Bently Nevada Vibration Monitoring 3500
Bently Nevada 3500/42M-09-00
3500/42m Proximitor Seismic Monitor
Bently Nevada 3500/42M-09-00 3500/42m Proximitor Seismic Monitor. Transducer Type: Prox/Accel, Velomitor or HTVS; Output Impedance: 550 Ω.
- Available on request
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Manufacturer | Bently Nevada |
|---|---|
| Product No. | 3500/42M-09-00 |
| Product type | 3500/42m Proximitor Seismic Monitor |
| I/O Description | Prox/Velom I/O Module with internal terminations ; |
| Transducer Type | Prox/Accel, Velomitor or HTVS |
| Signal | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| Power consumption | 7.7 watts, typical |
| Standard I/O | 10 kΩ (Proximitor and acceleration inputs) |
| Sensitivity | Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) |
| Thrust | 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) |
| Eccentricity | 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) |
| Differential Expansion | 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) REBAM ; 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil) |
| Acceleration & Acceleration2 | 10 mV/ (m/s2) (100 mV/g) |
| OK LED | Indicates when the 3500/42M Proximitor Seismic Monitor is operating properly. |
| TX/RX LED | Indicates when the 3500/42M Proximitor Seismic Monitor is communicating with other modules in the 3500 rack. |
| Bypass LED | Indicates when the 3500/42M Proximitor Seismic Monitor is in Bypass Mode. |
| Buffered Transducer Outputs | The front of each monitor has one coaxial connector for each channel. |
| Output Impedance | 550 Ω |
| Transducer Power Supply | -24 Vdc |
| Resolution | 0.3662 µA per bit ±0.25% error at room temperature ±0.7% error over temperature range |
| Shaft Absolute Buffered Outputs | The Shaft Absolute I/O modules have one output for each channel group. |
| Shaft Absolute Output Impedance | 300 Ω |
| Signal Conditioning | Specified at +25 ºC (+77 ºF) unless otherwise noted. |
| Direct filter | User-programmable Single-pole -3db at 4 Hz to 4000 Hz or 1 Hz to 600 Hz ± 1% accuracy |
| Gap filter | -3 dB at 0.09 Hz |
| Not 1X filter | 60 cpm to 15.8 times running speed Constant Q notch filter Minimum rejection in stopband of -34.9 dB |
| Smax | 0.125 to 15.8 times running speed 1X and 2X vector filter: Constant Q Filter Minimum rejection in stopband of -57.7 dB |
| Direct and Gap | Exclusive of filtering Within ±0.33% of full-scale typical ±1% maximum 1X and 2X: Within ±0.33% of full-scale typical ±1% maximum |
| Smax | Within ±5% maximum |
| Not 1X | ±3% for machine speeds less than 30,000 cpm ±8.5% for machine speeds greater than 30,000 cpm |
| Accuracy | Within ±0.33% of full-scale typical ±1% maximum |
| Direct filter | -3 dB at 1.2 Hz |
| Gap filter | -3 dB at 0.41 Hz |
| Direct filter | -3 dB at 15.6 Hz |
| Accuracy | Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters |
| High-pass | 4-pole (80 dB per decade, 24 dB per octave) |
| Low-pass | 4-pole (80 dB per decade, 24 dB per octave) |
| Accuracy | Within ± 0.33% of full scale typical ± 1% maximum Exclusive of filters |
| Bias filter | -3 dB at 0.01 Hz |
| Not OK filter | -3 dB at 2400 Hz 1X and 2X vector filter: Valid for machine speeds of 60 cpm to 100,000 cpm |
| Accuracy | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: |
| Full Scale 0-0.5 | ±3% typical |
| Full Scale 0-1.0 | ±2% typical |
| Full Scale 0-2.0 | ±1% typical |
| Velomitor sensor accuracy with barriers | Under radiated immunity conditions, add ± 11% for all full scale ranges. The total Velomitor sensor accuracy will be ± 15%. |
| Bias | -3dB at 0.01 Hz ; Velocity II only |
| Not OK filter | -3 dB at 40 Hz; Velocity II only |
| RMS | 10 to 5,500 Hz, -3 dB |
| Peak or peak to-peak | 3 to 5,500 Hz, -3 dB 1X and 2X vector filter: Valid for machine speeds of 60 to 100,000 cpm Velocity II only |
| Low-pass | 2-pole (40 dB per decade, 12 dB per octave) |
| Dimensions | (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in) |
Description
The Bently Nevada 3500/42M-09-00 is a 3500/42m proximitor seismic monitor for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against programmable alarm setpoints inside the 3500 rack. Dimensions are (height x widthx depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in) It monitors critical rotating equipment such as turbines, compressors, and pumps, and communicates monitor status and measured values to the 3500 rack and to recorder outputs for machinery protection. Configuration is performed with 3500 Rack Configuration Software; no field calibration is required.
