Lenze EVS9324-ETV907
Drive 9300 Servo PLC Technology
Genuine surplus Lenze EVS9324-ETV907 Servo PLC drive, 3.0 kW, verified and ready to ship from Autronexa.
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
Technical specifications
| Rated motor power | 3.0 kW (4-pole asynchronous motor, 400 V) |
|---|---|
| Rated output current | 7.0 A nominal at 8 kHz switching frequency |
| Maximum output current | 10.5 A at 8 kHz switching frequency |
| Analog inputs | 2, +/-10 V (switchable 0...20 mA), 11 bits + sign |
| Digital inputs | 6 (1 controller enable + 5 freely assignable), PLC level per IEC 61131-2 |
| Digital outputs | 4, 50 mA per output |
| Encoder input | Multi-encoder input for TTL/SinCos incremental encoders and Hiperface absolute encoders |
| Protocols | CANopen (integrated system bus) |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 350×97×250 mm |
Description
The Lenze EVS9324-ETV907 is a Drive 9300 Servo PLC Technology for industrial control and automation applications.
The Lenze EVS9324-ETV907 is a Global Drive 9300 Servo PLC Technology inverter rated at 3.0 kW for a 4-pole asynchronous motor at 400 V. Maintenance and procurement teams choose genuine surplus or refurbished units of this model to replace failed drives without waiting on OEM lead times. Autronexa verifies each unit against OEM datasheet markings before it ships.
What this drive Delivers on the Floor
This drive runs field-oriented servo control for synchronous and asynchronous servo motors and standard asynchronous motors. Its rated output current is 7.0 A nominal at 8 kHz switching frequency, with a maximum output current of 10.5 A at the same frequency in overload mode. The built-in PLC capability comes from 655 kByte flash program memory, so local logic can run alongside the drive function. For feedback, a resolver input on a Sub-D 9-pin connector and a multi-encoder input for TTL/SinCos incremental encoders and Hiperface absolute encoders cover common servo arrangements. The unit also provides two analog inputs at +/-10 V (switchable 0…20 mA) with 11 bits plus sign, two analog outputs at 9 bits plus sign, six digital inputs (one controller enable plus five freely assignable) at PLC level per IEC 61131-2, and four digital outputs at 50 mA each.

Why Genuine Surplus Fits This Drive
Lenze lists the 9300 series on its previous-products page, and the official migration path to the i950 requires a compatibility switch, a PROFIBUS module, or the L_ICIP library rather than a drop-in same-order-code replacement. That makes verified surplus and refurbished this drive units a practical route for keeping existing machines running. Autronexa sources genuine units and checks condition before dispatch. The CANopen system bus on port X4 and the AIF automation interface on port X1 for a keypad or attachable communication module remain part of the delivered configuration. Because the 9300 family is legacy, buyers should confirm the exact revision and any attached module needs with our sourcing team.

Sourcing Checks Before You Order
Confirm the model code and software variant V907 match your application. Verify the supply arrangement: 3/PE AC 320…528 V nominal at 45…65 Hz, or the alternative DC supply of 460…740 V. Check the ambient conditions, since the operating range is 0…+55 °C with output-current derating of 2.5%/°C above +40 °C, and the IP20 protection rating suits cabinet mounting. The built-in/push-through design measures 350×97×250 mm and weighs 5.0 kg. Share your part number with Autronexa and we will confirm verified condition and current availability.
Frequently asked questions
Is the Lenze EVS9324-ETV907 a genuine Lenze unit or a clone?
Autronexa verifies each Lenze EVS9324-ETV907 against OEM datasheet markings and part-number cross-reference before it is listed. Units are genuine surplus or refurbished stock, not copies.
What condition will the EVS9324-ETV907 arrive in?
The Lenze EVS9324-ETV907 is supplied as refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa for the current condition grade of available units.
How fast can Autronexa ship the EVS9324-ETV907?
Lead time for the Lenze EVS9324-ETV907 depends on current stock. Contact Autronexa with your part number to confirm verified condition and current availability.
Does the EVS9324-ETV907 support CANopen?
Yes. The Lenze EVS9324-ETV907 includes a CAN system bus on port X4 with integrated CANopen protocol, plus an AIF automation interface on port X1 for a keypad or attachable communication module.
Related & compatible parts
Lenze
E84AVSCE7512SX0
Genuine surplus Lenze E84AVSCE7512SX0 AC drive from the 8400 series, verified and ready to ship with technical sourcing…
Lenze
EVF9382-EVV110
Genuine surplus Lenze EVF9382-EVV110 9300 vector inverter, 315 kW with integrated RFI filter class A and brake transistor,…
Lenze
E82CV302K2C
Genuine surplus Lenze E82CV302K2C cold-plate inverter: 3.0 kW, 12.0 A, IP20 — verified condition and practical sourcing support…
Lenze
EME9364-E
Genuine surplus Lenze EME9364-E power supply module: 74 A, 100–550 VAC, 50 kW rated output. Verified condition and…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Bently Nevada 3500/20 RIM: Slot 1, I/O Modules, OK Relay
Why the Bently Nevada 3500/20 RIM must sit in slot 1, how its RS-232/RS-422, modem and Data Manager I/O modules…
ABB Startup Challenge China 2026: What Wasome’s Win Signals
ABB named Wasome winner of its first China Startup Challenge in October 2026 with a CNY 200,000 prize. What the…
Honeywell Forge Cognition: Reading the Pilot Numbers
The 90% alarm cut and 10% energy figure come from one Voyager pilot, not six sites. What Honeywell's Forge Cognition…