Lenze EVF9381-EV
Frequency inverter
Genuine surplus Lenze EVF9381-EV frequency inverter: 250 kW, 500 A nominal, 150% overload for 60 s. Verified condition and practical sourcing support from Autronexa.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Rated motor power | 250 kW (4-pole asynchronous motor, 3 AC 400 V) |
|---|---|
| Output current | 500 A nominal at 2 kHz chopper frequency |
| Max. output current | 750 A maximum for 60 s |
| Overload | 150% rated torque for 60 s |
| Supply voltage | 3/PE AC 340 to 456 V nominal, 45 to 65 Hz |
| Chopper frequency | Adjustable 1, 2 or 4 kHz |
| Power loss | 6.6 kW |
| Protection rating | IP20 |
| Weight | 320 kg |
Description
The Lenze EVF9381-EV is a Frequency inverter for industrial control and automation applications.
The Lenze EVF9381-EV is a three-phase frequency inverter from the 9300 vector series, rated 250 kW for a 4-pole asynchronous motor on 3 AC 400 V. It delivers 500 A nominal output current at 2 kHz chopper frequency and 750 A maximum for 60 s, with 150% rated torque for 60 s. Autronexa supplies genuine surplus and refurbished units with verified condition.
What buyers should know about this drive
This model is a high-power drive built as two units — master and slave — connected in parallel, so the output currents listed are total currents of both units. Control options include U/f characteristic control (linear/square), vector control and sensorless speed control. The chopper frequency is adjustable to 1, 2 or 4 kHz. Cooling is by internal fan with airflow from bottom to top, and the protection rating is IP20. The unit weighs 320 kg and measures 1145 × 1050 × 436 mm (H×W×D).

How does this drive fit into existing systems?
The inverter provides an AIF automation interface (X1) for a pluggable fieldbus module and a system bus CAN (X4). No fieldbus module is integrated as standard; communication expansion relies on the pluggable module on X1. Supported fieldbus modules per official Lenze product information include LECOM-A/B, PROFIBUS DP, CANopen, DeviceNet, INTERBUS and LON. The supply voltage range is 3/PE AC 340 to 456 V nominal, 45 to 65 Hz. Operating temperature is 0 to +50 °C and storage temperature is -20 to +60 °C. Power loss is 6.6 kW.

Why choose genuine surplus for this Lenze drive?
Lenze lists the 9300 series within its i950 migration set, and there is no drop-in same-order-code replacement. For maintenance teams keeping existing machinery running, a verified surplus or refurbished this drive can be a practical alternative to redesigning the drive arrangement. Autronexa verifies units against OEM datasheet markings and part-number cross-reference, and refurbished units are tested against OEM datasheet specifications and functionally verified by our sourcing team. This approach supports genuine parts, verified, with clear lead times compared with sourcing a new drive generation.
Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the Lenze EVF9381-EV a genuine unit or a clone?
Autronexa verifies every Lenze EVF9381-EV against OEM datasheet markings and part-number cross-reference. We supply genuine surplus and refurbished units, not grey-market copies.
What condition will the EVF9381-EV arrive in?
The Lenze EVF9381-EV is supplied as refurbished by default, tested against OEM datasheet specifications and functionally verified by our sourcing team. Surplus units are also available depending on stock.
How fast can Autronexa ship the EVF9381-EV?
Lead time for the Lenze EVF9381-EV depends on current stock and condition. Contact Autronexa with your part number to confirm verified condition and current availability.
Does the EVF9381-EV support fieldbus communication?
The Lenze EVF9381-EV has an AIF automation interface (X1) for a pluggable fieldbus module and a system bus CAN (X4). No fieldbus module is integrated as standard, so the required module must be specified separately.
Is the Lenze EVF9381-EV still supported by Lenze?
Lenze lists the 9300 series within its i950 migration set and there is no drop-in same-order-code replacement. Please verify current lifecycle status and availability with Autronexa before ordering.
Related & compatible parts
Lenze
ESMD371L4TXA
Genuine surplus Lenze ESMD371L4TXA motor control module rated 0.37 kW, 230 V AC, with Modbus and LECOM protocols.…
Lenze
EMF2102IBCV001
Genuine surplus Lenze EMF2102IBCV001 AIF module adds RS232 LECOM-A serial communication to 8200 vector and 93XX drive controllers.
Lenze
E82EV113-4C
Genuine surplus Lenze E82EV113-4C frequency inverter, 11.0 kW, 400 V class. Verified condition, practical lead times, and sourcing…
Lenze
E82CV751K4C
Genuine surplus Lenze E82CV751K4C cold-plate inverter: 0.75 kW, 2.4 A, IP20, with verified condition and practical sourcing support.
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Bently Nevada 3500/20 RIM: Slot 1, I/O Modules, OK Relay
Why the Bently Nevada 3500/20 RIM must sit in slot 1, how its RS-232/RS-422, modem and Data Manager I/O modules…
ABB Startup Challenge China 2026: What Wasome’s Win Signals
ABB named Wasome winner of its first China Startup Challenge in October 2026 with a CNY 200,000 prize. What the…
Honeywell Forge Cognition: Reading the Pilot Numbers
The 90% alarm cut and 10% energy figure come from one Voyager pilot, not six sites. What Honeywell's Forge Cognition…