Bently Nevada Vibration Monitoring 3500
Bently Nevada 3500/33-01-00 149992-01
3500/33 16-Channel Relay Module
Bently Nevada 3500/33-01-00 149992-01 3500/33 16-Channel Relay Module. Output Module: 16-Channel Relay Output Module; Suppressor: 250 Vrms.
- Available on request
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Manufacturer | Bently Nevada |
|---|---|
| Product No. | 3500/33-01-00 149992-01 |
| Product type | 3500/33 16-Channel Relay Module |
| Output Module | 01 = 16-Channel Relay Output Module |
| Agency Approval Option | CN = Approvals country specific (CN Approvals Option Quick Reference Guide and Field Notification Letter are in the download section) |
| Operating Temperature | -30 °C to +65 °C (-22 °F to +150 °F) |
| Storage Temperature | -40 °C to +85 °C (-40 °F to +185 °F). |
| Humidity | 95%, non-condensing. |
| Illuminated when the | 3500/33 16-Channel Relay |
| Module is operating | properly. |
| Transmit and receive | flashes when the 3500/3316-Channel Relay |
| Module is communicating | with other modules in the 3500 rack. |
| CH Alarm LED Illuminated when Relay | channel is in an alarm state. |
| Suppressor | 250 Vrms |
| Relay Contact | Life 10,000 cycles |
| Four groups of four channels | are switch selectable for |
| Normally De-energized (ND) | or Normally Energized (NE) operation. |
| Dimensions | (height x width x depth) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) |
| Min Switched | Current 100 mA @ 5 Vdc |
| Power | 70 W @ 24 Vdc 10 W @ 48 Vdc 9 W @ 60 Vdc |
| Voltage 30 Vdc | l Minimum switched load for standard (silver) contacts is 100 mA @ 5 Vdc. l Minimum switched load for Low Current (gold-plated) contacts is 1 mA @ 1 Vdc. |
| Min Switched | Current 1 mA @ 1 Vdc |
| Max Switched | Current 100 mA @ 48 Vdc Specific to AC up to 120VAC: l The Minimum switching current for Gold plated is 1m A l The maximum switching current before damaging the Gold relays is 5m A |
| ATEX and North American zones. | l The Zone 2 standards specify increased spacing requirements at higher voltages. |
Description
The Bently Nevada 3500/33-01-00 149992-01 is a 3500/33 16-channel relay module for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. Dimensions are (height x width x depth) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.
Product Identification
- Manufacturer: Bently Nevada.
- Product No.: 3500/33-01-00 149992-01.
- Product type: 3500/33 16-Channel Relay Module.
Ordering & Configuration
- Agency Approval Option: CN = Approvals country specific (CN Approvals Option Quick Reference Guide and Field Notification Letter are in the download section).
- Four groups of four channels: are switch selectable for.
Electrical & Signal
- CH Alarm LED Illuminated when Relay: channel is in an alarm state..
Environmental Ratings
- Operating Temperature: -30 °C to +65 °C (-22 °F to +150 °F).
- Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)..
- Humidity: 95%, non-condensing..
Physical & Mechanical
- Dimensions: (height x width x depth) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in).
Specifications
- Output Module: 01 = 16-Channel Relay Output Module.
- Illuminated when the: 3500/33 16-Channel Relay.
- Module is operating: properly..
- Transmit and receive: flashes when the 3500/3316-Channel Relay.
- Module is communicating: with other modules in the 3500 rack..
- Suppressor: 250 Vrms.
- Relay Contact: Life 10,000 cycles.
- Normally De-energized (ND): or Normally Energized (NE) operation..
- Min Switched: Current 100 mA @ 5 Vdc.
- Power: 70 W @ 24 Vdc 10 W @ 48 Vdc 9 W @ 60 Vdc.
- Voltage 30 Vdc: l Minimum switched load for standard (silver) contacts is 100 mA @ 5 Vdc. l Minimum switched load for Low Current (gold-plated) contacts is 1 mA @ 1 Vdc..
- Min Switched: Current 1 mA @ 1 Vdc.
- Max Switched: Current 100 mA @ 48 Vdc Specific to AC up to 120VAC: l The Minimum switching current for Gold plated is 1m A l The maximum switching current before damaging the Gold relays is 5m A.
- ATEX and North American zones.: l The Zone 2 standards specify increased spacing requirements at higher voltages..