Product Identification
- Manufacturer: Bently Nevada.
- Product No.: 3500/42M-09-00.
- Product type: 3500/42m Proximitor Seismic Monitor.
Electrical & Signal
- Power consumption: 7.7 watts, typical.
- Output Impedance: 550 Ω.
- Resolution: 0.3662 µA per bit ±0.25% error at room temperature ±0.7% error over temperature range.
- Shaft Absolute Output Impedance: 300 Ω.
- Signal Conditioning: Specified at +25 ºC (+77 ºF) unless otherwise noted..
- Accuracy: Within ±0.33% of full-scale typical ±1% maximum.
- Accuracy: Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters.
- Accuracy: Within ± 0.33% of full scale typical ± 1% maximum Exclusive of filters.
- Accuracy: Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy:.
- Velomitor sensor accuracy with barriers: Under radiated immunity conditions, add ± 11% for all full scale ranges. The total Velomitor sensor accuracy will be ± 15%..
Physical & Mechanical
- Dimensions: (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in).
Specifications
- I/O Description: Prox/Velom I/O Module with internal terminations ;.
- Transducer Type: Prox/Accel, Velomitor or HTVS.
- Signal: Accepts from 1 to 4 proximity, velocity or acceleration transducer signals.
- Standard I/O: 10 kΩ (Proximitor and acceleration inputs).
- Sensitivity: Radial Vibration: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
- Thrust: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
- Eccentricity: 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil).
- Differential Expansion: 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) REBAM ; 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil).
- Acceleration & Acceleration2: 10 mV/ (m/s2) (100 mV/g).
- OK LED: Indicates when the 3500/42M Proximitor Seismic Monitor is operating properly..
- TX/RX LED: Indicates when the 3500/42M Proximitor Seismic Monitor is communicating with other modules in the 3500 rack..
- Bypass LED: Indicates when the 3500/42M Proximitor Seismic Monitor is in Bypass Mode..
- Buffered Transducer Outputs: The front of each monitor has one coaxial connector for each channel..
- Transducer Power Supply: -24 Vdc.
- Shaft Absolute Buffered Outputs: The Shaft Absolute I/O modules have one output for each channel group..
- Direct filter: User-programmable Single-pole -3db at 4 Hz to 4000 Hz or 1 Hz to 600 Hz ± 1% accuracy.
- Gap filter: -3 dB at 0.09 Hz.
- Not 1X filter: 60 cpm to 15.8 times running speed Constant Q notch filter Minimum rejection in stopband of -34.9 dB.
- Smax: 0.125 to 15.8 times running speed 1X and 2X vector filter: Constant Q Filter Minimum rejection in stopband of -57.7 dB.
- Direct and Gap: Exclusive of filtering Within ±0.33% of full-scale typical ±1% maximum 1X and 2X: Within ±0.33% of full-scale typical ±1% maximum.
- Smax: Within ±5% maximum.
- Not 1X: ±3% for machine speeds less than 30,000 cpm ±8.5% for machine speeds greater than 30,000 cpm.
- Direct filter: -3 dB at 1.2 Hz.
- Gap filter: -3 dB at 0.41 Hz.
- Direct filter: -3 dB at 15.6 Hz.
- High-pass: 4-pole (80 dB per decade, 24 dB per octave).
- Low-pass: 4-pole (80 dB per decade, 24 dB per octave).
- Bias filter: -3 dB at 0.01 Hz.
- Not OK filter: -3 dB at 2400 Hz 1X and 2X vector filter: Valid for machine speeds of 60 cpm to 100,000 cpm.
- Full Scale 0-0.5: ±3% typical.
- Full Scale 0-1.0: ±2% typical.
- Full Scale 0-2.0: ±1% typical.
- Bias: -3dB at 0.01 Hz ; Velocity II only.
- Not OK filter: -3 dB at 40 Hz; Velocity II only.
- RMS: 10 to 5,500 Hz, -3 dB.
- Peak or peak to-peak: 3 to 5,500 Hz, -3 dB 1X and 2X vector filter: Valid for machine speeds of 60 to 100,000 cpm Velocity II only.
- Low-pass: 2-pole (40 dB per decade, 12 dB per octave).
