| Recommended torque | 0.5 - 0.6 Nm |
| Operating temperature | 0 to +55 °C (+32 to +131 °F) |
| Protection class | IP20 according to IEC 60529 |
Description
The ABB TU891 is a compact Module Termination Unit (MTU) for 8-channel I/O in intrinsic safety applications, used with AI890, AI893, AI895, AO890, AO895, DI890 and DO890 modules. Maintenance and procurement teams choose genuine surplus or refurbished units here because this MTU is a mechanical and wiring interface — its condition directly affects signal integrity and module keying, so verified authenticity matters more than a sealed box.
What the TU891 Does in a Compact I/O System
The MTU sits between field wiring and the I/O module. It carries 27 gray terminals for field signals and process power connections, distributes the ModuleBus to the I/O module and to the next MTU, and generates the correct address for the I/O module by shifting outgoing position signals to the next unit. Two mechanical keys configure the unit for different types of I.S. I/O modules; this is a mechanical setting only and does not affect MTU or I/O module functionality. The keys on this unit are of the opposite gender to those on other MTU types and mate only with IS I/O modules — a practical safeguard against inserting the wrong module. A latching device secures the unit to DIN rail, and mounting is horizontal.

Technical Specifications Buyers Should Check
The headline electrical rating is 24 V, with a maximum current of 2 A per I/O channel; the design of the I/O modules constrains these values for their certified application. Wiring capacity differs by connector: the process connector accepts solid 0.2 – 4 mm² and stranded 0.2 – 2.5 mm², 24 – 12 AWG, while the power supply connector accepts 0.25 – 2.5 mm², 24 – 14 AWG. Recommended torque is 0.5 – 0.6 Nm on both. The dielectric test voltage is 500 V a.c. Environmental limits are 0 to +55 °C operating (storage -40 to +70 °C), 5 to 95 % RH non-condensing, pollution degree 2 per IEC 60664-1, and corrosion protection to ISA-S71.04: G3. The housing is IP20 per IEC 60529 and measures 64 mm wide including connector, 58 mm deep, 194 mm high including latch, at 0.17 kg.

Surplus Advantage and Sourcing Guidance
For a termination unit, the risk in the secondary market is not cosmetic wear — it is missing keys, damaged terminals, or a unit pulled from a different MTU family. Autronexa sources genuine surplus and refurbished ABB units and verifies markings and part-number cross-reference before listing. Refurbished stock is tested against OEM datasheet specifications and functionally verified by our sourcing team, which typically shortens the wait compared with OEM lead time on compact I/O accessories. Before ordering, confirm the exact article number 3BSC840157R1, that your application uses single (not redundant) I/O, and that your module is one of the I.S. types listed above. Check that both mechanical keys are present and of the correct gender for your module. Please verify current lifecycle status and availability with Autronexa before ordering. Contact Autronexa with your part number for verified condition and current availability.
Frequently asked questions
Is this a genuine ABB TU891, or a clone?
Autronexa verifies each unit against OEM datasheet markings and part-number cross-reference, including the article number 3BSC840157R1, before it is listed as genuine surplus or refurbished stock.
What condition will the TU891 arrive in?
Units are supplied in the site default condition, Refurbished, unless the listing states otherwise. Refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team.
How fast can you ship the TU891?
Lead time depends on current stock. Contact Autronexa for current lead time and availability; verified surplus and refurbished units are typically ready to ship faster than OEM backorder cycles.
Which I/O modules does this MTU work with?
The TU891 is intended for intrinsic safety applications with AI890, AI893, AI895, AO890, AO895, DI890 and DO890 modules. Its mechanical keys are of the opposite gender to other MTU types and mate only with IS I/O modules.
Is the TU891 still supported by ABB?
Lifecycle status is not stated in our source data. Contact Autronexa to verify OEM support status and current availability before ordering.
Related & compatible parts
ABB
DP840
Genuine surplus ABB DP840 8-channel pulse counter module with 20 kHz frequency measurement and advanced diagnostics — verified…
ABB
ACS880-01-156A-5
Genuine surplus ABB ACS880-01-156A-5 wall-mounted drive, 90 kW, 156 A — verified condition, tested, and ready to ship…
ABB
SD831
Genuine surplus ABB SD831 power supply: 24 V DC, 3 A, 72 W, DIN-rail mount. Verified condition, faster…
ABB
07 DI 93-I
Genuine surplus ABB 07 DI 93-I input unit for Advant Controller 31 — 16 channels, IP67, verified condition…
News & guides for ABB
ABB Buys Rotork: What the $5.5B Deal Means for Actuator Spares
ABB's $5.5 billion cash offer for Rotork, part-funded by the SoftBank robotics divestment, moves the group deeper into mission-critical flow…
Emerson Q4 FY2026: LNG Sales Up 68%, Semiconductor Up 43%, Software ACV at $1.7B
Emerson closed FY2026 with 7% sales growth and 14% underlying order growth. We verify what the 68% LNG, 43% semiconductor,…
Siemens MIS: A Specification Walkthrough for the Pre-Engineered Microgrid Switchboard
Siemens MIS published ratings, one-line interface responsibilities, UL 891 and UL 3141 scope, and what factory testing does and does…
Murata’s SWL RF Test Connector: What the 40% Claim Actually Covers
Murata Manufacturing announced on 29 October 2026 that its SWL series of RF and microwave coaxial connectors with a built-in…
Nexans 700 VDC Microgrid: What Changes for Factories and Spares
Nexans has switched part of its own AmpaCity global innovation hub in Lyon, France, onto a 700 V direct-current main distribution…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…