Bently Nevada I/O & Function Modules

Bently Nevada 3500/60-01-00

Temperature Monitor Module

Manufacturer: Bently Nevada Part Number: 3500/60-01-00

The Bently Nevada 3500/60 is a Temperature Monitor module for the 3500 system, reading up to six RTD or thermocouple inputs for machine thermal protection.

  • New Surplus
  • Available on request
Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

Ships within 7 business days

Technical specifications

Manufacturer Bently Nevada
Product No. 3500/60-01-00
Product Type 3500/60 Temperature Module
Signal Accepts from 1 to 6 RTD or TC transducer signals
Input Impedance 10 MΩ for each lead input
Power Consumption Nominal consumption of 7 watts (3500/60)
Type E TC -100 °C to +1000 °C (-148 °F to +1832 °F)
Type J TC -18 °C to +760 °C (+0 °F to +1400 °F)
Type K TC -18 °C to +1370 °C (+0 °F to +2498 °F)
Type T TC -160 °C to +400 °C (-256 °F to +752 °F)
100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00385) -200 °C to +850 °C (-328 °F to +1562 °F); with external barriers -50 °C to +850 °C (-122 °F to +1562 °F)
100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00392) -200 °C to +700 °C (-328 °F to +1292 °F); with external barriers -50 °C to +260 °C (-122 °F to +1292 °F)
120Ω 3-wire & 4-wire nickel RTD -80 °C to +260 °C (-112 °F to +500 °F); with external barriers -50 °C to +260 °C (-122 °F to +500 °F)
10Ω 3-wire & 4-wire copper RTD -100 °C to +260 °C (-148 °F to +500 °F); with external barriers -50 °C to +260 °C (-122 °F to +500 °F)
OK LED Indicates when the Temperature Monitor is operating properly
TX/RX LED Indicates that the Temperature Monitor is communicating with other modules in the 3500 rack
Bypass LED Indicates when the Temperature Monitor is in Bypass Mode
RTD Current Source Value 925 ±15 µA @ 25 °C per transducer (single supply for the 4-wire RTD and two supplies for the 3-wire)
Recorder Output +4 to +20 mA, proportional to monitor full-scale; individual recorder values per channel; monitor operation unaffected by short circuits on recorder outputs
Operating Temperature -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules; 0 °C to +65 °C (32 °F to +150 °F) with Internal Barrier I/O Modules (Internal Termination)
Storage Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Monitor Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
Monitor Module Weight 0.91 kg (2.0 lb)
I/O Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
I/O Module Weight 0.45 kg (1.0 lb)
Rack Space Requirements Monitor Module: 1 full-height front slot. I/O Modules: 1 full-height rear slot.
Alarm Time Delays Alert: 1 to 60 seconds in 1 second intervals. Danger: 1 to 60 seconds in 0.5 second intervals
I/O Module Type 01 = RTD/TC Non-isolated I/O Module, Internal Terminations
Agency Approval Option 00 = None

Description

The Bently Nevada Bently Nevada 3500/60-01-00 Temperature Monitor Module – Datasheet, Specs & In Stock is a 3500/60 temperature module supplied for replacement and new-build use in industrial control installations. Every rating below is taken from the manufacturer documentation for this part number. Headline figures: power consumption Nominal consumption of 7 watts (3500/60); monitor module weight 0.91 kg (2.0 lb); operating temperature -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules; 0 °C to +65 °C (32 °F to +150 °F) with Internal Barrier I/O Modules (Internal Termination)

Electrical Ratings

Input Impedance is 10 MΩ for each lead input. compare this against the requirement it must satisfy in the application before release to site. Power Consumption is Nominal consumption of 7 watts (3500/60). size the power supply and the rack load around this figure; it is the draw the part places on the supply it is installed in. RTD Current Source Value is 925 ±15 µA @ 25 °C per transducer (single supply for the 4-wire RTD and two supplies for the 3-wire). confirm the field wiring and the load presented to this input stay inside this figure, since exceeding it is the common cause of premature contact failure. Recorder Output is +4 to +20 mA, proportional to monitor full-scale; individual recorder values per channel; monitor operation unaffected by short circuits on recorder outputs. order by the exact option code shown; variants of the same base number are not interchangeable.