Model Comparison
Compare the 3500/33-01-00 149992-01 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.
| Model | Product No. | Dimensions | Product type | Agency Approval Option | Power | Manufacturer | Output Module | Operating Temperature |
|---|---|---|---|---|---|---|---|---|
| 3500/33-01-00 149992-01 | 3500/33-01-00 149992-01 | (height x width x depth) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) | 3500/33 16-Channel Relay Module | CN = Approvals country specific (CN Approvals Option Quick Reference Guide and Field Notification Letter are in the download section) | 70 W @ 24 Vdc 10 W @ 48 Vdc 9 W @ 60 Vdc | Bently Nevada | 01 = 16-Channel Relay Output Module | -30 °C to +65 °C (-22 °F to +150 °F) |
| 3500/33-01-00 | 3500/33-01-00 | — | 16-Channel relay module | — | — | Bently Nevada | — | — |
| 3500/33-01-01 | 3500/33-01-01 | (height x widthx depth) 241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) | 3500/33 16-Channel Relay Module | — | — | Bently Nevada | — | — |
| 3500/65-01-00 145988-02 | 3500/65-01-00 145988-02 | (Height x | — | 00 = None | — | Bently Nevada | — | — |
| 3500/15 133292-01 | 3500/15 133292-01 | (Height x width x depth) 120.7 mm x 50.8 mm x 251.5 mm 4.75 in x 2.0 in x 9.9 in | Low Voltage Dc Power Supply Module | — | supply module | Bently Nevada | — | — |
| 3500/50M-01-00 286566-02 | 3500/50M-01-00 286566-02 | (Height x Width x | Tachometer Module | — | consumption 5.8 Watts, typical | Bently Nevada | — | — |
| 3500/92-04-01-01 | 3500/92-04-01-01 | (Height x Width x | — | 01 = CSA/NRTL/C | — | Bently Nevada | — | — |
Frequently asked questions
What is the Bently Nevada 3500/33-01-00 149992-01 and what does it do?
The Bently Nevada 3500/33-01-00 149992-01 is a 3500/33 16-channel relay module for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.
What are the physical dimensions of the 3500/33-01-00 149992-01?
The 3500/33-01-00 149992-01 measures (height x width x depth) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) and weighs It occupies a standard 3500 rack slot and installs on the rack backplane.
How is the 3500/33-01-00 149992-01 installed and configured?
The 3500/33-01-00 149992-01 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.
Related & compatible parts
Bently Nevada · 3500
3500/61-03-02
Bently Nevada 3500/61-03-02 Temperature Monitors with Recorder Outputs. Power Consumption: 3500/61 Nominal consumption of 9 watts.
Bently Nevada · 330903 / 330905 / 330908 Series
330908-00-16-10-02-05
Bently Nevada 330908-00-16-10-02-05 Proximity Probes & Sensors. Connector and Cable Type: Miniature coaxial ClickLoc connector.
Bently Nevada · 31000 / 32000 Series
31000-16-10-00-085-03-02
Bently Nevada 31000-16-10-00-085-03-02 Proximity Probe Housing. Probe Cable Length: 1.0 m (39 in); O-Ring Material: Neoprene®.
Bently Nevada · 330901 / 330902 / 330908 Series
330902-00-47-10-02-05
Bently Nevada 330902-00-47-10-02-05 Proximity Probes & Sensors. Agency Approval: Multiple Approvals; Total Length: 1.0 meter (39 in).
News & guides for Bently Nevada
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Bently Nevada 3500/91 EGD Gateway: Mark VIe Interface, Slots and Limits
TL;DR: The Bently Nevada 3500/91 is the EGD (Ethernet Global Data) communication gateway for a 3500 rack. It publishes rack,…
Bently Nevada 3500/50M Tachometer Module: Channels, Alarms, Spares
The 3500/50M is a two-channel speed module with no onboard relay contacts and no numeric display. What it measures, how…
Bently Nevada Orbit 60 conneX: Bidirectional DCS Interface
Bently Nevada’s Orbit 60 condition monitoring platform connects to the rest of the plant through conneX—a bidirectional digital interface that…
Bently Nevada 3500 Machinery Protection System: Specifications and Configuration
The Bently Nevada 3500 Machinery Protection System is a rack-based, modular monitoring and protection platform for rotating machines such as…
Bently Nevada 3300 XL Proximity Probe: Materials, Ratings, and Mounting
The Bently Nevada 3300 XL proximity transducer system measures radial vibration, axial position, and phase reference on rotating machinery shafts.…
Bently Nevada 32000 Metric Probe Housing: Construction and Protection Ratings
The Bently Nevada 32000 Metric Proximity Probe Housing is a mounting assembly that secures a 3300 XL proximity probe in…