Model Comparison
Compare the 3500/42M-09-00 against the closest Bently Nevada configurations below to confirm ordering options, ratings and physical interchange.
| Model | Product No. | Product type | Accuracy | Low-pass | Transducer Type | I/O Description | Manufacturer | Signal |
|---|---|---|---|---|---|---|---|---|
| 3500/42M-09-00 | 3500/42M-09-00 | 3500/42m Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | Prox/Accel, Velomitor or HTVS | Prox/Velom I/O Module with internal terminations ; | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42M-01-00 | 3500/42M-01-00 | Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | Seismoprobe Prox/Accel and Velomitor are supported but are not recommended. | Prox/Seismic I/O Module with internal terminations | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42M 140734-02 | 140734-02 | 3500/42m Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters | 4-pole (80 dB per decade, 24 dB per octave) | — | — | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42M 176449-02 | 176449-02 | 3500/42m Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | — | — | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42-02-00 | 3500/42-02-00 | Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | Seismoprobe Prox/Accel and Velomitor are supported but are not recommended. | Seismoprobe Prox/Accel and Velomitor are supported but are not recommended. | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42-04-00 | 3500/42-04-00 | Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | Prox/Accel on channels 1 through 4 | — | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
| 3500/42-06-00 | 3500/42-06-00 | Proximitor Seismic Monitor | Within ±0.33% of full-scale typical ±1% maximum +1% -3% with MTL 764(-) Zener External Barrier Exclusive of filters Velomitor sensor accuracy: | 2-pole (40 dB per decade, 12 dB per octave) | Prox/Accel on channels 1 through 4 | — | Bently Nevada | Accepts from 1 to 4 proximity, velocity or acceleration transducer signals |
Frequently asked questions
What is the Bently Nevada 3500/42M-09-00 and what does it do?
The Bently Nevada 3500/42M-09-00 is a 3500/42m proximitor seismic monitor for the 3500 Machinery Protection System. It conditions field transducer signals into vibration and position measurements and compares them against user-programmable alarm setpoints within the 3500 rack.
What are the physical dimensions of the 3500/42M-09-00?
The 3500/42M-09-00 measures (Height x Widthx Depth) 241.3 mm x 24.4 mm x 241.8mm (9.50 in x 0.96 in x 9.52 in) and weighs It occupies a standard 3500 rack slot and installs on the rack backplane.
How is the 3500/42M-09-00 installed and configured?
The 3500/42M-09-00 mounts in a 3500 rack rear slot and draws power from the rack backplane. Channels are configured with 3500 Rack Configuration Software; alarm setpoints and full-scale ranges are set in software with no field calibration required.
Related & compatible parts
Bently Nevada · 31000 / 32000 Series
32000-29-05-10-075-07-02
Bently Nevada 32000-29-05-10-075-07-02 Proximity Probe Housing. Probe Penetration: 75 mm; Standoff Adapter: 100 mm.
Bently Nevada · 31000 / 32000 Series
31000-28-10-00-087-03-02
Bently Nevada 31000-28-10-00-087-03-02 Proximity Probe Housing. Fittings: Two plugs, one 3/4-14 NPT fitting; O-Ring Material: Neoprene®.
Bently Nevada · 3500
3500/72-01-00
Bently Nevada 3500/72-01-00 3500 System Module. Input: Impedance 10 kΩ; Power: Consumption 7.7 watts, nominal.
Bently Nevada
3500/15-05-05-02
Bently Nevada 3500/15-05-05-02 AC and DC Power Supply Module. Agency Approval: ATEX / IECEx / CSA (Class 1,…
News & guides for Bently Nevada
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…
Bently Nevada 3500/91 EGD Gateway: Mark VIe Interface, Slots and Limits
TL;DR: The Bently Nevada 3500/91 is the EGD (Ethernet Global Data) communication gateway for a 3500 rack. It publishes rack,…
Bently Nevada 3500/50M Tachometer Module: Channels, Alarms, Spares
The 3500/50M is a two-channel speed module with no onboard relay contacts and no numeric display. What it measures, how…
Bently Nevada Orbit 60 conneX: Bidirectional DCS Interface
Bently Nevada’s Orbit 60 condition monitoring platform connects to the rest of the plant through conneX—a bidirectional digital interface that…
Bently Nevada 3500 Machinery Protection System: Specifications and Configuration
The Bently Nevada 3500 Machinery Protection System is a rack-based, modular monitoring and protection platform for rotating machines such as…
Bently Nevada 3300 XL Proximity Probe: Materials, Ratings, and Mounting
The Bently Nevada 3300 XL proximity transducer system measures radial vibration, axial position, and phase reference on rotating machinery shafts.…
Bently Nevada 32000 Metric Probe Housing: Construction and Protection Ratings
The Bently Nevada 32000 Metric Proximity Probe Housing is a mounting assembly that secures a 3300 XL proximity probe in…