Mechanical & Dimensional Data

Monitor Module Dimensions (H x W x D) is 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in). take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. Monitor Module Weight is 0.91 kg (2.0 lb). factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required. I/O Module Dimensions (H x W x D) is 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in). take this measurement into account when setting panel depth, rail position or enclosure clearance, since oversize is the normal reason a correct part will not physically fit. I/O Module Weight is 0.45 kg (1.0 lb). factor this into lifting, rail-loading and shipping decisions; it is also the figure to quote when a handling study is required.

Environmental & Compliance Ratings

Operating Temperature is -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules; 0 °C to +65 °C (32 °F to +150 °F) with Internal Barrier I/O Modules (Internal Termination). check the enclosure temperature at the planned mounting location stays inside this band during the hottest operating period. Storage Temperature is -40 °C to +85 °C (-40 °F to +185 °F). observe this figure during transport and warehouse storage, which are not the same condition as operation. Rack Space Requirements is Monitor Module: 1 full-height front slot. I/O Modules: 1 full-height rear slot.. use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file. Agency Approval Option is 00 = None. use this to confirm the part is acceptable in the classified area of the installation, and to support the documentation in the plant safety file.

Signal & Communication

Signal is Accepts from 1 to 6 RTD or TC transducer signals. this defines what the part reads or drives; confirm it matches the transducer or signal source wired to it. Alarm Time Delays is Alert: 1 to 60 seconds in 1 second intervals. Danger: 1 to 60 seconds in 0.5 second intervals. check the switching capacity against the circuit it will interrupt, since relay contacts are commonly the limiting element in an installation.

Additional Verified Data

Product No. is 3500/60-01-00. Type E TC is -100 °C to +1000 °C (-148 °F to +1832 °F). Type J TC is -18 °C to +760 °C (+0 °F to +1400 °F). Type K TC is -18 °C to +1370 °C (+0 °F to +2498 °F). Type T TC is -160 °C to +400 °C (-256 °F to +752 °F). 100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00385) is -200 °C to +850 °C (-328 °F to +1562 °F); with external barriers -50 °C to +850 °C (-122 °F to +1562 °F). 100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00392) is -200 °C to +700 °C (-328 °F to +1292 °F); with external barriers -50 °C to +260 °C (-122 °F to +1292 °F). 120Ω 3-wire & 4-wire nickel RTD is -80 °C to +260 °C (-112 °F to +500 °F); with external barriers -50 °C to +260 °C (-122 °F to +500 °F). 10Ω 3-wire & 4-wire copper RTD is -100 °C to +260 °C (-148 °F to +500 °F); with external barriers -50 °C to +260 °C (-122 °F to +500 °F). TX/RX LED is Indicates that the Temperature Monitor is communicating with other modules in the 3500 rack. I/O Module Type is 01 = RTD/TC Non-isolated I/O Module, Internal Terminations.

Models in This Series

Autronexa lists 2 other models in the same 3500/60 temperature module entry, and they share this datasheet. Use them to identify the variant that matches the equipment on site: Bently Nevada 3500/60-01-02 Temperature Monitor Module – Datasheet, Specs & In Stock, Bently Nevada 3500/60-01-01 Temperature Monitor Module – Datasheet, Specs & In Stock.

Confirming the Correct Variant Before Ordering

Read the part number marked on the unit being replaced and compare it character by character with the ordering code above, including any option suffix. Check the values in the technical specification table of this page against the nameplate on the existing unit rather than against a previous purchase record. Confirm the power consumption available at the installation site is Nominal consumption of 7 watts (3500/60), which is the documented requirement for this model.

Request a Quote

Bently Nevada supplies the Bently Nevada 3500/60-01-00 Temperature Monitor Module – Datasheet, Specs & In Stock as a quote-based item. Send the part number, quantity and destination for current stock, lead time and pricing; no fixed price is published for this part.

