Bently Nevada Power Supplies

Bently Nevada 3300/12-01-20-00

AC Power Supply Module

Manufacturer: Bently Nevada Part Number: 3300/12-01-20-00

The Bently Nevada 3300/12 is the power supply module for the 3300 monitoring system, providing rack power and programmable transducer excitation.

  • New Surplus
  • Available on request
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

Ships within 7 business days

Technical specifications

Manufacturer Bently Nevada
Product No. 3300/12-01-20-00
Product Type AC Power Supply
Inputs / Power 95 to 125 Vac, single phase, 50 to 60 Hz, at 1.0 A maximum; or 190 to 250 Vac, single phase, 50 to 60 Hz, at 0.5 A maximum. Field changeable via soldered jumper and replacement of external fuse.
Surge at Powerup 26 A peak, or 12 A rms, for one cycle
Fuse Rating 1.5 A slow blow (95 to 125 Vac); 0.75 A slow blow (190 to 250 Vac)
Transducer Power (internal to rack) User-programmable -24 Vdc, +0%, -2.5%; or -18 Vdc, +1%, -2%; transducer voltages are overload protected, per channel, on the individual monitor circuit boards
OK Relay Location Behind the Power Supply, at the Power Supply Input Module
OK Relay Type Single-pole, double-throw (SPDT)
Sealing Hermetically-sealed
Contact Ratings (resistive load) 5 A at 28 Vdc; 5 A at 120 Vac, 50/60 Hz; 3 A at 220 Vac, 50/60 Hz
Ratings for Systems Requiring Agency Approval 5 A at 28 Vdc; 5 A at 120 Vac, 50/60 Hz (30 Vac for ATEX)
Contact Life 10,000 cycles minimum at rated load
Operation Normally energized
Operating Temperature 0 °C to +65 °C (+32 °F to +150 °F)
Storage Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Relative Humidity To 95%, noncondensing
Input Voltage Option 01 = 95-125 Vac 50/60 Hz (field-changeable)
Power Input Module Option 20 = Standard
Agency Approval Option 00 = Not Required

Description

The Bently Nevada Bently Nevada 3300/12-01-20-00 AC Power Supply Module – Datasheet, Specs & In Stock is a ac power supply supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: input voltage option 01 = 95-125 Vac 50/60 Hz (field-changeable); operating temperature 0 °C to +65 °C (+32 °F to +150 °F)

Electrical Ratings

Inputs / Power is 95 to 125 Vac, single phase, 50 to 60 Hz, at 1.0 A maximum; or 190 to 250 Vac, single phase, 50 to 60 Hz, at 0.5 A maximum. Field changeable via soldered jumper and replacement of external fuse.. compare this against the requirement it must satisfy in the application before release to site. Surge at Powerup is 26 A peak, or 12 A rms, for one cycle. this describes how the part behaves during supply disturbances, which matters where an outage must not cause an unplanned trip. Transducer Power (internal to rack) is User-programmable -24 Vdc, +0%, -2.5%; or -18 Vdc, +1%, -2%; transducer voltages are overload protected, per channel, on the individual monitor circuit boards. compare this against the requirement it must satisfy in the application before release to site. Input Voltage Option is 01 = 95-125 Vac 50/60 Hz (field-changeable). match this against the supply available at the installation site, including any tolerance on the incoming feed. Power Input Module Option is 20 = Standard. order by the exact option code shown; variants of the same base number are not interchangeable.

Environmental & Compliance Ratings

Ratings for Systems Requiring Agency Approval is 5 A at 28 Vdc; 5 A at 120 Vac, 50/60 Hz (30 Vac for ATEX). use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Operating Temperature is 0 °C to +65 °C (+32 °F to +150 °F). check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Storage Temperature is -40 °C to +85 °C (-40 °F to +185 °F). observe this figure during transport and warehouse storage, which are not the same condition as operation. Relative Humidity is To 95%, noncondensing. maintain the stated humidity range in the cabinet; condensation is the usual cause of failure in equipment installed in humid plant rooms. Agency Approval Option is 00 = Not Required. use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file.

Signal & Communication

OK Relay Type is Single-pole, double-throw (SPDT). check the switching capacity against the circuit it will interrupt, since relay contacts are commonly the limiting element in an installation. Contact Ratings (resistive load) is 5 A at 28 Vdc; 5 A at 120 Vac, 50/60 Hz; 3 A at 220 Vac, 50/60 Hz. check the switching capacity against the circuit it will interrupt, since relay contacts are commonly the limiting element in an installation. Contact Life is 10,000 cycles minimum at rated load. check the switching capacity against the circuit it will interrupt, since relay contacts are commonly the limiting element in an installation.

