Lenze I/O & Function Modules

Lenze E82CV751K4C

Replaced by a bare metal cooling plate connected to a separate customer-side

Manufacturer: Lenze Part Number: E82CV751K4C

Genuine surplus Lenze E82CV751K4C cold-plate inverter: 0.75 kW, 2.4 A, IP20, with verified condition and practical sourcing support.

Call us

Availability & pricing

Pricing is available on request — send an RFQ for a same-day quote.

5-15 days

Technical specifications

Rated motor power 0.75 kW typical (4-pole three-phase asynchronous motor)
Rated output current 2.4 A nominal at 8 kHz switching frequency
Max. output current 3.6 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir)
Supply voltage 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz
Built-in ports X3 control terminal strip (analog/digital I/O)
Communication expansion FIF slot for plug-in function modules (E82ZAF* family)
Operating temperature -10 … +55 °C (derated by 2.5%/°C above +40 °C)
Protection rating IP20

Description

The Lenze E82CV751K4C is a frequency inverter from the 8200 vector series in cold-plate technology, rated for 0.75 kW typical motor power and 2.4 A nominal output current at 8 kHz. Engineers choose genuine surplus or refurbished units when OEM lead times stretch, because the cold-plate design supports direct cooling integration. Autronexa verifies each unit against OEM datasheet markings before dispatch.

What the Cold-Plate Design Means for Your Panel

this unit replaces the standard heatsink with a bare metal cooling plate connected to a separate customer-side cooler. This arrangement suits enclosures where airflow is restricted or where heat must be routed away from sensitive electronics. The plate carries a dissipated power loss of 40 W and a thermal resistance Rth ≤ 1.0 K/W between cooler and cooling medium. Maximum permissible cooling-plate temperature is 75 °C, so your external cooling circuit must hold the plate below that limit. The inverter accepts a 3/PE AC supply from 320 V to 550 V at 45 to 65 Hz, covering common industrial voltages without a step transformer. Built-in control is V/f characteristic (linear or quadratic) and sensorless vector control, with an output frequency range of -650 to +650 Hz. An integrated brake transistor simplifies stopping high-inertia loads.

Figure 1: Front view of the Lenze E82CV751K4C Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

I/O, Communication, and Environmental Limits

The X3 control terminal strip provides 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, and 1 relay output with a changeover contact rated 250 V AC / 3 A. No fieldbus protocol is built in; the FIF slot accepts plug-in function modules from the E82ZAF* family when network connectivity is required. For overload events, the inverter delivers 3.6 A for 60 s, following a periodic load cycle of 1 minute at Imax and 2 minutes at 75% of rated current. Operating temperature is -10 to +55 °C with derating of 2.5%/°C above +40 °C, and storage temperature is -25 to +60 °C. The IP20 protection rating suits cabinet mounting, and relative humidity should average 85% RH without condensation (climatic class 3K3 per EN 50178).

Figure 2: Technical layout and connection details for the Lenze E82CV751K4C Replaced by a bare metal cooling plate connected to a separate customer-side.

Sourcing a Legacy Cold-Plate Inverter

Lenze lists the 8200 vector among its previous products, and the cold-plate special design is available on request. No drop-in same-order-code replacement exists, although Lenze documents a migration path to the i950 using an i950 PROFIBUS module and the L_ICIP library. For maintenance teams keeping existing machines running, a genuine surplus or refurbished this unit is often the practical route. Autronexa supplies tested units with clear condition notes and practical lead times. Contact Autronexa with your part number for verified condition and current availability.

Frequently asked questions

Is the Lenze E82CV751K4C a genuine Lenze unit or a clone?

Autronexa verifies each E82CV751K4C against OEM datasheet markings and part-number cross-references before listing. Units are genuine surplus or professionally refurbished, not grey-market copies.

What condition will the Lenze E82CV751K4C arrive in?

The E82CV751K4C is supplied as refurbished unless otherwise stated. Each unit is tested against OEM datasheet specifications and functionally verified by our sourcing team before dispatch.

How fast can Autronexa ship the E82CV751K4C?

Lead time depends on current stock. Contact Autronexa for the present lead time on the E82CV751K4C; surplus and refurbished units are typically ready to ship once verified.

Does the E82CV751K4C include a built-in fieldbus port?

No. The E82CV751K4C has no built-in fieldbus protocol. Network connectivity requires a plug-in function module from the E82ZAF* family in the FIF slot.

Is the Lenze E82CV751K4C still supported by Lenze?

Lenze lists the 8200 vector series among its previous products, and the cold-plate design is available on request. Contact Autronexa to verify OEM support status and migration options for the E82CV751K4C.

Related & compatible parts

Lenze

ESMD371L4TXA

Genuine surplus Lenze ESMD371L4TXA motor control module rated 0.37 kW, 230 V AC, with Modbus and LECOM protocols.…

In Stock

Lenze

E94ASHE0074

Genuine surplus Lenze E94ASHE0074 axis module, 3 kW, CANopen on board. Verified condition and practical sourcing support from…

In Stock

Lenze

E82CV402K4C

Genuine surplus Lenze E82CV402K4C cold-plate inverter: 4.0 kW, 9.5 A, 320–550 V AC, IP20. Verified condition and practical…

In Stock

Lenze

ESMD113L4TXA

Genuine surplus Lenze ESMD113L4TXA frequency inverter: 11 kW, 400 VAC 3-phase, 27 A, PID control. Verified condition and…

In Stock

News & guides for Lenze

View all articles

Request a quote for this part

Part number: E82CV751K4C

We reply within one business day.

E82CV751K4C Quote reply within 1 business day