Lenze E82CV302K2C
Replaced by a bare metal cooling plate connected to a separate customer-side
Genuine surplus Lenze E82CV302K2C cold-plate inverter: 3.0 kW, 12.0 A, IP20 — verified condition and practical sourcing support from Autronexa.
- 12 Month
- Refurbished
- In Stock
Availability & pricing
Pricing is available on request — send an RFQ for a same-day quote.
5-15 days
Technical specifications
| Rated motor power | 3.0 kW typical (4-pole three-phase asynchronous motor) |
|---|---|
| Rated output current | 12.0 A nominal at 8 kHz switching frequency |
| Max. output current | 18.0 A for 60 s (1 min overload at Imax / 2 min base load at 75% Ir) |
| Supply voltage | 3/PE AC 100 V -0% … 264 V +0%; 45 … 65 Hz |
| Built-in ports | X3 control terminal strip (analog/digital I/O) |
| Protocols | None built-in (fieldbus requires plug-in function module) |
| Communication expansion | FIF slot for plug-in function modules (E82ZAF* family) |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Protection rating | IP20 |
Description
The Lenze E82CV302K2C is a 3.0 kW 8200 vector frequency inverter built in cold-plate technology, where a bare metal cooling plate replaces the heatsink for connection to a separate customer-side cooler. Maintenance and procurement teams specify it when a standard air-cooled drive will not suit the enclosure or thermal layout, and genuine surplus stock keeps that replacement practical. The 12.0 A nominal output at 8 kHz switching frequency and 18.0 A short-time current for 60 s cover typical 4-pole asynchronous motor loads without oversizing the drive. Because the cooling plate carries a thermal resistance of Rth ≤ 0.23 K/W and a maximum permissible plate temperature of 75 °C, the customer-side cooler design directly sets the usable continuous output — undersizing that loop is the most common cause of thermal derating in service. V/f characteristic control (linear or quadratic) and sensorless vector control let you match starting torque to the load, while the -650 … +650 Hz output frequency range supports applications beyond simple fixed-speed duty. ## Surplus Advantage for Legacy Cold-Plate Drives The 8200 vector family sits on Lenze’s official previous-products list, and the cold-plate special design is available on request rather than from open catalogue stock. That status changes the sourcing calculation: a like-for-like same-order-code replacement is not offered, and the documented migration path to the i950 requires a different platform plus engineering effort. Keeping a verified E82CV302K2C on the shelf therefore protects an existing panel from a forced redesign. Autronexa supplies this model as genuine surplus and refurbished stock, tested against OEM datasheet specifications and functionally verified by our sourcing team. The practical result is a shorter route to a working drive than a migration project, with the authenticity of the unit confirmed before dispatch. ## What to Check Before You Order Four points decide whether a cold-plate unit fits your panel. First, confirm the supply: 3/PE AC 100 V -0% … 264 V +0% at 45 … 65 Hz, so verify your site voltage and frequency before committing. Second, confirm the thermal loop — the separate cooler must hold the plate within the 75 °C limit at your duty cycle, since the 110 W dissipated power loss has to leave through that path. Third, confirm the control interface: the X3 terminal strip provides analog and digital I/O, but no fieldbus protocol is built in, so network control needs a plug-in function module in the FIF slot (E82ZAF* family). Fourth, confirm the environment: IP20 protection and an operating range of -10 … +55 °C, derated by 2.5 %/°C above +40 °C, suit cabinet mounting rather than exposed locations. Please verify current lifecycle status and availability with Autronexa before ordering.


Frequently asked questions
Is this a genuine Lenze E82CV302K2C, or a clone?
Autronexa verifies every unit against OEM datasheet markings and part-number cross-reference before it is listed. The E82CV302K2C is supplied as genuine surplus or refurbished stock, and the cold-plate configuration is confirmed against the 8200 vector documentation.
What condition will the E82CV302K2C arrive in?
Units are supplied refurbished as standard, tested against OEM datasheet specifications and functionally verified by our sourcing team. Contact Autronexa with your part number to confirm the condition grade of current stock.
How fast can you ship the E82CV302K2C?
Lead time depends on current stock, so contact Autronexa for verified availability and a clear dispatch date. Surplus and refurbished units already on the shelf usually move faster than a factory-order route.
Does the E82CV302K2C need a separate cooler to run?
Yes. The heatsink is replaced by a bare metal cooling plate connected to a customer-side cooler. The plate must stay within the 75 °C limit, and the thermal resistance of Rth ≤ 0.23 K/W between cooler and cooling medium sets how much heat the loop can remove.
Can the E82CV302K2C connect to a fieldbus network?
No protocol is built in. Fieldbus communication requires a plug-in function module in the FIF slot, from the E82ZAF* family. Confirm the required module and cabling with your supplier before commissioning.
Related & compatible parts
Lenze
EVS9323-CKV003
Genuine surplus Lenze EVS9323-CKV003 cam profiler drive: 1.5 kW, 3.9 A, cold-plate design, CANopen. Verified condition and practical…
Lenze
E94ASHE0074
Genuine surplus Lenze E94ASHE0074 axis module, 3 kW, CANopen on board. Verified condition and practical sourcing support from…
Lenze
E70ACMDE0204SA2ETR
Genuine surplus Lenze E70ACMDE0204SA2ETR double-axis servo inverter with EtherCAT, STO safety and 20 A max output per axis.
Lenze
E84AVTCE5524SB0
Genuine surplus Lenze E84AVTCE5524SB0 frequency inverter: 5.50 kW, STO safety, CANopen. Verified condition and practical sourcing support from…
News & guides for Lenze
Lenze spare parts: buying guide, series overview and how to order
Lenze spare parts buying guide: 4 parts online, popular series, condition options and how our RFQ process works.
Intel Offers Korean AI Chip Firms Custom Design, Packaging and Foundry Routes
Intel used its own Seoul summit to offer Korean AI chip companies custom silicon, advanced packaging and foundry routes. No…
Bently Nevada AnomAlert: Motor Anomaly Detection Without Sensors
TL;DR: The Bently Nevada AnomAlert is a motor anomaly detector that watches a three-phase motor through its voltage and current…
Motion Control Precision: Servo Loops, Fieldbus Jitter, AI
Motion control precision depends on servo loop rates, fieldbus cycle times and jitter, sensor latency and mechanics. AI sits above…
Omron C6 Servo Launches in Europe: What Changes for 1S and Spares
Omron's C6 servo launched in Europe on 7 October 2026 with a 26-bit encoder, 3.5 kHz response and STO. What…
Orbit 60 PPM (142M8515): What the Module Does and What the 90% Load Warning Means
TL;DR: The Bently Nevada Orbit 60 Protection Processing Module (PPM) is the centralized compute engine of the protection system: it…
Schneider Electric Product Carbon Footprint Data: What Engineers Can Look Up
TL;DR: Schneider Electric publishes product-level carbon data, but not through a single system. Product pages carry a “total life cycle…
Bently Nevada 3500/06 Weatherproof Housing: Ratings, Purging and Mounting Limits
TL;DR: The weatherproof enclosure for a Bently Nevada 3500 rack is the 3500/06, not the 3500/01 — 3500/01 is the…