Additional Verified Data

Product No. is 3300/12-01-20-00. Fuse Rating is 1.5 A slow blow (95 to 125 Vac); 0.75 A slow blow (190 to 250 Vac). Sealing is Hermetically-sealed. Operation is Normally energized.

Models in This Series

Autronexa currently lists this ac power supply as the only model in its entry. Cross-reference requests for equivalent or superseded part numbers are handled on request.

Confirming the Correct Variant Before Ordering

Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the input voltage option available at the installation site is 01 = 95-125 Vac 50/60 Hz (field-changeable), which is the documented requirement for this model.

Request a Quote

Bently Nevada supplies the Bently Nevada 3300/12-01-20-00 AC Power Supply Module – Datasheet, Specs & In Stock as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.

Frequently asked questions

What does the Bently Nevada 3300/12 Power Supply do?

It delivers reliable, regulated dc power for up to 12 monitors and their associated transducers in a 3300 rack. A second power supply in the same rack is never required.

What input voltage does the 3300/12 accept?

It converts 95 to 125 Vac single-phase 50/60 Hz at 1.0 A maximum, or 190 to 250 Vac single-phase 50/60 Hz at 0.5 A maximum. The input is field-changeable via a soldered jumper and external fuse replacement.

Where is the 3300/12 installed in the rack?

It is installed in the left-most location (position 1) of a 3300 rack and is equipped with a line-noise filter as standard.

What are the environmental limits of the 3300/12?

Operating temperature is 0 deg C to +65 deg C (+32 deg F to +150 deg F) and storage temperature is -40 deg C to +85 deg C. Humidity is up to 95%, non-condensing.

What is the OK relay rating on the 3300/12?

The OK relay is single-pole double-throw (SPDT), hermetically sealed, rated 5 A at 28 Vdc / 5 A at 120 Vac / 3 A at 220 Vac (resistive load), with a minimum contact life of 10,000 cycles and normally energized operation.

Is the 3300/12 available with agency approvals?

Yes. Versions are offered for CSA/NRTL/C and ATEX/IECEx/CSA (Class 1, Zone 2) where required; the standard unit ships with no agency approval.

What input voltage does the 3300/12-01-20-00 use?

The Bently Nevada 3300/12-01-20-00 operates at 01 = 95-125 Vac 50/60 Hz (field-changeable). Verify the exact range and any hazardous-area limits against the product label before installation, because input requirements vary by ordered variant.

What is the operating temperature range of the 3300/12-01-20-00?

The Bently Nevada 3300/12-01-20-00 operating temperature is listed as 0 °C to +65 °C (+32 °F to +150 °F). Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.

What is the 3300/12-01-20-00 and what is it used for?

The Bently Nevada 3300/12-01-20-00 is a AC Power Supply device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.

What supply voltage does the Bently Nevada 3300/12-01-20-00 AC Power Supply Module - Datasheet, Specs & In Stock need?

The manufacturer documentation lists input voltage option 01 = 95-125 Vac 50/60 Hz (field-changeable). for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.

What is the operating temperature range of the Bently Nevada 3300/12-01-20-00 AC Power Supply Module - Datasheet, Specs & In Stock?

The documented operating range is 0 °C to +65 °C (+32 °F to +150 °F).. Check that the enclosure temperature at the planned mounting location stays inside this band during the hottest period of the operating year.

Related & compatible parts

Bently Nevada

106769-01

Genuine Bently Nevada 106769-01 interconnect cable, 1 ft (0.3 m), 0.5 kg. Verified surplus stock for reliable transducer-to-monitor…

In Stock

Bently Nevada · 31000 / 32000 Series

31000-28-10-00-017-00-02

Bently Nevada 31000-28-10-00-017-00-02 Proximity Probe Housing. Sulfide (PPS) thermoplastic: containing conductive fibers.

Available on request

Bently Nevada

330876-01-50-00-CN

Bently Nevada 330876-01-50-00-CN Proximity Probes & Sensors. lengths: 1, 5 or 9 meters; Agency Approval: Country Specific.

Available on request

Bently Nevada · 3500/40M

135489-04

Bently Nevada 135489-04 Proximitor I/O Module. Relative Humidity: 95 %, noncondensing; Lifecycle: Current.

Available on request

News & guides for Bently Nevada

View all articles

Request a quote for this part

Part number: 3300/12-01-20-00

We reply within one business day.

3300/12-01-20-00 Quote reply within 1 business day