Frequently asked questions

What does the Bently Nevada 3500/60 do?

The 3500/60 Temperature Monitor accepts 1 to 6 RTD or thermocouple transducer signals and provides temperature monitoring within a 3500 machinery-protection rack.

What transducer types does the 3500/60 support?

It supports RTDs (platinum, nickel, copper) and thermocouples (Type E, J, K, T), with an input impedance of 10 M ohm per lead.

What is the power consumption of the 3500/60?

Nominal consumption is 7 watts.

What are the 3500/60 dimensions and weight?

The monitor module is 241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in), 0.91 kg. The I/O module is 241.3 x 24.4 x 99.1 mm, 0.45 kg.

What are the operating limits of the 3500/60?

Operating temperature is -30 deg C to +65 deg C with internal/external termination I/O, or 0 deg C to +65 deg C with internal-barrier I/O. Storage is -40 deg C to +85 deg C.

What agency approvals are available for the 3500/60?

Options include none, CSA/NRTL/C (Class 1, Div 2) and ATEX/IECEx/CSA (Class 1, Zone 2).

What is the operating temperature range of the 3500/60-01-00?

The Bently Nevada 3500/60-01-00 operating temperature is listed as -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules; 0 °C to +65 °C (32 °F to +150 °F) with Internal Barrier I/O Modules (Internal Termination). Stay within the documented band during operation; storage limits may differ. Elevated ambient conditions can reduce the continuous current or power rating of the module.

What are the dimensions and weight of the 3500/60-01-00?

The Bently Nevada 3500/60-01-00 measures 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) and weighs 0.91 kg (2.0 lb). Confirm clearance and rack or panel space before ordering.

What is the 3500/60-01-00 and what is it used for?

The Bently Nevada 3500/60-01-00 is a 3500/60 Temperature Module device. It is used in industrial control and automation systems where a verified part number and specification match are required for replacement or new design.

What supply voltage does the Bently Nevada 3500/60-01-00 Temperature Monitor Module - Datasheet, Specs & In Stock need?

The manufacturer documentation lists power consumption Nominal consumption of 7 watts (3500/60). for this model. Confirm the supply at the installation site matches, including any tolerance on the incoming feed, before the part is ordered.

What is the operating temperature range of the Bently Nevada 3500/60-01-00 Temperature Monitor Module - Datasheet, Specs & In Stock?

The documented operating range is -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules; 0 °C to +65 °C (32 °F to +150 °F) with Internal Barrier I/O Modules (Internal Termination).. Check that the enclosure temperature at the planned mounting location stays inside this band during the hottest period of the operating year.

How much does the Bently Nevada 3500/60-01-00 Temperature Monitor Module - Datasheet, Specs & In Stock weigh?

The documented weight is 0.91 kg (2.0 lb).. Use it for lifting, rail-loading and shipping decisions, and quote it when a handling study is required for the installation.

Related & compatible parts

Bently Nevada · 31000 / 32000 Series

31000-29-10-20-025-02-02

Bently Nevada 31000-29-10-20-025-02-02 Proximity Probe Housing. Fittings: Two 3/4-14 NPT fittings, one plug; O-Ring Material: Neoprene®.

Available on request

Bently Nevada · 3500

3500/61-02-02

Bently Nevada 3500/61-02-02 Temperature Monitors with Recorder Outputs. Bulkhead Rack: ±3 °C at 25 °C (±5.4 °F at…

Available on request

Bently Nevada

106765-04

Genuine Bently Nevada 106765-04 interconnect cable, 4 metres, new and original in factory packing with a 12-month warranty.

In Stock

Bently Nevada · 330903 / 330905 / 330908 Series

330905-05-13-10-02-00

Bently Nevada 330905-05-13-10-02-00 Proximity Probes & Sensors. Connector and Cable Type: Miniature coaxial ClickLoc connector.

Available on request

News & guides for Bently Nevada

View all articles

Request a quote for this part

Part number: 3500/60-01-00

We reply within one business day.

3500/60-01-00 Quote reply within 1 business day